Linear AE1000Plus Optional Postal Lock, Postal Lock Installation, Camera Installation

Page 13

Optional Postal Lock

A postal lock can be installed in the AE1000Plus Entry System to provide keyed access for the postal service. The AE1000Plus case is designed to accept a U.S. Postal Service postal lock. When the postal lock is engaged, the programmed output relay will activate.

Postal Lock Installation

1.Remove the four locknuts that retain the postal lock switch plate (above the speaker on the AE1000Plus faceplate).

2.Remove the switch plate, hole cover plate and block from the four studs. The hole cover plate and block will not be used and can be discarded.

3.Install the postal lock assembly onto the four studs. The postal lock’s moving plunger should point towards the middle of the faceplate (see fi gure).

4.Replace the postal lock switch plate with the microswitch oriented inward where it will be pressed by the postal lock’s moving plunger (see fi gure).

5.Secure the postal lock and switch plate with the four locknuts.

NOTE: Be sure the postal lock’s plunger actuates the microswitch. Adjust the switch plate and the postal lock then test the action until the microswitch fully actuates.

1REMOVE LOCKNUTS

3INSTALL POSTAL LOCK

PLUNGER POINTS

TO LEFT

2REMOVE PLATE

4REPLACE PLATE WITH THE MICROSWITCH TOWARDS THE FRONT OF THE CABINET, REPLACE LOCKNUTS

6.Tighten the four locknuts after the adjustment and testing is complete.

7.When programming the system, set the postal lock option to activate the desired relay output.

NOTE: BE SURE THE POSTAL LOCK'S PLUNGER ACTUATES THE MICROSWITCH. ADJUST THE SWITCH PLATE AND THE POSTAL LOCK THEN TEST THE ACTION UNTIL THE MICROSWITCH FULLY ACTUATES

Optional Color CCTV Camera

Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed inside the AE1000Plus Entry System. The camera provides a video signal for viewing the area in front of the entry system.

The CAMERA connector is used to connect the camera to the AE1000Plus. The 4-conductor cable routes power to, and video from the camera.

The VIDEO jack is the camera output for connection to a video cable with a Type “BNC” connector. Up to 400 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.

Camera Installation

1.Remove the two plate locknuts from the camera mounting studs above the right keylock on the AE1000Plus faceplate.

2.Remove the cover plate.

3.Remove the protective backing from the plastic window included with the camera and install the plastic window onto the studs with the adhesive side against the door.

4.Remove the lens cap from the camera.

5.Mount the camera assembly on the two studs, with the alignment hole in the camera bracket towards the top. Secure the camera with the two locknuts.

6.Connect the camera’s cable to the AE1000Plus CAMERA connector.

7.Connect the video cable to the AE1000Plus VIDEO connector.

8.Connect the other end of the video cable to the viewing monitor or the video distribution system.

1 REMOVE PLATE RETAINING NUTS

2 REMOVE THE PLATE

COVER PLATE

3 INSTALL THE GASKET

4 REMOVE THE LENS CAP

GASKET

 

5 ATTACH CAMERA WITH TWO NUTS

6

CONNECT

 

 

CAMERA

HOLE

WIRING

ON TOP

HARNESS

 

7

 

CONNECT

 

VIDEO

 

CABLE

13

Image 13
Contents AE1000Plus Programming and Cardholder Maintenance ContentsIntroduction OperationFeature Overview Hardware FeaturesSoftware Highlights Wiegand Accessories Accessory Overview Pbus AccessoriesComponent Locations Installation NoteThis Wiring Example Shows Wiring DiagramImportant Mounting Requirements Mounting Preparation Entry System MountingSurface Mounting Surface MountingPedestal Mounting Recessed MountingDoor or Pedestrian Gate Control Relay Output WiringGate Control Request-to-Exit InputsPower Wiring Power, Battery, & Ground WiringBackup Battery / Uninterruptable Power Supply RS-232 PortImportant Telephone Wiring Tips Telephone WiringTypical Telephone Wiring Optional Radio AntennaCamera Installation Postal Lock InstallationOptional Postal Lock Wiegand Accessories Pbus AccessoriesRoute cable from the AE1000Plus to the accessory Wiegand TerminalsNetwork Configurations for Axnet Programming Optional Network ConnectionOptional Network Connections Network Configuration for AccessBase2000 ProgrammingNetwork Network Wiring with Hub RS-485 Network WiringNetwork Daisy-chain Wiring System Diagnostics System AdjustmentsDisplay shows the current network node number setting Refer to the following steps to change the system settingsInternal Controls On-board PushbuttonsRequesting Access with a Wireless Transmitter Requesting Access with an Entry CodeRequesting Access with a Visitor Call AE1000Plus OperationSpecifications Dimension Drawing16-1/4 18-3/8Troubleshooting FCC Notice Linear Limited WarrantyCopyright 2008 Linear LLC
Related manuals
Manual 12 pages 25.92 Kb

AE1000Plus specifications

The Linear AE1000Plus is a sophisticated access control and security system designed to meet the unique needs of residential and commercial environments. This advanced model is part of Linear’s commitment to providing reliable and efficient security solutions. It offers enhanced features, cutting-edge technologies, and exceptional characteristics that set it apart in the market.

One of the standout features of the AE1000Plus is its versatility in handling various access control modes. It supports access via key fobs, keypads, and biometric scanners, allowing for seamless integration with existing systems. This flexibility ensures that users can select the most appropriate method for their security requirements, enhancing convenience without compromising safety.

The AE1000Plus incorporates advanced wireless technology that facilitates easier installation and use. This wireless capability eliminates the need for extensive wiring, significantly reducing installation time and costs. Additionally, the system can communicate with Linear's extensive range of peripherals, including security cameras and alarm systems, providing a comprehensive security solution.

Another notable characteristic is its robust capacity for managing multiple users. The AE1000Plus can store a substantial number of user codes and fobs, making it ideal for larger facilities or properties with frequent visitor access. This feature empowers administrators with control over who can access specific areas while maintaining an audit trail of entries and exits.

The system is built with a user-friendly interface, ensuring ease of operation for both administrators and users. Programming and configuration can be streamlined through intuitive menus, while easily accessible manuals provide guidance for troubleshooting and adjustments. User experience is further enhanced by the AE1000Plus's compatibility with mobile applications, able to manage access remotely.

Security is paramount, and the AE1000Plus excels in implementing high-security standards. It employs encryption protocols that protect transmitted data from unauthorized access, ensuring the integrity and confidentiality of user information. The system is also designed to perform reliably in various environmental conditions, making it suitable for outdoor applications.

In summary, the Linear AE1000Plus combines versatility, advanced technology, and user-oriented design to create a leading access control solution. Its array of features ensures robust security while offering the flexibility to meet the demands of various settings, confirming Linear's position as a trusted name in the security industry. Whether for residential or commercial use, the AE1000Plus stands out as a reliable choice for modern security needs.