Kenmore 153.330501, 153.330451, 153.330751 Operating Instructions, Temperature Regulation

Page 19

Operating Instructions

Temperature Regulation

Due to the nature of the typical gas water heater, the water rem- perature in certain situations may vary up to 30°F higher or lower at the point of use such as, bathtubs, showers, sink, etc.

This means that when the temperature adjustment dial is set at the mark approximating 120°F, the actual water temperature at any hot water tap could be as high as 150°F or as low as 90°E

Any water heater's intended purpose is to heat water. Hot water is needed for cleaning (bodies, dishes, clothing). Hot water will

present a scald hazard. Depending on the time element, and the

people involved (normaladults, children, toddlers, elderly, infirm, etc.) scalding may occur at different temperatures.

AWARNING

HOTTER WATER CAN SCALD:Water heatersareintendedto producehot waten Water heatedto a temperature whichwill satisfydutheswashing,dishwashing,and othersanitizing needs canscaldand permanentlyinjureyou uponcontact.Some peo-

ple am more likelyto be permanentlyinjured_ hot water than others.Theseincludetheelderly,children,themllrm,or physical- ly/montally handicappedIf. anyoneusinghotwater in yourhome fitsintoone ofthesegroupsor if there isa localcedeor state law requiringa certaintemperatorewater at the hotwatertap, then you musttake specialprecautionsIn. additionto usingthe lowest possibletemperature settingthat satisfiesyour hot vam_ needs, a meanssuchas a mixingvalve,shouldbe usedat the hot water tapsusedby these peopleor at the water heater,Mixingvalves are availableat plumbingsupplyor hardwarestore_Followman- ufacturers instructionsfor installation of the valves. Before changing the factory setting on the thermostat, read the 'q'emperutureRegulation"sectionin this manual.

AWARNING

Never allow small children to usea hot vraJ_rtap, or to draw their own bath water. Never leavea childor handicappedper- ann unattendedin a bathtub or shower,

The thermostat of this water heater has been factory set at its

lowest position, to reduce the risk of scald injury. It is adjustable and must be reset to the desired temperature setting. The mark

(A)indicative of approximately 120°F is the preferred starting point. Some states have a requirement for a lower setting. If you need hotter water, follow directions for temperature adjustment, but beware of the warnings in this section.

(cont'd)

Turn the water temperature dial clockwise__f'-_) to decrease the temperature, or counterclockwise (€ _ "_) to increase the temperature.

PILOT

LIGHTING - Set here before lighting pilot.

- Is a thermostat setting of approximately 120°F, which will supply hot water at the most economical temperatures. The tempera-

ture adjustment knob can be turned lower than 120°F if desired.

A - Is a thermostat setting of approximately 130°E

B - Is a thermostat setting of approximately 140°E

C - Is a thermostat setting of approximately 150°E

VERY HOT - Is a thermostat setting of 160°E It is recom- mended that the dialbe set lower whenever

possible.

NOTE: Water temperature range of 120°--140°F recom-

mended by most dishwasher manufacturers.

AWARNING

Shouldoverheating occur or the gas supplyfail to shut off, turn "OFF" the manualgascontrolvalveto the appliance.

19

Image 19
Contents AWARNING..I For Your SafetyAN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASAwarningi Safety PrecautionsAwarning Damage m connection with this water heater AWAIRNING1Contents Customer ResponSibilities Product SpecificationsPipe dope or Teflon Tape Materials and Basic Tools NeededMaterials Needed Basic ToolsRemoving the Old Water Heater Installation Instruc i hsAcaution DEATH, SERIOUSBODILYINJUR,OR Propertydamage Installation Instructions contdFacts to Consider About Location AwarningALL AIR from Inside Buildings Installation InstrudionS C6ntdALL AIR from Outdoors see Figures Water Piping Installation Completed Using Sears Installation KITHotter Water can SCAL. Water heatersare intendedto No Valveor otherobstructionisto be placedbetweenthe relief Installation InstructiOns cdntdTemperature-Pressure Relief Vave With any ve e ecical part. The dschargeopenng mustnot beNever usethiswater h Installation Instructions contdFilling the Water Heater VentingVent Pipe Installation Installation Instru ti6hs ontdVenting contd GAS Piping with ALL Black Iron Pipe to GAS Control Installation InstructionsGAS Piping with Flexible Connector ContdCheck for Leaks Installation InstructionsInstallation Checklist ContdLighting Operating InstructionsBeforelighting PROPANELP. GAS Water Heaters Replaceouterdoorif removed Operating Instructions contdWhattodo if Yousmellgas Not ForceOperating Instructions Temperature RegulationBurner Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningService Service and Adjustment contdTemperature-Pressure Relief Drain Valve Washer ReplacementSMOKE/ODOR Troubleshooting GuideStart Up Conditions CondensationAIR in HOT Water Faucets Troubleshooting Guide contdOperational Conditions Smelly WaterNot Enough or no HOT Water High Temperature Shut OFF System Water is TOO HOTAwarning LA Cautioni Leakage CheckpointsParts Order List Parts Order List contd Power Miser TM 12 GAS Water Heaters Model NumbersAbout Your Warranty Warranty

153.3304OI, 153.330551, 153.330451, 153.330751, 153.330701 specifications

The Kenmore 153 series of dehumidifiers, including models 153.330501, 153.330701, 153.330451, 153.330751, and 153.330551, represent a versatile lineup designed to tackle moisture control in residential spaces. These dehumidifiers are essential appliances for maintaining optimal humidity levels, which can contribute to improved air quality and comfort in homes, especially in areas prone to dampness.

One of the main features of the Kenmore 153 series is their considerable moisture removal capacity. These models are engineered to effectively extract moisture from the air, with capacities ranging from 30 to 70 pints per day, allowing them to handle spaces of various sizes from small rooms to larger basements. This makes them ideal for both typical home environments and more humid settings.

Technologically, the Kenmore 153 series includes advanced humidistats that allow for precise humidity control. This feature enables users to set their desired humidity levels, ensuring that the dehumidifier operates only when necessary, helping to save on energy costs. The series also includes built-in continuous drainage options, which can be a convenient solution for prolonged use, eliminating the need to frequently empty the water tank.

Another noteworthy characteristic is their user-friendly interface. Most models in this series feature digital displays for easy monitoring, along with simple controls that make adjusting settings straightforward. This focus on usability is complemented by quiet operation, ensuring that the dehumidifiers can run unobtrusively in the background without causing significant noise disruption.

Energy efficiency is a crucial aspect of the Kenmore 153 line, as the models are designed to meet Energy Star standards. This means they consume less energy while delivering effective performance, making them an environmentally friendly choice in moisture management.

Additionally, these models often come equipped with features such as washable filters that help to reduce airborne allergens and ensure cleaner air. This is particularly beneficial for individuals with allergies or respiratory issues, creating a healthier indoor environment.

In summary, the Kenmore 153.330501, 153.330701, 153.330451, 153.330751, and 153.330551 dehumidifiers combine powerful moisture removal capabilities with advanced technologies, user-friendly features, and energy efficiency. They are a valuable investment for any homeowner looking to improve air quality and combat humidity-related issues effectively.