Kenmore 153.332562, 153.332462 Inspect the appliance and to replace the gas control or any

Page 4

Safety Precautions

a, WARNING

The water heater with draft hood installed must be prop- erly vented to a chimney which terminates outdoors. Never operate the water heater unless it is vented to the I

I outdoors

and has adequate air supply to avoid risks

of_

I improper

operation, explosion or asphyxiation.

I

&WARNING

Minimum dearences between the water heater and com- bustible or non-combustible construction are I" at the sides and rear, 4" at the front, and 6" from the vent pipe. Clearance from the top of the jacket is 18" on most mod- els. Note that a lesser dimension may be allowed on some models. Refer to the label on the water heater adjacent to the _as control valve for all clearances.

&WARNINGI

Do not use this appliance if any part of it has been under water. Immediately call a Sears Service Technician to

inspect the appliance and to replace the gas control or any

_art of the burner system wh ch has been under water.

_" WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possi- bility of injury under these conditions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dis- hwasher or washing machine). If'hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near I the faucet at the time it is open.

A, WARNING

INSULATING JACKETS: When installing an external water heater insulation iacket on a gas water heater:

DO NOT cover the temperature-pressure relief valve.

DO NOT put insulation over any part of the top of the gas water heater,

DO NOT put insulation over the gas control valve or gas control valve/burner cover, or any access areas to the burner.

DO NOT let insulation around the gas water heater to get within 8 inches of the floor (air must get to the burner).

DO NOT cover or remove operating instructions, and safety related warning labels and materials affixed to the water heater.

Failure to heed this will result in the possibility of a fire or explosion.

ACAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of

the water heater must be accomplished in sucha manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are avail- able at your local Sears store. Such a drain pan must be not greater than I _ inches deep, have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate !drain. The pan must not restrict combustion air flow.

I Under no circumstances is the manufacturer or Sears to i be held liable for any water damage in connection with I this water heater.

Image 4
Contents AN Odorant is Added to the GAS Used by this Water Heater For Your SafetyWhat to do if YOU Smell GAS Safety Precautions Improper InstailatiolteratlonAt least 18 inches. While this may reduce the chances Place of the factory fujnlsl ,ed aiv For safe operationSafety Precautions on Inspect the appliance and to replace the gas control or any Contents Product Specifications Customer ResponsibilitiesMaterials Needed Materials and Basic Tools NeededBasic Tools Installation Instructions Removing Old Water HeaterIf the main gas line--all Gas appliances is Used, also shut OFF the gas atInstallation Instructions contd Facts to Consider About LocationAwarning AwarningContd ALL AIR from Inside BuildingsInstallation Completed Using Sears Installation KIT Installation Instructions contdWater Piping Temperature.Pressure Relief Valve Restriction and reduce the dischargecapacityof the valveFilling the Water Heater VentingBefore turn ng on gasto the water heater Sionor asphyxiationAte is for the purposeof input adjustment Vent Pipe InstallationVenting contd Gas PipingSediment Trap GAS Piping with Flexible ConnectorGAS Piping with ALL Black Iron Pipe to GAS Control Before Lighting the Pilot Installation ChecklistOr Chimney Lighting Operating InstructionsCheck for Leaks Operating Instructions contd WhattodoifyousmellgasNot Force Replaceouter doorif removedTemperature Regulation Hotter Water can Scald Water heatersare intendedtoService and Adjustment Tank Sediment CleaningBurner Cleaning Venting System InspectionService and Adjustment contd Temperature-Pressure ReliefService DrainingTroubleshooting Guide Start Up ConditionsCondensation Thermal Expansion SMOKE/ODORTroubleshooting Guide contd Smelly WaterStrange Sounds AIR in HOT Water Faucets AwarningHigh Temperature Shut OFF System ProblemContd Water is TOO HOTLeakage Checkpoints Read this manual EParts Order List Model NumbersParts Order List contd Economizer TM 6 GAS Water Heaters Model NumbersWarranty About Your Warranty

153.332562, 153.332362, 153.332418, 153.332462, 153.332318 specifications

The Kenmore series of air conditioners, specifically models 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362, stands out in the crowded market of home cooling solutions. Each model offers unique features and technologies designed to enhance user experience and comfort in varying environments.

One of the main features across these models is their impressive cooling capacity. Engineered for spaces ranging from small apartments to larger rooms, these units utilize advanced cooling technologies to ensure efficient heat exchange and optimal cooling performance. With SEER ratings often above 15, they not only provide powerful cooling but also contribute to energy savings, reducing electricity bills, and environmental impact.

In addition to cooling efficacy, Kenmore air conditioners prioritize user convenience. Most models in this series are equipped with programmable thermostats, allowing users to set schedules according to their daily routines. This feature ensures that the room maintains a comfortable temperature when needed while conserving energy during off-hours. Some models also support remote control operation via mobile apps, giving users the flexibility to adjust settings from anywhere in the home.

Noise levels are a critical consideration in air conditioning units, and the Kenmore series excels in this aspect. With advanced sound dampening technology, these air conditioners operate quietly, making them ideal for bedrooms, home offices, or other noise-sensitive environments. Users can enjoy a cool atmosphere without the disruption of loud machinery.

Maintenance is also simplified with features like washable and reusable air filters. These filters help to improve indoor air quality by capturing dust, allergens, and other particulates. Regular cleaning ensures that the unit functions efficiently and prolongs its lifespan.

Furthermore, the sleek design of Kenmore air conditioners allows them to blend seamlessly with modern home decor, offering both aesthetic appeal and functional cooling power. With various models catering to different room sizes and cooling needs, the Kenmore 153.332318, 153.332562, 153.332418, 153.332462, and 153.332362 range provides versatile options for consumers looking for reliable and efficient air conditioning solutions. Overall, these units demonstrate Kenmore's commitment to quality and innovation in the HVAC market.