Magellan MG-6060 installation manual User Codes

Page 14

User Codes

A person must be assigned to a user code in order to have access to Magellan. A user code defines the extent of a user’s access to the system and consists of a code # (PIN) and user options. Magellan supports one Installer code, one Maintenance code and up to 16 user codes (one System Master code and 15 User codes).

Installer Code

Used to program all console settings

 

except User codes and Remote Controls

 

 

Maintenance Code

Identical to the Installer code except that

 

the code cannot program dialer options or

 

perform a software reset.

 

 

System Master Code

Provides access to the following Magellan

User Code 001

user features: language, voice and utility

 

reporting, delays and tones, zone labels,

 

system tests. Arm and disarm using any

 

method as well as program User Codes.

 

 

15 User Codes

Can arm and disarm the system.

User Codes 002 to 016

 

 

 

Maintenance Code

Section [182]; Default = 111111

The Maintenance code is similar to the Installer code. It can be used to enter the console’s programming mode (see Programming Using the Built-in Keypad on page 11), which allows you to program all features, options and commands except for the console’s communication settings (sections [100] to [154]) as well as any user code. The Maintenance code can be 4 or 6 digits in length (see User Code Length on page 12) where each digit can be any value from 0 to 9.

To change the Maintenance code:

1.Access the installer programming mode (page 11).

2.Enter section [182].

3.Enter a new [4- OR 6-DIGIT MAINTENANCE CODE].

OR

1.Press [MENU] + [4] + [INSTALLER CODE] + [8] + [NEW CODE].

User Code Length

Section [090]: Option [1]

Option [1] OFF = 6-digit user codes

Option [1] ON = 4-digit user codes (default)

All user codes can be set to lengths of either 4 or 6 digits. When the 4-digit option is selected, entering a 4-digit code will allow access. Using the 6-digit option, entering 6 digits is required to allow access.

If the User Code Length is changed from 4 digits to 6 digits when user codes have already been programmed, the console will automatically add the last 2 digits by using the first 2 digits. For example, if the access code is 1234 and you switch to 6 digits, the code will become 123412. Be sure to verify the access codes after switching from 4-digit to 6-digit access codes. When switching from 6 digits to 4 digits, the console will simply remove the final 2 digits of the access code. For example, 123456 will become 1234.

System Master Code

With the System Master code a user can use any arming method and can program any user’s (from 1 to 16) Access Code. The System Master code can be 4 or 6 digits in length (see User Code Length on page 12), where each digit can be any digit from 0 to 9. The System Master code cannot be changed by the installer or maintenance code, but it can be reset to default.

Lock System Master Code

Section [090]: Option [3]

Option [3] OFF =System Master code unlocked (default) Option [3] ON =System Master code locked

With section [090] option [3] enabled, the System Master code can only be changed or deleted through WinLoad or a power down reset.

Installer Code

Section [181]; Default = 000000

The Installer code is used to enter the console's programming mode (see Programming Using the Built-in Keypad on page 11), which allows you to program all the features, options and commands of the Magellan console. The Installer code can be 4- or 6-digits in length (see User Code Length on page 12) where each digit can be any value from 0 to 9. The Installer code cannot be used to program any user code.

To change the Installer code:

1.Access the installer programming mode (page 11).

2.Enter section [181].

3.Enter a new [4- OR 6-DIGIT INSTALLER CODE].

OR

1.Press [MENU] + [4] + [INSTALLER CODE] + [8] + [NEW CODE].

Reset System Master Code

Section [200]

Enter section [200] to reset the System Master code to default (1234/123456).

Make sure that the Lock System Master Code feature (section [090] option [3]) is disabled.

Duress Code

Section [090]: Option [4]

Option [4] OFF = Duress code disabled (default)

Option [4] ON = User code 016 becomes a duress code

With this feature enabled, user code 016 becomes a Duress code. When forced to arm or disarm their system, users can enter a Duress code (user code 016) to arm or disarm the system which can immediately transmit a silent alert to the Central Station, transmitting the duress report code programmed in section [140] (page 25).

