Magellan MG-6060 Panic Alarms, Check-in Supervision Time, Panic Alarm Types, Panic Alarm Keys

Page 25

presence and functionality. If a device has not sent a signal within the specified time period, Magellan can generate a trouble, an alarm and/or transmit a report code to the central monitoring station as defined by the Wireless Transmitter Supervision Options (page 22). Sections [103] and [104] determine which zones will be supervised and which will not. Enable the option pertaining to the zone you wish Magellan to supervise.

Check-in Supervision Time

Section [096]: Option [7]

Option [7] OFF =Check-in supervision time = 24Hrs (default) Option [7] ON =Check-in supervision time = 80 minutes

Section [096] option [7] defines the time period that Magellan will expect a check-in status signal from the specified wireless transmitters as defined in the Check-in Supervision Options (page 22). If no signal is received within the check-in supervision time, Magellan’s reaction will be defined by the Wireless Transmitter Supervision Options (page 22).

Panic Alarms

Section [091]: Options [1], [2] and [3]

Option [1] OFF = Panic 1 (Emergency Panic) disabled (default) Option [1] ON = Panic 1 (Emergency Panic) enabled

Option [2] OFF = Panic 2 (Auxiliary Panic) disabled (default) Option [2] ON = Panic 2 (Auxiliary Panic) enabled

Option [3] OFF = Panic 3 (Fire Panic) disabled (default) Option [3] ON = Panic 3 (Fire Panic) enabled

Enable section [091] options [1], [2] and [3] to enable the system’s three Panic alarms. Each panic alarm is activated by pressing two keys simultaneously and holding them down for 2 seconds. See Table 7 on page 23 for the appropriate panic alarm keys. Whether these panic alarms will generate a silent or audible alarm is determined by section [091] options [4] to [6] (see Panic Alarm Types on page 23).

Table 7: Panic Alarm Keys

Keys to press

Panic Alarm Type

 

 

 

[1] and [3]

Panic 1

(Emergency Panic)

 

 

 

[4] and [6]

Panic 2

(Auxiliary Panic)

 

 

 

[7] and [9]

Panic 3

(Fire Panic)

 

 

 

Remote controls can also be programmed to generate panic alarms. See Programming the Remote Control’s Buttons on page 18 for more information on programming remote controls to generate panic alarms.

Panic Alarm Types

Section [091]: Options [4], [5] and [6]

Option [4] OFF =Panic 1 (Emergency Panic) is silent (default) Option [4] ON =Panic 1 (Emergency Panic) is audible

Option [5] OFF =Panic 2 (Auxiliary Panic) is silent (default) Option [5] ON =Panic 2 (Auxiliary Panic) is audible

Option [6] OFF =Panic 3 (Fire Panic) is silent (default) Option [6] ON =Panic 3 (Fire Panic) is pulsed

Options [4] to [6] represent the alarm types of panic alarms 1 to 3 respectively.

Silent Alarm: The Magellan console will emit a confirmation beep and transmit the appropriate Panic report code (if programmed in section [139]). The console will not enable its speaker or the system siren.

Audible Alarm: Same as the silent alarm except that the console will enable its speaker and system siren until a user cancels the alarm (disarms) with a valid access code or when the Bell Cut-off timer elapses (if enabled; see Bell Cut-off Timer on page 22).

Pulsed Alarm (Fire Panic only): Same as the audible alarm except that the siren will be pulsed as shown in Figure 17 on page 14. Refer to Standard 24Hr. Fire Zones on page 14 for more information on a pulsed siren output.

