Kenmore 153.332111, 153.332419, 153.332463 Temperature-Pressure Relief Valve, Relief Valve Opening

Page 12

Installation Instructions (cont'd)

Temperature-Pressure Relief Valve

_,WARNING

At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve certified

by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or mate- rials, as meeting the requirements for Relief Valves and

Automatic Gas Shutoff Devicesfor Hot Water Supply Systems, and the latest edition of ANSI Z21.22 and the code require- ments of ASME. If replaced, the valve must meet the require- ments of local codes,but not less than a combination tempera- ture and pressure relief valve certified as meeting the require- ments for Relief Valves and Automatic Gas Shutoff Devicesfor Hot Water Supply Systems, ANSI Z21.22 by a nationally recog- nized testing laboratory that maintains periodic inspection of production of listed equipment or materials.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 Ibs./sq.in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3415 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use of a temperature-pressure relief valve complying with ANSI Z2h22 and ASME, may require a valve model different from the one furnished with the water heater

Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally pre- scribed temperature-pressure relief valve installed in the desig-

nated opening in the water heater in place of the factory fur- nished valve.

For safe operation of the water heater, the relief valve must not be removed from it'sdesignated opening or plugged.

The temperature.pressure relief valve must be installeddirectly into the fitting of the water heater designatedfor the relief valve. Position the valve downward and provide tubing so that any dis- i

charge will exit only within 6 inches above, or at any distance below the structural floor Be certain that no contact is made

with any live electrical part. The dischargeopening must not be _locked or reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and reduce the dischargecapacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unlessa 6" air gap is provided. To prevent bodilyinjury, haz. ard to life, or property damage, the relief valve must be allowed to dischargewater in quantities shouldcircumstancesdemand. If the discharge pipe is not connected to a drain or other suitable i means, the water flow may causeproperty damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplingsor other restrictions.

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.

Must terminate at an adequate drain.

Must not haveany valve between the relief valve and tank.

AWARNING

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (I) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.

If after manually operating the valve, it fails to completely

reset and continues to release water, immediately close the

cold water inlet to the water heater, follow the draining

nstructions, and replace the temperature-pressure relief valve with a new one.

HOTCOLD

VALVE

RELIEF VALVE

[]

(Do not cap or plug)

6" AIR GAP

FLOOR ORAN I

RELIEF VALVE OPENING

"THIS WATER HEATER IS PROVIDED WITH A COMBINATION TEMPER- ATURE-PRESSURE RELIEF VALVE. FOR SAFE OPERATION OF THE

WATER HEATER, THE RELIEF VALVE(S) MUST NOT BE REMOVED FROM ITS DESIGNATED POINT OF INSTALLATION OR PLUGGED."

YOUR LOCAL 3UR_SDICT_ONALAUTHORITY,WH_LE MANDATING THE USE OF A TEMPERATURE-PRESSURE RELIEF VALVE COMPLYING

WITH ANSI Z21.22 AND ASME, MAY REQUIRE A VALVE MODEL DIF- FERENT FROM THE ONE FURNISHED WITH THE WATER HEATER.

COMPLIANCE WITH SUCH LOCAL REQUIREMENTS MUST BE SATIS-

FIED BY THE INSTALLER OR END USER OF THE WATER HEATER WITH A LOCALLY PRESCRIBED TEMPERATURE-PRESSURERELIEF

VALVE INSTALLED IN THE DESIGNATED OPENING IN THE WATER HEATER.

SEE MANUAL HEADING--"TEMPERATURE-PRESSURE RELIEF

VALVES" FOR INSTALLATION AND MAINTENANCE OF REUEF VALVE, DISCHARGE LINE AND OTHER SAFETY PRECAUTIONS.

12

Image 12
Contents For Your Safety AN Odorant is Added to the GAS Used by this Water HeaterWhat to do if YOU Smell GAS Safety Precautions AwarningSafety Precautions Acaution Contents Customer Responsibilities ProductMaterials and Basic Tools Needed Materials NeededInstallation Instructions Removing the Old Water HeaterAwarning AcautionInstallation Instructions contd Facts to Consider About LocationALL AIR from Inside Buildings ALL AIRInstallation Completed Using Sears Installation KIT Water PipingTemperature-Pressure Relief Valve Relief Valve OpeningWhen the water heater is in use Filling the Water HeaterVent Pipe Installation Venting contdGas Piping GAS Piping with Flexible Connector Sediment TrapContd Before Lighting the PilotOperating Instructions LightingCheck for Leaks Operating Instructions contd Whattodo if YousmellgasNot Force Temperature Regulation WaterService and Adjustment Tank Sediment CleaningBurner Cleaning Venting System InspectionService and Adjustment contd Start Up Conditions SMOKE/ODORWater vapor Smelly Water Strange SoundsAIR in HOT Water Faucets Little or no dissolved oxygen in the waterTroubleshooting Guide contd High Temperature Shut OFF SystemContd Not Enough or no HOT WaterLeakage Checkpoints Parts Order List 153.332161 39 Gal#38 Burner# Manual Warranty Improper venting

153.332319, 153.332363, 153.332419, 153.332111, 153.332161 specifications

Kenmore has established itself as a reputable brand in the realm of home appliances, and the model lineup including Kenmore 153.332319, 153.332111, 153.332463, 153.332419, and 153.332563 showcases a range of features designed for convenience and efficiency.

The Kenmore 153.332 series emphasizes energy efficiency, an essential factor in today’s eco-conscious world. These models are engineered to consume less electricity while maintaining optimal performance, reducing utility bills without compromising functionality.

One of the standout characteristics of these models is their advanced refrigeration technology. The multi-air flow system ensures even cooling throughout the refrigerator, preventing hotspots that can lead to spoilage. This feature is complemented by precise temperature controls, allowing users to adjust settings according to their storage needs, which is particularly beneficial for perishable goods.

In terms of storage, these models boast flexible shelving options. The tempered glass shelves are easily adjustable, catering to various sizes of food items and containers. The spacious door bins provide additional storage for condiments and beverages, enhancing organization and accessibility.

Another significant feature is the ice and water dispenser. Models like the 153.332463 and 153.332563 come equipped with advanced filtration systems that deliver clean drinking water and clear ice cubes. This feature not only adds convenience but also encourages healthier drinking habits.

The exterior design of these appliances is sleek and modern, often available in stainless steel finishes that complement any kitchen decor. The fingerprint-resistant coating minimizes smudges, allowing for easy maintenance and a pristine look.

Security and child safety are also key considerations in the design of these models. User-friendly locking mechanisms and alarm systems ensure that children cannot accidentally open the refrigerator, providing peace of mind for families.

The Kenmore series models feature high-quality construction and meticulous attention to detail. They are designed for long-lasting performance, backed by warranties that underscore the brand’s commitment to reliability.

In summary, Kenmore 153.332319, 153.332111, 153.332463, 153.332419, and 153.332563 are designed to meet the needs of modern households with their energy efficiency, advanced refrigeration technology, flexible storage options, convenience features, and robust design. These models exemplify Kenmore’s dedication to quality and user satisfaction, making them a valuable addition to any kitchen.