Kenmore 153.339462, 153.33968, 153.339562, 153.33964, 153.339762, 153.339962 Leakage Checkpoints

Page 25

Operational Conditions (Continued)

Leakage Checkpoints

FIGURE 28.

Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.

Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater, see Figure 28.

A.Water at the draft hood is water vapor which has condensed out of the combustion products. This is caused by a problem in the vent. Contact the gas utility.

B.*Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C.*The anode rod fitting may be leaking.

D.Small amounts of water from temperature-pressure relief valve may be due to thermal expansion or high water pressure in your area.

E.*The temperature-pressure relief valve may be leaking at the tank fitting.

F.Water from a drain valve may be due to the valve being slightly opened.

G.*The drain valve may be leaking at the tank fitting.

H.Combustion products contain water vapor which can condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

I.Water in the water heater bottom or on the floor may be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

*To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow

“Draining” instructions in the Periodic Maintenance section and then remove fitting. Put pipe dope or Teflon tape on the threads and replace. Then follow Filling the Water Heater instructions in the Installing the New Water Heater section.

25

Image 25
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser 9 GAS Water HeaterImportant Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsGET to Know Your Water Heater GAS Models Typical InstallationRemoving the Old Water Heater Installation InstructionsFacts to Consider About the Location Insulation Blankets ALL AIR from Inside Buildings Hotter Water can Scald Water PipingValve and Pipe Insulation Temperature-Pressure Relief Valve Venting Filling the Water HeaterGas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions For Your Safety Read Before LightingTemperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and AdjustmentBurner Cleaning Vent System Inspection Burner InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Service Drain Valve Washer ReplacementDraining Start Up Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Troubleshooting Guide Parts Order List 153.339962 Gallon L.P 153.339161 Gallon Short Part Description 153.339562 153.339762 153.339640 153.339680 Page Page MY-HOME