Terminal Adapters

DVST Installation Guide

8.4ASCOM 5000 / CITAM

ATMODE

Cables required - 2x 15 to 15 (Part No. AS-DVST-X21). Dip switch settings can be used and should be set as follows:

Note: Switch 3 selects the sub address, if used.

Fig 5: ASCOM internal dip switch settings (ATMODE)

Step Instruction

1Using the pull handle, remove the circuit board module from the Citam 5000

2Adjust the dip switches as shown in Figure 9

3Press the select key four times so that the legend ‘CONF’ appears on the display.

4Press the enter key once and it will say ‘PRT1’, press the select key twice it will say ‘TA’ , press the enter key it will say ‘SHOW’.

5Press and hold select until the display reads ‘CHNG’, remove your finger from the select key and press the enter key, ‘ I N D B ’ will be displayed.

6Press the enter key, the message will be ‘ON’, use the select key to turn this to ‘OFF’, then press the enter key.

7Hold the select key and press the enter key, the display will return to ‘CONF’.

8At ‘CONF’ press the enter key, the display will read ‘PRT1’ for port 1.

Remarks

The Citam will now perform a self test. On completion the display will read ISDN.

This has turned of the in-band test feature of the unit.

Page 34

Dedicated Micros Ltd

Image 46
Contents Page Page Installation Guide DFT-0150Page Safety Page A. and Canadian Models Only Regulatory NotesFCC and DOC Information CE MarkPage Table of Contents Demonstration Mode ModemsCalls Terminal AdaptersLeased Line Transmission Images and TransmissionAudio Alarms & EventsGlossary Returns Procedure Cable AssembliesDFT-0150 Transmitter Event monitoring Alarms1Introduction TelemetryPage Items in packing Unpacking the unitPacking the Dvst Page 3Operation Alarms FeatureCallback Track Last Alarm Freeze All AlarmsOffline Frozen Alarm No Frozen Images4Installation Rear Panel connectionsPower Inputs 37 Way Alarm ConnectionsSetup using a PC 5SetupWhat you require Remote Setup Dvst CommandsDefine Camera Inputs Auxiliary PortSet Port usage Each field entry is separated by a space. If Default settings AUX1 N 38400Define Auxiliary Ports 1,2 AUX2 N 38400Demonstration Mode Demonstration modeDemo Cable Tech NoteConnecting the demo cable Single cable operationPage 7Modems Modem CommandsPstn Connection Modem MBAUD= Set Modem port Async baud rate. default 9600, 19200 ModemModem configuration strings MODSTR= Set type of modem Fast or Sync default, FastUSER=... Available for user configuration Default, blank Zyxel US Modems OnlyModem Operation Default, AtdtModem dial string Call request Connecting a modem in direct modeConfiguration of modem in direct mode Call answer requestUsing a modem in Atmode General settings for modems in AtmodeAll modems Action required of Modem Possible AT settingsModem Requirements Synchronous ModemsCountry specific settings MINIT=AT&M1 &D2 &C1 *FLO *OC1 *DTO *DE12 *AA1User=ATX3*BDO&Y1&W1 Where No DialtoneTransmission speed AT*MXnDIP Switch Settings Synchronous Operation Syncronous modeMicrocom Async mode TrailblazerSend RET Octocom OSI 8196AModem RET Modems Dvst Installation Guide This page intentionally blank Isdn Connection Terminal Adapter Default, onTerminal Adapters Sets dual Isdn support on or OFFMaking a Call Connecting a terminal adapter in direct modeConfiguring a Terminal Adapter for direct mode operation Answering a CallGandalf TA1 Direct ConnectionStep Instruction Ascom 5000 / CitamRemarks ISDN=ATMODE RET DUALISDN=ON RET Isdnstr = Citam RET ISDN0 RET Atret AT&WRET, ESC ISDN1RET AtretStep Instruction Remarks X21AT&WRET ESC Quit RET ‘CONF’‘DIPS’ ‘CHNG’ISDN=ATMODE RET Dataflex TAQuit RET Leased Line Transmission Dvst set up for leased line operationLEASED= Leased line operation, options are default, OFF Leased line terminologyLeased line operation SET UP RX or Slave END SET UP TX or Master ENDAscom 64000 Baseband Modem Page Set telephone entry n password to PasswordsPASSWORD= Set system password to 10CallsOn Screen Titling Set telephone entry n to Telephone Number Entries / Connection CommandsDefault, blank FormatDefault, 30 seconds Call connection timeout periodDefault, 60 seconds CALLBACK= Set call back on or OFF Default, offImage size CAMLO=Sets low resolution cameo operationImages and Transmission Target Picture SizesPage Alarm Settings Alarms & EventsAlarm Connections Purpose & intended useSet contact nn normally open Images transmitted on alarmSet contact nn normally closed Default is Auto Set alarm outputs Auto / ManualALMODE= ...Set Alarm operation mode Alarms & Events Dvst Installation Guide 13Audio Equipment required but not suppliedConnecting the DAL100 Cable Assemblies 14.1 X21 to V35 Cable Assembly 14.2 X21 Cable Assembly 14.3 V24 Sync Modem Cable Assembly 14.4 RS232 Cable Assembly DVST-PC 14.5 RS232 Cable Assembly DVST-DAL 15Glossary IsdnPage Returns Procedure Event of DifficultyPage Dvst Installation Guide Returns Procedure Returns Procedure Dvst Installation Guide

DVST, DFT 150/175 specifications

Guardian Technologies has made significant strides in the air purification industry with its innovative DFT 150 and DFT 175 models, designed to enhance indoor air quality for both residential and commercial spaces. These advanced devices leverage cutting-edge technology to deliver clean, fresh air, addressing the increasing need for effective air purification solutions.

One of the standout features of the DFT series is its multi-stage filtration system. Both the DFT 150 and DFT 175 are equipped with a pre-filter that captures large particles, such as dust and hair, followed by a true HEPA filter. This HEPA filter is capable of capturing 99.97% of airborne pollutants as small as 0.3 microns, including allergens, mold spores, and pet dander. This is an essential feature for individuals suffering from allergies or respiratory issues, ensuring that the air they breathe is significantly cleaner.

In addition to the HEPA filtration, Guardian Technologies has incorporated a UV-C light that works in tandem with the filter system. This technology helps to kill airborne bacteria and viruses, providing an extra layer of protection against pathogens, which is particularly crucial in today’s health-conscious environment.

Another characteristic that sets the DFT 150 and 175 apart is their energy efficiency. Both models are designed to operate quietly and consume minimal energy, making them suitable for continuous use in bedrooms, living rooms, or offices without causing a spike in electricity bills. The DFT 175 model features an added air quality sensor, which monitors and adjusts the fan speed automatically based on the detected air quality, ensuring optimal performance without unnecessary energy expenditure.

The sleek, modern design of the DFT series ensures they blend seamlessly into any decor. With portable options, users can easily move these units from one room to another, providing flexibility in air purification.

Moreover, the DFT models come equipped with easy-to-replace filter indicators, notifying users when it’s time to replace the filters. This convenience promotes consistent air quality management without the hassle of manual reminders.

In conclusion, Guardian Technologies' DFT 150 and DFT 175 models represent an excellent investment for anyone looking to improve indoor air quality. Their sophisticated filtration technology, additional UV-C features, energy efficiency, and user-friendly design make them a top choice for air purifiers in the market today.