Linear AE1000Plus installation instructions Troubleshooting

Page 22

Troubleshooting

System completely dead

1.No power from transformer. Check voltage at transformer terminals.

2.Check voltage at AE1000Plus power terminal strip.

Buzz on speaker

1.Check for 24 volt AC power shorted to wiring conduit.

2.Check for telephone line shorted to ground.

3.Verify that telephone wires are twisted pair.

4.Verify that the AE1000Plus is connected to earth ground.

5.Check 16 VAC voltage at AE1000Plus transformer terminals.

Buzz on telephone line

1.Disconnect 16 VAC wires from terminal strip, if buzz goes away, one side of the transformer wires is grounded.

2.Check all connections for any shorts to ground.

System will not answer an incoming call

1.Automatic telephone answer disabled.

2.AE1000Plus telephone line trouble.

Entry code will not activate relay

1.Entry code not assigned.

2.Entry code not set up for proper relay.

3.Keypad is in lockout.

Remote PBUS device does not work

1.Check remote device address switch setting.

2.Check remote device for power.

3.Assure device is wired correctly.

Main or remote keypad will not activate a relay

1.Entry code is not assigned.

2.Keypad may be in lockout from too many incorrect attempts. Wait one minute for lockout to clear and try again.

3.Remote keypad wiring incorrect.

Resident’s Telephone does not ring when a visitor calls

1.Resident’s telephone number programmed incorrectly.

2.Check AE1000Plus telephone line.

3.Call resident from another line or cell phone to determine if the resident’s telephone is working.

Transmitter does not activate relay

1.Transmitter button setting programmed to “no relay” (would effect all transmitters).

2.Transmitter not enrolled.

3.Specifi c transmitter is deactivated in the system.

Poor transmitter radio range

1.Check antenna installation and condition if transmitters were previously working well.

2.Check the RADIO indicator on the AE1000Plus circuit board. If it is fl ickering without activating any transmitters there is interference blocking the receiver. Try adjusting the RECEIVER RANGE knob to reduce the receiver’s sensitivity to the interference.

3.Connect an audio amplifi er or telephone buttset to the RECEIVER TEST POINTS (the wire jumpers next to the RECEIVER RANGE knob). Listen to the sounds of the signals being received. If you hear the interference, remove power from possible interfering devices to determine the source of the interference. The antenna or the interfering device may need to be relocated.

4.Use Model FT-1 to check for interference.

22

Image 22
Contents AE1000Plus Introduction ContentsProgramming and Cardholder Maintenance OperationFeature Overview Hardware FeaturesSoftware Highlights Accessory Overview Pbus Accessories Wiegand AccessoriesInstallation Note Component LocationsWiring Diagram This Wiring Example ShowsImportant Mounting Requirements Surface Mounting Entry System MountingMounting Preparation Surface MountingRecessed Mounting Pedestal MountingGate Control Relay Output WiringDoor or Pedestrian Gate Control Request-to-Exit InputsBackup Battery / Uninterruptable Power Supply Power, Battery, & Ground WiringPower Wiring RS-232 PortTypical Telephone Wiring Telephone WiringImportant Telephone Wiring Tips Optional Radio AntennaCamera Installation Postal Lock InstallationOptional Postal Lock Route cable from the AE1000Plus to the accessory Pbus AccessoriesWiegand Accessories Wiegand TerminalsOptional Network Connection Network Configurations for Axnet ProgrammingOptional Network Connections Network Configuration for AccessBase2000 ProgrammingNetwork Network Wiring with Hub RS-485 Network WiringNetwork Daisy-chain Wiring System Adjustments System DiagnosticsInternal Controls Refer to the following steps to change the system settingsDisplay shows the current network node number setting On-board PushbuttonsRequesting Access with a Visitor Call Requesting Access with an Entry CodeRequesting Access with a Wireless Transmitter AE1000Plus Operation16-1/4 Dimension DrawingSpecifications 18-3/8Troubleshooting Linear Limited Warranty FCC NoticeCopyright 2008 Linear LLC
Related manuals
Manual 12 pages 25.92 Kb

AE1000Plus specifications

The Linear AE1000Plus is a sophisticated access control and security system designed to meet the unique needs of residential and commercial environments. This advanced model is part of Linear’s commitment to providing reliable and efficient security solutions. It offers enhanced features, cutting-edge technologies, and exceptional characteristics that set it apart in the market.

One of the standout features of the AE1000Plus is its versatility in handling various access control modes. It supports access via key fobs, keypads, and biometric scanners, allowing for seamless integration with existing systems. This flexibility ensures that users can select the most appropriate method for their security requirements, enhancing convenience without compromising safety.

The AE1000Plus incorporates advanced wireless technology that facilitates easier installation and use. This wireless capability eliminates the need for extensive wiring, significantly reducing installation time and costs. Additionally, the system can communicate with Linear's extensive range of peripherals, including security cameras and alarm systems, providing a comprehensive security solution.

Another notable characteristic is its robust capacity for managing multiple users. The AE1000Plus can store a substantial number of user codes and fobs, making it ideal for larger facilities or properties with frequent visitor access. This feature empowers administrators with control over who can access specific areas while maintaining an audit trail of entries and exits.

The system is built with a user-friendly interface, ensuring ease of operation for both administrators and users. Programming and configuration can be streamlined through intuitive menus, while easily accessible manuals provide guidance for troubleshooting and adjustments. User experience is further enhanced by the AE1000Plus's compatibility with mobile applications, able to manage access remotely.

Security is paramount, and the AE1000Plus excels in implementing high-security standards. It employs encryption protocols that protect transmitted data from unauthorized access, ensuring the integrity and confidentiality of user information. The system is also designed to perform reliably in various environmental conditions, making it suitable for outdoor applications.

In summary, the Linear AE1000Plus combines versatility, advanced technology, and user-oriented design to create a leading access control solution. Its array of features ensures robust security while offering the flexibility to meet the demands of various settings, confirming Linear's position as a trusted name in the security industry. Whether for residential or commercial use, the AE1000Plus stands out as a reliable choice for modern security needs.