Service and Adjustment (cont'd)

Draining

The water heater should be drained if being shut down during

freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.

Turn the gas control knob to the "OFF" position. CLOSE the cold water inlet valve to the water heater.

OPEN a nearby hot water faucet and leave open to allow for

draining.

Connect a hose to the drain valve and terminate to an ade-

quate drain.

OPEN the water heater drain valve to allow for tank

draining.

NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be

left open with hose connected allowing water to terminate

to an adequate drain. Close the drain valve.

Follow instructions in the "Filling The Water Heater" section.

Follow the lighting instructions in the "Lighting" section to restart the water heater.

Temperature-Pressure Relief

AWARNING

When checkingthe temperature-pressurereliefvalveopera- tion, make sure that (I) no one is in front of or around the outlet of the temperature-pressurereliefvalvedischargeline, and (2) that the water manuallydischargedwill not causeany property damagebecausethe water may be extremely hot.

If after manually operating the valve, it fails to completely reset and continuesto release water, immediately closethe cold water inlet to the water heater, follow the draining

instructions, and replace the temperature-pressure relief valvewith a new one.

Housekeeping

Vacuum around base of water heater for dust, dirt, and lint on a

regular basis.

Combustible materials such as clothing, cleaning materials, or

flammable liquids, etc. must not be placed against or adjacent to the water heater.

To insure sufficient ventilation and combustion air supply, prop- er clearances from the water heater must be maintained at all times.

Valve Operation

The temperature-pressure relief valve must be manually operated at [east once a year.

TEMPERATURE-PRESSURE

Service

Before calling for repair service, read the Start Up Conditions

and Operational Conditions found in the Troubleshooting Guide of this manual.

If a condition persists or you are uncertain about the operation

of the water heater, let a qualified person check it out.

Contact SEARS Repair Services at 1-800-4-MY-HOME

(1-800-469-4663).

DISCHARGE PIPE

Failure to install and maintain a new properly listed tempera- ture-pressure relief valve will release the manufacturer from any claim which might result from excessive temperature or pressure.

AWARNING

If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal

expansion. Your water heater may have a check valve installed in the water line or a water meter with a check

valve. Consult the Sears Service Center for further informa-

tion. Do not plug the temperature-pressure relief valve.

22

Image 22
Contents For Your Safety What to do if YOU Smell GASSafety Precautions Serious BodilyAwarning Ifro Contents Specifications Customer ResponsibilitiesMaterials Needed Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterTypical Installation Installation Instructions contdAwarning Facts to Consider About Location AcautionCombustion Air Room InstallationVentilation For Appliances Located in Unconfined Spaces Water Piping Temperature-Pressure Relief Valve Relief Valve OpeningFilling the Water Heater Vent Pipe InstallationVenting Inches Venting contdSquare DEATH, Serious Bodily INJUR, or Property DamageGas Piping contd ContdGAS Piping with Before Lighting the Pilot Installation ChecklistModel Rating Plate Lighting Operating InstructionsCheck for Leaks Not Force Operating Instructions contdWhattodoif Yousmellgas PilotburnerTemperature Regulation Hotierwatercan SCALDWater heatersare intendedtoBurner Cleaning Service and AdjustmentTank Sediment Cleaning Venting System InspectionDraining Service and Adjustment contdService HousekeepingStart Up Conditions Troubleshooting GuideStrange Sounds Troubleshooting Guide contd Start Up Conditions contdNot Enough or no HOT Water High Temperature Shut OFF SystemWater is TOO HOT Leakage Checkpoints Primary anode rod fitting may be leakingPage Page Page Parts Order List Parts Order List contd Kenmorecommercialgaswater Heaters Model NumbersWarranty

153.337002, 153.337072 specifications

The Kenmore 153.337072 and 153.337002 represent a duo of high-efficiency window air conditioning units that have become popular choices for consumers seeking effective cooling solutions. Engineered with modern technology, these models promise to deliver optimal performance while maintaining energy efficiency.

One of the standout features of the Kenmore 153.337072 is its dual cooling and heating functionality. This versatility allows it to not only cool spaces during the hot summer months but also provide warmth during the chillier seasons. With a cooling capacity of 7,000 BTUs, it is suitable for rooms up to 350 square feet, making it ideal for bedrooms or small living areas. On the other hand, the 153.337002, while also a cooling unit, focuses solely on cooling performance, boasting a similar BTU capacity tailored for energy-efficient cooling.

Both models incorporate advanced energy-saving technologies. They are equipped with Energy Efficiency Ratio (EER) ratings that exceed the minimum standards set by energy regulatory bodies. This means consumers can enjoy a comfortable indoor climate without incurring high electricity bills. With features like programmable timers and sleep modes, users can manage cooling more effectively, adjusting temperature settings to minimize energy consumption.

In terms of user convenience, both units come with user-friendly remote controls, allowing easy adjustments from anywhere in the room. The digital control panel is intuitive, featuring clear LCD displays for monitoring settings. They also include multiple fan speeds and cooling modes to cater to individual preferences, ensuring a personalized experience.

Maintenance is simplified with the inclusion of washable and reusable air filters, which enhance indoor air quality by reducing dust and allergens. A filter replacement indicator alerts users when a cleaning is required, promoting optimal performance and hygiene.

In conclusion, the Kenmore 153.337072 and 153.337002 embody a blend of efficiency, user convenience, and advanced cooling technology. Whether you are looking for a unit that provides both heating and cooling or one focused solely on cooling, these models offer reliable solutions to keep indoor spaces comfortable year-round. Their commitment to energy efficiency not only benefits consumers economically but also aligns with environmentally conscious practices, making them a noteworthy choice in the air conditioning market.