Note: The low battery message comes on as a warning that battery replacement in indicated sensor(s) is due within 30 days. In the meantime, the sensor(s) causing the low battery indication is still fully operational.

Important: Use only batteries recommended by your installer as replacement.

Silencing Low Battery Warning Tones at the Keypad

The keypad’s warning tones can be silenced by performing an OFF sequence (code plus OFF key), but the Keypad's low battery message display will remain on as a reminder that you have a low battery condition in one or more of your sensors. When you replace the weak battery with a fresh one, the sensor will send a "good battery" signal to the control as soon as the sensor is activated (opening/closing of door, window, etc.), causing the low battery display to turn off. If the sensor is not activated, the display will automatically clear within approximately 1 hour.

Routine Care

Treat the components of your security system as you would any other electrical equipment. Do not slam sensor-protected doors or windows.

Keep dust from accumulating on the keypad and all protective sensors, particularly on motion sensors and smoke detectors.

The keypad and sensors should be cleaned carefully with a dry soft cloth. Do not spray water or any other fluid on the units.

– 68 –

Technical Manuals Online! - http://www.tech-man.com

Image 68
Contents $&&$&% Table of Contents Trouble Conditions Partitioned System System OverviewGeneral System Overview cont’d ZonesFire Protection Burglary ProtectionSpeed Key Macros AlarmsMemory of Alarm To Access Another Partition Goto Command Using SchedulesDevice Timers Self-Help Feature Phone Access & Voice Response CapabilityMaster Keypad Operation To view the abbreviated instructionsSystem Overview cont’d About The Keypads Alpha KeypadFunctions Of The Keypad Functions Of The Keypad cont’d Functions Of The Keypad cont’d Entry/Exit Delays General InformationQuick Arming Security Codes & Authority LevelsDuress Code Security Codes & Authority Levels cont’d Authority LevelsGeneral Rules on Authority Levels and Changes To view your authority level and system capabilitiesTo Exit User Edit Mode To Add a UserRF Button ? Limited Use User#84 Command To Change a Users CodeTo Delete a User Accessing Other Partitions To Access Another PartitionGlobal Arming To Goto another partitionAccessing Other Partitions cont’d Fault 002 Loading Dock Window Common Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/Disarming Using Ready Key To show faulted zonesTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones To use the Quick Bypass feature Bypassing Protection Zones cont’dQuick Bypass Displaying Bypassed ZonesUsing the 3 Stay key Arming Perimeter OnlyWith Entry Delay OFF Using the 7 Instant KeyUsing the 2 Away Key Arming All ProtectionUsing the 4 Maximum Key To disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarming Using The KeyswitchArming Chime Mode Using KeyViewing Central Station Messages Using Panic Keys Panic KeysSpeed Key Macros DefiningSpeed Key Macros cont’d ExecutingAccess Door Control Using #70 Relay Menu Mode To activate relays using a telephone and 4285 or 4286 VIPUsing #70 Relay Menu Mode cont’d To Exit Enter 00 NOWUsing Schedules Delaying the Closing TimeTo delay the closing time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules Using Schedules cont’d Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modeProgramming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ? Select the partition Event Log ProceduresTo Display The Event Log Event Logging Procedures To Exit the Event LogTesting The System Using the 5 Test KeyTesting The System cont’d Testing Your SystemSilencing a Fire Alarm Fire Alarm SystemCase Of Fire Alarm Fire Drill Test Code + # + Fire Alarm System cont’dFire Display Lock Fire Alarm System cont’d Trouble Conditions Typical Trouble DisplaysCall for Service Immediately Trouble Conditions cont’dPower Failure Servicing InformationRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Protection cont’d Addition, we recommend the followingRecommendations For Proper Intrusion Protection Emergency Evacuation Taking Care of Your System Replacing Batteries in Wireless SensorsMaintaining Your System Routine Care Silencing Low Battery Warning Tones at the KeypadMaintaining Your System cont’d Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsGlossary Federal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System Index AwayLsens ¬19¢Ll