Kenmore 153.332562 Installation Instructions contd, Facts to Consider About Location, Awarning

Page 9

Installation Instructions (cont'd)

Facts to Consider About the

Location

You should carefully choose an indoor location for the new water heater, because the placement is a very important consid- eration for the safety of the occupants in the building and for

the most economical use of the appliance. This water heater is not for use in mobile homes or outdoor installation.

Whether replacing an old water heater or putting the water

heater in a new location, the following critical points must be observed.

The location selected should be indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water

[iping system as possible. The water heater, as all water

eaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage.

_, CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplishedin sucha manner that if the tank or any connectionsshouldleak, the flow of water will not causedamageto the structure. When suchlocationscan- not be avoided,a suitable drain pan shouldbe installedunder the water heater, Drain pansare availableat your local Sears store. Such a drain pan must be not greater than 1'/2inches deep, have a minimum length and width of at least 2 inches greater than the water heater dimensionsand must be piped to an adequate drain.The pan must not restrict combustionair flow. Under on circumstancesis the manufacturer or Sears

be held liable for any water damage in connection with thi water heater,

The location selection must provide adequate clearances for ser- vicing and proper operation of the waterheater.

_WARNING

This water heater must not be installeddirectly on carpeting.

Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the applianceis installedin an alcoveor closet, the entire floor must be coveredby the panel, Failure to heed this warning may resultin afire hazard.

_,WARNING

Minimum clearances between the water heater and com- bestible or non-combustibleconstructionare I" at the sides and rear, 4" at the front, and 6" from the vent pipe. Clearance from the top of the jacket is 18" on most models. Note that a lesserdimensionmay be allowed on some models. Referto the

label on the water heater adjacentto the gascontrol valve for all clearances.

VENTILATION

I

_I _w

_

i_1 _

 

 

AIR

 

i

i

 

4" IMIN '

I

_

I

TOP V EVe

 

 

,,

 

 

L

OF CLOSET

 

TOP Vl

I" NIN.

L

 

W_THOUT DOOR

OF

 

 

_, MAX

 

WITH DOOR

 

 

FRONT VIE%V

 

 

 

 

 

 

OF DOOR

 

 

 

 

 

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE, AND UTILITY AREAS, ETC): Flammable liquids(suchas gasoline,solvents,propane(LP) or butane, etc.), all of which emit flammable vapors, may be improperlystoredor usedin suchasea_ The gaswater heater

pilot light or main bumer can ignite suchvapor_ The resulting flashbackand Ere can causedeath or serious burnsto anyonem the area, aswell aspropertydamage.

If installationin suchareasis youronly option,then the installa.

tion must be accomplishedin a way that the pilot flame and main burnerflame are elevatedfrom the floor at least 18inches.

While this may reduce the chancesof 8ammable vaporsfrom a floor spillbeing ignited,gasolineand other flammable substances shouldneverbe stored or used in the same room or area con-

talnin8 a gaswater heater or other open flame or sparkproduc- ingappliance.

NOTE: Flammable vaporsmay be drawn by air currentsfrom other areasof the structureto the appliance.

AWARNING

Propellantsof aerosol spraysand volatile compounds,(clean- ers, chlorine basedchemicals,refrigerants, etc.) in addition to beinghighlyflammable in many cases,will also changeto cor- rosive hydrochloric acid when exposed to the combustion products of the water heater, The results can be hazardous, and alsocauseproduct failure.

[ Figure I ]

A,FDUCT

AWARNING

A__gaswater heater cannot operate properly without the cor- rect amount of air for combu_on. Do not installin a confined

area sucha deset, unlessyou provideair as shownin the "Facts to Consider About the Location" section. Never obstruct the

flow of ventilation air. If you haveany doubtsor questionsat all, callyour gascompany.Failureto providethe proper amount of combustionair can result in a Ere or explosionand can cause

DEATH, SERIOUS BODILY INJUR_,OR PROPERTY DAMAGE.