12

Reference & Installation Manual

Image 14
Contents Page Page Table of Contents List Index About Magellan and this Manual SpecificationsIntroduction ConventionsQuick Setup Time and Date PasswordsInstaller code Maintenance code Panel ID PC Password Deleting ZonesBackup Battery Pack InstallationAC Power Telephone Line ConnectionsProgrammable Outputs PGMs Line Plug ConnectUIP-256 Universal In-Field Programmer Connection Hardwire Zone ConnectionsWinLoad Connection Location and Mounting Connecting a Paradox Memory Key PMC-3X10 Transmitter Connection LocationTabletop Mounting Connecting the Radio AntennaMounting Magellan on the Wall Programming Using a Paradox Memory Key WinLoad Installer Upload/Download SoftwareProgramming Using the Built-in Keypad Programming MethodsUser Codes Zone Definitions Entry DelayZone Programming Zone Programming OverviewInstant Zones Delayed Fire ZonesFollow/Stay Zones Instant/Stay ZonesZone Options Zones 15 and 16 become Hardwire Zones EOL End-Of-Line ZonesDeleting Assigned Wireless Transmitters Wireless ProgrammingAssigning Wireless Zone Transmitters Assigning Wireless Doorbells to the ConsoleRemote Control Button Programming Assigning Remote ControlsProgramming the Remote Control’s Buttons Section Data refer to on UserStep Battery type One 3V lithium battery CR2032How to replace the battery Hexa DescriptionArming and Disarming No Exit Delay when Arming with Remote Control Exit DelayBell Squawk on Arm/Disarm with Remote Control Exit Delay TerminationWireless Transmitter Supervision Options Alarm OptionsBell Cut-off Timer Tamper Recognition OptionsPanic Alarm Keys Panic AlarmsPanic Alarm Types Check-in Supervision TimeReporting and Dialer Settings Report CodesConsole Telephone Numbers Central Station Telephone Numbers CSTNs Service Telephone NumberConsole Account Number Pager Telephone NumberStandard Pulse Formats Reporting FormatsEvent Call Direction Ademco Contact IDRecent Close Delay Delay Between Dialing AttemptsSwitch to Pulse Dialing on 5th Attempt Alternate Dial OptionAuto-Test Report Power Failure Report DelayZone Restore Report Options Disarm Reporting OptionsProgrammable Outputs System Settings Trouble Description WinLoad Software Settings Appendix 1 Ademco Contact ID Report Code List Sounder Relay Disabled Remote AccessAccess Control 420 Communication Troubles 350Bypasses Communication Disables 550Modules Test/MiscNumerics Bell Cut-off timerIndex 24Hr. Burglary ZonesAuto-arm options Closing Delinquency Timer Exit delay Exit Delay TerminationAnswering machine override No Movement Auto-arming One-touch armingDelay before Alarm Report Code Transmission Overview, zone programmingTest report code Test Report, Automatic Timed Auto-arming Shutdown, Auto-zoneTelephone numbers Zone, hardwire Programming remote control buttonsDelay before Alarm Code Transmission Reference & Installation Manual Warranty Page Page MAGELLAN-EI01

MG-6060 specifications

The Magellan MG-6060 is a sophisticated GPS tracking device designed to enhance navigation and tracking capabilities for both individual users and businesses. With its advanced features and robust technology, the MG-6060 stands out in the market, catering to a diverse range of applications, including fleet management, personal tracking, and outdoor adventures.

One of the key highlights of the MG-6060 is its superior GPS accuracy. Utilizing a high-sensitivity GPS receiver, this device can provide precise location information, ensuring that users can track their assets in real time. Whether you’re managing a fleet of vehicles or keeping an eye on a loved one, the MG-6060 offers reliable tracking capabilities.

The device is equipped with cellular network communication, enabling seamless data transmission. This means that users can access their tracking information via a dedicated app or web platform, allowing for easy monitoring and management. The user-friendly interface of the accompanying software makes it simple to visualize tracking data, set up geofencing alerts, and receive real-time notifications.

Battery life is another important characteristic of the MG-6060. It features a long-lasting rechargeable battery that can provide extended usage times, making it suitable for various tracking applications. Users can enjoy the convenience of extended periods without needing a recharge, which is especially valuable in outdoor environments.

Durability is also a standout feature of the MG-6060. It is designed to withstand harsh conditions, making it perfect for rugged outdoor use. With an IP67 rating for water and dust resistance, the device can operate effectively in tough environments, ensuring that it remains functional regardless of the circumstances.

Moreover, the MG-6060 supports both GPS and GLONASS systems, offering enhanced satellite connectivity. This dual-constellation capability significantly improves positioning accuracy and reliability, especially in urban settings where tall buildings can obstruct satellite signals.

In summary, the Magellan MG-6060 stands out with its precise GPS tracking capabilities, user-friendly software, long battery life, and durable design. Its advanced features make it suitable for a variety of applications, positioning it as a versatile tool for effective tracking and navigation. Whether for personal use or business needs, the MG-6060 provides functionality that users can rely on in all situations.