Kenmore 305, 505 owner manual Error Codes Code Fault, Remedy

Page 27

This appliance has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you to overcome a problem without a service call. Please identify the code displayed when inquiring about service.

Some of the checks below may need to be done by a qualified service technician. Call a service technician for any remedy that involves gas or electricity. Call a service technician if you have any doubt or reservation about

perform ng the remedy yourse f.

Table 10: Error Codes

Code Fault

02No burner operation during freeze protection mode

10Air Supply or Exhaust Blockage

11No Ignition

12Flame Failure

Remedy

ServiceCall - Check for possiblefreezedamage to heatexchanger.

Ensure approved venting materials are being used.

Check that nothing is blocking the flue inlet or exhaust.

Check all vent components for proper connections.

Ensure vent length is within limits.

Ensure condensation collar was installed correctly.

Verify dip switches are set properly.

Check fan for blockage.

Check that the gas is turned on at the water heater, gas meter, or cylinder. Ensure gas type and pressure is correct.

Ensure gas line, meter, and/or regulator is sized properly. Bleed all air from gas lines.

Verify dip switches are set properly.

Ensure appliance is properly grounded.

Disconnect all 2-Unit or Multi-Unit connections to isolate the problem. Ensure igniter is operational.

Check igniter wiring harness for damage.

Check gas solenoid valves for open or short circuits.

Remove burner cover and ensure all burners are properly seated.

Remove burner plate and inspect burner surface for condensation or debris.

Check that the gas is turned on at the water heater and gas meter. Check for obstructions in the flue outlet.

Ensure gas line, meter, and/or regulator is sized properly. Ensure gas type and pressure is correct.

Bleed all air from gas lines.

Ensure proper venting material was installed.

Ensure condensation collar was installed properly.

Ensure vent length is within limits.

Verify dip switches are set properly.

Ensure appliance is properly grounded.

Disconnect keypad.

Disconnect all 2-Unit or Multi-Unit connections to isolate the problem. Check power supply for loose connections.

Check power supply for proper voltage and voltage drops. Ensure flame rod wire is connected.

Check flame rod for carbon build-up.

Disconnect and reconnect all wiring harnesses on unit and PC board. Check all components for electrical short.

Check gas solenoid valves for open or short circuits.

Remove burner plate and inspect burner surface for condensation or debris.

305 & 505 Outdoor Manual

27

Image 27
Contents Direct Vent Tankless Water Heaters 505 ModelsImportant Definitions Read and follow water heater warnings and instructionsSafety Features Safety Behavior and PracticesPressure Relief Valve Freeze Safe Installation UseSafety Precautions Dimensions TechnicalMaster Protection Agreements ImportantInformationAbout This Water Heater Excessive Weight HazardModels 505 Model++D Outlet Flow Data Pressure Drop CurveTos General InstructionsElectrical Connection 120vAccoe,o22,RES..EcTPipe Sizing Table Propane Gas Pipe Sizing Procedure ExamplePipe Sizing Table Natural Gas Length Pipe Size InchesGeneral Instructions Pressure Relief ValveFreezing Protection Water Heater Freeze Protection Piping DrawingRecommended Piping for Basic Installation Recommended Piping for Circulation Systems Water HeaterMinimum 3/4 ColdWater Supply Une For the circulation systemClosed Corner Guidelines Location Cable Length and SizeMounting the Controller Features Available on Temperature Controllers Features DescriptionSequence of Operation 160F 71C 150F 66C 140F 60C 130F 54C 120F 49C 80F 27C Re-setting the Maximum Temperature Temperature Options without a Temperature ControllerTemperature Ranges Model Temperature Settings AvailableFor Your Safety Read Before Operating Lime / Scale Build-up Temperature ControllerVent System MotorsRemedy Error Codes Code FaultLC or Thermal FuseMaximum Level When I open a hot tap, I do not immediately get hot waterAccessing Operating Information Water QualityH1 Circulating Pump Flushing the Heat Exchanger ErrorCode LC orSW,TC......i,seF Repair Parts List 305&505OutdoorManual33 34305&505OutdoorManual 305&505OutdoorManual35 Iiiiiiiii