Paradox Magellan Systems

23

Image 25
Contents Page Page Table of Contents List Index Introduction SpecificationsAbout Magellan and this Manual ConventionsQuick Setup Installer code Maintenance code Panel ID PC Password PasswordsTime and Date Deleting ZonesAC Power InstallationBackup Battery Pack Telephone Line ConnectionsLine Plug Connect Programmable Outputs PGMsWinLoad Connection Hardwire Zone ConnectionsUIP-256 Universal In-Field Programmer Connection X10 Transmitter Connection Connecting a Paradox Memory Key PMC-3Location and Mounting LocationMounting Magellan on the Wall Connecting the Radio AntennaTabletop Mounting Programming Using the Built-in Keypad WinLoad Installer Upload/Download SoftwareProgramming Using a Paradox Memory Key Programming MethodsUser Codes Zone Programming Entry DelayZone Definitions Zone Programming OverviewFollow/Stay Zones Delayed Fire ZonesInstant Zones Instant/Stay ZonesZone Options EOL End-Of-Line Zones Zones 15 and 16 become Hardwire ZonesAssigning Wireless Zone Transmitters Wireless ProgrammingDeleting Assigned Wireless Transmitters Assigning Wireless Doorbells to the ConsoleProgramming the Remote Control’s Buttons Assigning Remote ControlsRemote Control Button Programming Section Data refer to on UserHow to replace the battery Battery type One 3V lithium battery CR2032Step Hexa DescriptionArming and Disarming Bell Squawk on Arm/Disarm with Remote Control Exit DelayNo Exit Delay when Arming with Remote Control Exit Delay TerminationBell Cut-off Timer Alarm OptionsWireless Transmitter Supervision Options Tamper Recognition OptionsPanic Alarm Types Panic AlarmsPanic Alarm Keys Check-in Supervision TimeReport Codes Reporting and Dialer SettingsConsole Telephone Numbers Console Account Number Service Telephone NumberCentral Station Telephone Numbers CSTNs Pager Telephone NumberEvent Call Direction Reporting FormatsStandard Pulse Formats Ademco Contact IDSwitch to Pulse Dialing on 5th Attempt Delay Between Dialing AttemptsRecent Close Delay Alternate Dial OptionZone Restore Report Options Power Failure Report DelayAuto-Test Report Disarm Reporting OptionsProgrammable Outputs System Settings Trouble Description WinLoad Software Settings Appendix 1 Ademco Contact ID Report Code List Access Control 420 Remote AccessSounder Relay Disabled Communication Troubles 350Modules Communication Disables 550Bypasses Test/MiscIndex Bell Cut-off timerNumerics 24Hr. Burglary ZonesAnswering machine override Closing Delinquency Timer Exit delay Exit Delay TerminationAuto-arm options No Movement Auto-arming One-touch armingOverview, zone programming Delay before Alarm Report Code TransmissionTelephone numbers Shutdown, Auto-zoneTest report code Test Report, Automatic Timed Auto-arming Delay before Alarm Code Transmission Programming remote control buttonsZone, hardwire Reference & Installation Manual Warranty Page Page MAGELLAN-EI01

MG-6060 specifications

The Magellan MG-6060 is a sophisticated GPS tracking device designed to enhance navigation and tracking capabilities for both individual users and businesses. With its advanced features and robust technology, the MG-6060 stands out in the market, catering to a diverse range of applications, including fleet management, personal tracking, and outdoor adventures.

One of the key highlights of the MG-6060 is its superior GPS accuracy. Utilizing a high-sensitivity GPS receiver, this device can provide precise location information, ensuring that users can track their assets in real time. Whether you’re managing a fleet of vehicles or keeping an eye on a loved one, the MG-6060 offers reliable tracking capabilities.

The device is equipped with cellular network communication, enabling seamless data transmission. This means that users can access their tracking information via a dedicated app or web platform, allowing for easy monitoring and management. The user-friendly interface of the accompanying software makes it simple to visualize tracking data, set up geofencing alerts, and receive real-time notifications.

Battery life is another important characteristic of the MG-6060. It features a long-lasting rechargeable battery that can provide extended usage times, making it suitable for various tracking applications. Users can enjoy the convenience of extended periods without needing a recharge, which is especially valuable in outdoor environments.

Durability is also a standout feature of the MG-6060. It is designed to withstand harsh conditions, making it perfect for rugged outdoor use. With an IP67 rating for water and dust resistance, the device can operate effectively in tough environments, ensuring that it remains functional regardless of the circumstances.

Moreover, the MG-6060 supports both GPS and GLONASS systems, offering enhanced satellite connectivity. This dual-constellation capability significantly improves positioning accuracy and reliability, especially in urban settings where tall buildings can obstruct satellite signals.

In summary, the Magellan MG-6060 stands out with its precise GPS tracking capabilities, user-friendly software, long battery life, and durable design. Its advanced features make it suitable for a variety of applications, positioning it as a versatile tool for effective tracking and navigation. Whether for personal use or business needs, the MG-6060 provides functionality that users can rely on in all situations.