Kenmore 153.330551, 153.330451 Water Piping, Hotter Water can SCAL. Water heatersare intendedto

Page 11

Installation Instructions (cont'd)

Water Piping

_WARNING

HOTTER WATER CAN SCAL_. Water heatersare intendedto

i_. uce hot woter..Water heatedto a temperaturewhichwill satisfyclotheswashln&dishwashing,and other sanitizingneeds can scaldand permanentlyinjureyou uponcontact.Some peo- ple are more IE_qyto be permanentlyinjuredbyhot water than others.Theseindudetheelderigchildren,the inlirm,or physicag

ly/mentallyhandicappedIf. anyoneusinghot water inyour home Ett intoone ofthesegroupsor ifthere isa localcodeor statelaw requiringa certaintemperaturewaterat the hot watertap,then youmust take specialprecaution_In additionto usingthe lowest possibletemperature settingthat satisfiesyourhot w_r needs,

ameanssuchas a mixingvalve,should be usedat the hot water tapsusedby these peopleor at the water he_er. Mixingvalves are availableat plumbingsupplyor hanfwerestere_ Followman- ufacturers instructionsfor installationof the valves•Before

changing the factory setting on the thermostat, read the '_TemperatureRegulation"sectionin this manual.

Look at the top cover of the water heater. The cold water inlet is markedcold. Put two or three turns of teflon tape

around the threaded end of _e threaded-to-sweat coupling and around both ends of the 3A threaded nipple. Using flexi-

ble connectors, connect the cold water pipe to the coldwater inlet of the water heater.

NOTE." This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss

can be accomplished by insulating the hot water lines

from the water heater.

 

 

INSTALLATION

COMPLETED

USING

 

 

 

SEARS INSTALLATION

KIT

 

HOT

OUTLET

FLEXIBLE

WATER

COLD

INLET

TO

HOUSE

CONNECTORS

WATER

LINE

This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance.

If a water heater is installed in a closed water supply system; such as one having a back-flow preventer, check valve, water meter with a check valve, etc.., in the cold water supply; means

shall be provided to control thermal expansion. Contact the

local utility or local Sears Service Center on how to control this situation.

NOTE: To protect against untimely corrosion of hot and cold water fitdngs_ it is strongly recommended that all-elec- tric unions or couplings be installed on this water heater when connected to copper pipe.

The iUustration shows the attachment of the water _iping to the water heater. The water heater is equipped with 3A water con- nections.

NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter m the cold water inlet connec- tion. Do not solder the cold water supply line directly to the cold water inlet• It will harm the dip tube and damage the tanL

Look at the top cover of the water heater. The water outlet is marked hot. Put two or three turns of teflon tape around the

threaded end of the threaded-to-sweat coupling and around both ends of the 3A threaded nipple. Using fexible connec-

tors, connect the hot water pipe to the hot water outlet on the water heater.

THREADED TO

SWEAT COUPLING

THREADED TO SWEAT COUPLING

--3/4" THREADED H EAT TRAP

--TEPIPEEATURE-

PRESSURE

RELIEF VALVE

--DISCHARGE

PIPE (Do not cap or plus)

%

--6"AIR GAP

FLOOR DRAIN

11

Image 11
Contents AWARNING..I For Your SafetyAN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASAwarningi Safety PrecautionsAwarning Damage m connection with this water heater AWAIRNING1Contents Customer ResponSibilities Product SpecificationsPipe dope or Teflon Tape Materials and Basic Tools NeededMaterials Needed Basic ToolsAcaution Installation Instruc i hsRemoving the Old Water Heater DEATH, SERIOUSBODILYINJUR,OR Propertydamage Installation Instructions contdFacts to Consider About Location AwarningALL AIR from Outdoors see Figures Installation InstrudionS C6ntdALL AIR from Inside Buildings Hotter Water can SCAL. Water heatersare intendedto Installation Completed Using Sears Installation KITWater Piping No Valveor otherobstructionisto be placedbetweenthe relief Installation InstructiOns cdntdTemperature-Pressure Relief Vave With any ve e ecical part. The dschargeopenng mustnot beNever usethiswater h Installation Instructions contdFilling the Water Heater VentingVenting contd Installation Instru ti6hs ontdVent Pipe Installation GAS Piping with ALL Black Iron Pipe to GAS Control Installation InstructionsGAS Piping with Flexible Connector ContdCheck for Leaks Installation InstructionsInstallation Checklist ContdBeforelighting PROPANELP. GAS Water Heaters Operating InstructionsLighting Replaceouterdoorif removed Operating Instructions contdWhattodo if Yousmellgas Not ForceOperating Instructions Temperature RegulationBurner Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningService Service and Adjustment contdTemperature-Pressure Relief Drain Valve Washer ReplacementSMOKE/ODOR Troubleshooting GuideStart Up Conditions CondensationAIR in HOT Water Faucets Troubleshooting Guide contdOperational Conditions Smelly WaterAwarning High Temperature Shut OFF System Water is TOO HOTNot Enough or no HOT Water LA Cautioni Leakage CheckpointsParts Order List Parts Order List contd Power Miser TM 12 GAS Water Heaters Model NumbersAbout Your Warranty Warranty

153.3304OI, 153.330551, 153.330451, 153.330751, 153.330701 specifications

The Kenmore 153 series of dehumidifiers, including models 153.330501, 153.330701, 153.330451, 153.330751, and 153.330551, represent a versatile lineup designed to tackle moisture control in residential spaces. These dehumidifiers are essential appliances for maintaining optimal humidity levels, which can contribute to improved air quality and comfort in homes, especially in areas prone to dampness.

One of the main features of the Kenmore 153 series is their considerable moisture removal capacity. These models are engineered to effectively extract moisture from the air, with capacities ranging from 30 to 70 pints per day, allowing them to handle spaces of various sizes from small rooms to larger basements. This makes them ideal for both typical home environments and more humid settings.

Technologically, the Kenmore 153 series includes advanced humidistats that allow for precise humidity control. This feature enables users to set their desired humidity levels, ensuring that the dehumidifier operates only when necessary, helping to save on energy costs. The series also includes built-in continuous drainage options, which can be a convenient solution for prolonged use, eliminating the need to frequently empty the water tank.

Another noteworthy characteristic is their user-friendly interface. Most models in this series feature digital displays for easy monitoring, along with simple controls that make adjusting settings straightforward. This focus on usability is complemented by quiet operation, ensuring that the dehumidifiers can run unobtrusively in the background without causing significant noise disruption.

Energy efficiency is a crucial aspect of the Kenmore 153 line, as the models are designed to meet Energy Star standards. This means they consume less energy while delivering effective performance, making them an environmentally friendly choice in moisture management.

Additionally, these models often come equipped with features such as washable filters that help to reduce airborne allergens and ensure cleaner air. This is particularly beneficial for individuals with allergies or respiratory issues, creating a healthier indoor environment.

In summary, the Kenmore 153.330501, 153.330701, 153.330451, 153.330751, and 153.330551 dehumidifiers combine powerful moisture removal capabilities with advanced technologies, user-friendly features, and energy efficiency. They are a valuable investment for any homeowner looking to improve air quality and combat humidity-related issues effectively.