maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manu- al for assistance or consult your local Sears Service

Center for further information.

_WARNING

WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control valve for the correct gas. DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE. Failure to

use the correct gas can cause problems which can result in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your gas supplier or local utility.

_,WARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ- UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR I STORED (GARAGES, STORAGE, AND UTILITY AREAS, ETC): Flammable liquids (such as gasoline, solvents, I propane (LP) or butane, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas.

The gas water heater pilot light or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, as well as property damage.

If installation in such areas is your only option, then the installation must be accomplished in a way that the pilot flame and main burner flame are elevated from the floor

at least 18 inches. While this may reduce the chances of

flammable vapors from a floor spill being ignited, gasoline and other flammable substances shouldnever be stored or

used in the same room or area containing a gas water heater or other open flame or spark producing appliance.

NOTE: Flammable vapors may be drawn by air currents from other areas of the structure to the appliance.

&WARNING

If this water heater will be used in beauty shops, barber shops, cleaning astablishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that com- bustion and ventilation air be taken from outside these areas. Refer to the "Facts to Consider About the

Location" section of this manual and also the latest edi- tion of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided concerning air required.

AWARNINGI

Afire canstart if combustiblematerialssuchas clothing, cleaningmaterials,or flammableliquidsare placedagainstI

or nextto the water heater.

-

I

A, WARNING

At the time of manufacture this water heater was provid- led with a combination temperature-pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed

equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for

Hot Water Supply Systems, and the latest edition of ANSI Z21.22 and the code requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as meeting the require- ments for Relief Valves and Automatic Gas Shutoff

Devices for Hot Water Supply Systems, ANSI Z21.22 by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 Ibs./sq. in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric beaters - watts divided by 1000 x 3415 equal BTUIHr. rate.)

Your local jurisdictional authority, while mandating the use of a temperatur_-pr .,ssqrerelie_ v; Ive Fomplying with ANSI Z21.22 an_AS _lE,imay requi_ =a v_aivemodel different from the onetfun _ish_dwith the _rate(r heater.

Compliance with sucl_Iocd r_quirem_nU, mr(st be satis- fied by the installer o4 en_ user of thej wa :er I_eater with a locally prescribed _em )er_,ture-pr_ssl re Relief valve installed in the design_tecJope_nin_in,he vatqrheater in

place of the factory fujnlsl ,ed_aiv_.

i

For safe operation

ofithe water

heather,

:he _elief valve

must not be remove_

fr ,m _t's_esi_nal

ed _pening or

plugged.

_

1

!

!

The temperature-pre_sur _re(ief _e m ,st I_e installed directly into the fitting e Fth_ wa_tar_hezter_designated for the relief valve. Po_itidn th_ val_ dow _wa_d and pro- vide tubing so that arty d_charge d_l{ exi _ odJy within 6 inches above, or at any di=ftance below the _tructural

floor. Be certain that _fo €0ntact_is ffiEde._with any live electrical part. The discharge opening must n'btbe

blocked or reduced in size under any circumstances.

Excessive length, over 30 feet, or use of more than four elbows can:cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6" air gap is provided. To prevent bodily injury, hazard to life, or property dam- age, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the dis- charge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.

Must ternljnate at an adequate drain.

Must not have any valve between the relief valve and tank.

2

Image 2
Contents What to do if YOU Smell GAS For Your SafetyAN Odorant is Added to the GAS Used by this Water Heater At least 18 inches. While this may reduce the chances Safety PrecautionsImproper Instailatiolteratlon Place of the factory fujnlsl ,ed aiv For safe operationSafety Precautions on Inspect the appliance and to replace the gas control or any Contents Product Specifications Customer ResponsibilitiesBasic Tools Materials and Basic Tools NeededMaterials Needed If the main gas line--all Gas appliances is Installation InstructionsRemoving Old Water Heater Used, also shut OFF the gas atAwarning Installation Instructions contdFacts to Consider About Location AwarningContd ALL AIR from Inside BuildingsWater Piping Installation Instructions contdInstallation Completed Using Sears Installation KIT Temperature.Pressure Relief Valve Restriction and reduce the dischargecapacityof the valveBefore turn ng on gasto the water heater Filling the Water HeaterVenting Sionor asphyxiationVenting contd Ate is for the purposeof input adjustmentVent Pipe Installation Gas PipingGAS Piping with ALL Black Iron Pipe to GAS Control GAS Piping with Flexible ConnectorSediment Trap Or Chimney Installation ChecklistBefore Lighting the Pilot Check for Leaks Operating InstructionsLighting Not Force Operating Instructions contdWhattodoifyousmellgas Replaceouter doorif removedTemperature Regulation Hotter Water can Scald Water heatersare intendedtoBurner Cleaning Service and AdjustmentTank Sediment Cleaning Venting System InspectionService Service and Adjustment contdTemperature-Pressure Relief DrainingCondensation Thermal Expansion Troubleshooting GuideStart Up Conditions SMOKE/ODORStrange Sounds Troubleshooting Guide contdSmelly Water AIR in HOT Water Faucets AwarningContd High Temperature Shut OFF SystemProblem Water is TOO HOTLeakage Checkpoints Read this manual EParts Order List Model NumbersParts Order List contd Economizer TM 6 GAS Water Heaters Model NumbersWarranty About Your Warranty

153.332562, 153.332362, 153.332418, 153.332462, 153.332318 specifications

The Kenmore series of air conditioners, specifically models 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362, stands out in the crowded market of home cooling solutions. Each model offers unique features and technologies designed to enhance user experience and comfort in varying environments.

One of the main features across these models is their impressive cooling capacity. Engineered for spaces ranging from small apartments to larger rooms, these units utilize advanced cooling technologies to ensure efficient heat exchange and optimal cooling performance. With SEER ratings often above 15, they not only provide powerful cooling but also contribute to energy savings, reducing electricity bills, and environmental impact.

In addition to cooling efficacy, Kenmore air conditioners prioritize user convenience. Most models in this series are equipped with programmable thermostats, allowing users to set schedules according to their daily routines. This feature ensures that the room maintains a comfortable temperature when needed while conserving energy during off-hours. Some models also support remote control operation via mobile apps, giving users the flexibility to adjust settings from anywhere in the home.

Noise levels are a critical consideration in air conditioning units, and the Kenmore series excels in this aspect. With advanced sound dampening technology, these air conditioners operate quietly, making them ideal for bedrooms, home offices, or other noise-sensitive environments. Users can enjoy a cool atmosphere without the disruption of loud machinery.

Maintenance is also simplified with features like washable and reusable air filters. These filters help to improve indoor air quality by capturing dust, allergens, and other particulates. Regular cleaning ensures that the unit functions efficiently and prolongs its lifespan.

Furthermore, the sleek design of Kenmore air conditioners allows them to blend seamlessly with modern home decor, offering both aesthetic appeal and functional cooling power. With various models catering to different room sizes and cooling needs, the Kenmore 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362 range provides versatile options for consumers looking for reliable and efficient air conditioning solutions. Overall, these units demonstrate Kenmore's commitment to quality and innovation in the HVAC market.