AWARNING

If this water heater will be usedin beauty shops,barber shops,

cleaning establishments, or self.service laundries with dry

cleaningequipment, it is imperative that the water heater or water heaters be installed so that combustionand ventilation air be taken from outsidethese areas. Referto the "Facts to Consider About the Location" sectionof this manual and also the latest edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specificsprovidedconcerning

aik required.

I

Image 9
Contents For Your Safety AN Odorant is Added to the GAS Used by this Water HeaterWhat to do if YOU Smell GAS Improper Instailatiolteratlon Safety PrecautionsAt least 18 inches. While this may reduce the chances Place of the factory fujnlsl ,ed aiv For safe operationSafety Precautions on Inspect the appliance and to replace the gas control or any Contents Customer Responsibilities Product SpecificationsMaterials and Basic Tools Needed Materials NeededBasic Tools Removing Old Water Heater Installation InstructionsIf the main gas line--all Gas appliances is Used, also shut OFF the gas atFacts to Consider About Location Installation Instructions contdAwarning AwarningALL AIR from Inside Buildings ContdInstallation Instructions contd Installation Completed Using Sears Installation KITWater Piping Restriction and reduce the dischargecapacityof the valve Temperature.Pressure Relief ValveVenting Filling the Water HeaterBefore turn ng on gasto the water heater Sionor asphyxiationVent Pipe Installation Ate is for the purposeof input adjustmentVenting contd Gas PipingGAS Piping with Flexible Connector Sediment TrapGAS Piping with ALL Black Iron Pipe to GAS Control Installation Checklist Before Lighting the PilotOr Chimney Operating Instructions LightingCheck for Leaks Whattodoifyousmellgas Operating Instructions contdNot Force Replaceouter doorif removedHotter Water can Scald Water heatersare intendedto Temperature RegulationTank Sediment Cleaning Service and AdjustmentBurner Cleaning Venting System InspectionTemperature-Pressure Relief Service and Adjustment contdService DrainingStart Up Conditions Troubleshooting GuideCondensation Thermal Expansion SMOKE/ODORSmelly Water Troubleshooting Guide contdStrange Sounds AIR in HOT Water Faucets AwarningProblem High Temperature Shut OFF SystemContd Water is TOO HOTRead this manual E Leakage CheckpointsModel Numbers Parts Order ListEconomizer TM 6 GAS Water Heaters Model Numbers Parts Order List contdAbout Your Warranty Warranty

153.332562, 153.332362, 153.332418, 153.332462, 153.332318 specifications

The Kenmore series of air conditioners, specifically models 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362, stands out in the crowded market of home cooling solutions. Each model offers unique features and technologies designed to enhance user experience and comfort in varying environments.

One of the main features across these models is their impressive cooling capacity. Engineered for spaces ranging from small apartments to larger rooms, these units utilize advanced cooling technologies to ensure efficient heat exchange and optimal cooling performance. With SEER ratings often above 15, they not only provide powerful cooling but also contribute to energy savings, reducing electricity bills, and environmental impact.

In addition to cooling efficacy, Kenmore air conditioners prioritize user convenience. Most models in this series are equipped with programmable thermostats, allowing users to set schedules according to their daily routines. This feature ensures that the room maintains a comfortable temperature when needed while conserving energy during off-hours. Some models also support remote control operation via mobile apps, giving users the flexibility to adjust settings from anywhere in the home.

Noise levels are a critical consideration in air conditioning units, and the Kenmore series excels in this aspect. With advanced sound dampening technology, these air conditioners operate quietly, making them ideal for bedrooms, home offices, or other noise-sensitive environments. Users can enjoy a cool atmosphere without the disruption of loud machinery.

Maintenance is also simplified with features like washable and reusable air filters. These filters help to improve indoor air quality by capturing dust, allergens, and other particulates. Regular cleaning ensures that the unit functions efficiently and prolongs its lifespan.

Furthermore, the sleek design of Kenmore air conditioners allows them to blend seamlessly with modern home decor, offering both aesthetic appeal and functional cooling power. With various models catering to different room sizes and cooling needs, the Kenmore 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362 range provides versatile options for consumers looking for reliable and efficient air conditioning solutions. Overall, these units demonstrate Kenmore's commitment to quality and innovation in the HVAC market.