Kenmore 153.3304OI, 153.330451, 153.330501, 153.330751, 153.330701, 153.330551 owner manual Awarning

Page 3

Safety Precautions

A, WARNING

A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a

confined area such a closet, unless you provide air as shown In the "Facts to Consider About the Location" sec-

tion. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas company. Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH

SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

&WARNING

This water heater must not be installed directly on car- peting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.

&WARNING

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- peraturo which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physicallylmen- tally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addi- tion to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufac- turers instructions for installation of the valves. Before changing the factory setting on the thermostat, reed the "Temperature Regulation" section in this manual.

A,WARNING

Soot build-up indicates a problem that requires correc- tion before further use. Turn "OFF" gas to water heater and leave "OFF" until repairs are made, because failure to correct the cause of the sooting can result in a fire or

explosion causing DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

AWARNING

VENT DAMPERS - Any vent damper, whether it is operat- ed thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water

heaters having thermal efficiency in excess of 80% may )roduce a relatively low flue gas temperature. Such tem-

_atures may not be high enough to properly open ther- _ally operated vent dampers. This would cause spillage of

flue gases and may cause carbon monoxide poisoning. Vent dampers must bear evidence of certification as com-

plying with the latest edition of American National Standard ANSI Z21.68 (ANSI Z21.66 & 67, respectively,

cover electrically and mechanically actuated vent dampers). Before installation of any vent damper, consult

your local Sears Service Center or the gas utility for fur- ther information.

AWARNING

The appliance and its individual shutoff vaive must be dis- connected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of ½ pound per square inch (3.$kPa).

The appliance must be isolated from the gas supply pip- ing system by closing its individual manual shutoff valve

during any pressure testing of the gas supply piping sys- tem at test pressures equal or less than _ pound per square inch (3.SkPa).

AWARNING

BEFORE LIGHTING [PROPANE (L.P.) GAS WATER

HEATERS]: Propane (I-R) gas is heavier than air. Should there be a leak in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumula- tion of this gas. Before attempting to light or relight the water heater's pilot or turning on a nearby electrical light switch, be absolutely sure there is no accumulated gas in the area. Search for odor of gas by sniffing at ground level in the vicinity of the appliance. If odor is detected, follow steps indicated at "For Your Safety" on the cover page of this manual then leave the premises.

AWARNING

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigera-

tor and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compounds which are potentially corrosive.

A, WARNING

Obstructed or deteriorated vent systems may present a

serious heath risk or asphyxiation.

Safety Precautions continued on page 4

3

Image 3
Contents AWARNING..I For Your SafetyAN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASAwarningi Safety PrecautionsAwarning Damage m connection with this water heater AWAIRNING1Contents Customer ResponSibilities Product SpecificationsPipe dope or Teflon Tape Materials and Basic Tools NeededMaterials Needed Basic ToolsInstallation Instruc i hs Removing the Old Water HeaterAcaution DEATH, SERIOUSBODILYINJUR,OR Propertydamage Installation Instructions contdFacts to Consider About Location AwarningInstallation InstrudionS C6ntd ALL AIR from Inside BuildingsALL AIR from Outdoors see Figures Installation Completed Using Sears Installation KIT Water PipingHotter Water can SCAL. Water heatersare intendedto No Valveor otherobstructionisto be placedbetweenthe relief Installation InstructiOns cdntdTemperature-Pressure Relief Vave With any ve e ecical part. The dschargeopenng mustnot beNever usethiswater h Installation Instructions contdFilling the Water Heater VentingInstallation Instru ti6hs ontd Vent Pipe InstallationVenting contd GAS Piping with ALL Black Iron Pipe to GAS Control Installation InstructionsGAS Piping with Flexible Connector ContdCheck for Leaks Installation InstructionsInstallation Checklist ContdOperating Instructions LightingBeforelighting PROPANELP. GAS Water Heaters Replaceouterdoorif removed Operating Instructions contdWhattodo if Yousmellgas Not ForceOperating Instructions Temperature RegulationBurner Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningService Service and Adjustment contdTemperature-Pressure Relief Drain Valve Washer ReplacementSMOKE/ODOR Troubleshooting GuideStart Up Conditions CondensationAIR in HOT Water Faucets Troubleshooting Guide contdOperational Conditions Smelly WaterHigh Temperature Shut OFF System Water is TOO HOT Not Enough or no HOT WaterAwarning LA Cautioni Leakage CheckpointsParts Order List Parts Order List contd Power Miser TM 12 GAS Water Heaters Model NumbersAbout Your Warranty Warranty

153.3304OI, 153.330551, 153.330451, 153.330751, 153.330701 specifications

The Kenmore 153 series of dehumidifiers, including models 153.330501, 153.330701, 153.330451, 153.330751, and 153.330551, represent a versatile lineup designed to tackle moisture control in residential spaces. These dehumidifiers are essential appliances for maintaining optimal humidity levels, which can contribute to improved air quality and comfort in homes, especially in areas prone to dampness.

One of the main features of the Kenmore 153 series is their considerable moisture removal capacity. These models are engineered to effectively extract moisture from the air, with capacities ranging from 30 to 70 pints per day, allowing them to handle spaces of various sizes from small rooms to larger basements. This makes them ideal for both typical home environments and more humid settings.

Technologically, the Kenmore 153 series includes advanced humidistats that allow for precise humidity control. This feature enables users to set their desired humidity levels, ensuring that the dehumidifier operates only when necessary, helping to save on energy costs. The series also includes built-in continuous drainage options, which can be a convenient solution for prolonged use, eliminating the need to frequently empty the water tank.

Another noteworthy characteristic is their user-friendly interface. Most models in this series feature digital displays for easy monitoring, along with simple controls that make adjusting settings straightforward. This focus on usability is complemented by quiet operation, ensuring that the dehumidifiers can run unobtrusively in the background without causing significant noise disruption.

Energy efficiency is a crucial aspect of the Kenmore 153 line, as the models are designed to meet Energy Star standards. This means they consume less energy while delivering effective performance, making them an environmentally friendly choice in moisture management.

Additionally, these models often come equipped with features such as washable filters that help to reduce airborne allergens and ensure cleaner air. This is particularly beneficial for individuals with allergies or respiratory issues, creating a healthier indoor environment.

In summary, the Kenmore 153.330501, 153.330701, 153.330451, 153.330751, and 153.330551 dehumidifiers combine powerful moisture removal capabilities with advanced technologies, user-friendly features, and energy efficiency. They are a valuable investment for any homeowner looking to improve air quality and combat humidity-related issues effectively.