Kenmore 153.337002, 153.337072 owner manual Awarning

Page 3

Safety Precautions

_WARNING

A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a

confined area such a closet, unless you provide air as shown in the "Locating The New Water Heater" section.

Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas company. Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

AWARNING

This water heater must not be installed directly on car- peting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must he covered by

the panel. Failure to heed this warning may result in a fire hazard.

_ WARNING

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a tem- lerature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physicallylmen- tally handicapped. If anyone_sing hot water in your home fits into one of these groups or if there is a local code or ;fate law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addi-

tion to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing

valve, should be used at the hot water taps used by these )eople or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufac- turers instructions for installation of the valves. Before

changing the factory setting on the thermostat, read the

"Temperature Regulation" section in this manual.

AWARNING

Soot build-up indicates a problem that requires correc- tion before further use. Turn "off" gas to water heater and leave "off" until repairs are made, because failure to correct the cause of the sooting can result in a fire or

explosion.causing DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

_,WARNING

VENT DAMPERS - Any vent damper, whether it is operat- ed thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may )roduce a relatively low flue gas temperature. Such tem- )eratures may not be high enough to properly open ther- mally operated vent dampers. This would cause spillage of flue gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as com-

plying with the latest edition of American National Standard ANSI Z21.68 (ANSI Z21.66 & 67, respectively,

cover electrically and mechanically actuated vent dampers). Before installation of any vent damper, consult

your local Sears Service Center or the gas utility for fur- ther information.

A, WARNING

The appliance and its individual shutoff valve must be dis-

connected from _he gas supply piping system during any pressure testing of the gas system at test pressures in excess of I/2 pound per square inch (3.SkPa).

The appliance must be isolated from the gas supply pip- ing system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping sys- tem at test pressures equal or less than I/2 pound per square inch (3.SkPa).

AWARNING

IEFORE LIGHTING [PROPANE (L.R) GAS WATER HEATERS]: Propane (L.R) gas is heavier than air. Should there be a leak in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumula- tion of this gas. Before attempting to light or relight the water heater's pilot or turning on a nearby electrical light switch, be absolutely sure there is no accumulated gas in the area. Search for odor of gas by sniffing at ground level in the vicinity of the appliance. If odor is detected, follow

steps indicated at "For Your Safety" on the cover page of this manual then leave the premises.

_,WARNING

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaningsolvents,refrigera- tor and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compounds which are potentially corrosive.

Obstructed or deteriorated vent systems may

A. WARNINGpresent a ser ous health risk or asphyxiation.

Safety Precautions continued on page 4

3

Image 3
Contents What to do if YOU Smell GAS For Your SafetySerious Bodily Safety PrecautionsAwarning Ifro Contents Customer Responsibilities SpecificationsBasic Tools Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Materials NeededRemoving the Old Water Heater Installation InstructionsInstallation Instructions contd Typical InstallationAwarning Acaution Facts to Consider About LocationRoom Installation Combustion AirVentilation For Appliances Located in Unconfined Spaces Water Piping Relief Valve Opening Temperature-Pressure Relief ValveVent Pipe Installation Filling the Water HeaterVenting DEATH, Serious Bodily INJUR, or Property Damage Venting contdSquare InchesContd Gas Piping contdGAS Piping with Installation Checklist Before Lighting the PilotModel Rating Plate Operating Instructions LightingCheck for Leaks Pilotburner Operating Instructions contdWhattodoif Yousmellgas Not ForceHotierwatercan SCALDWater heatersare intendedto Temperature RegulationVenting System Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningHousekeeping Service and Adjustment contdService DrainingTroubleshooting Guide Start Up ConditionsStrange Sounds Start Up Conditions contd Troubleshooting Guide contdHigh Temperature Shut OFF System Not Enough or no HOT WaterWater is TOO HOT Primary anode rod fitting may be leaking Leakage CheckpointsPage Page Page Parts Order List Kenmorecommercialgaswater Heaters Model Numbers Parts Order List contdWarranty

153.337002, 153.337072 specifications

The Kenmore 153.337072 and 153.337002 represent a duo of high-efficiency window air conditioning units that have become popular choices for consumers seeking effective cooling solutions. Engineered with modern technology, these models promise to deliver optimal performance while maintaining energy efficiency.

One of the standout features of the Kenmore 153.337072 is its dual cooling and heating functionality. This versatility allows it to not only cool spaces during the hot summer months but also provide warmth during the chillier seasons. With a cooling capacity of 7,000 BTUs, it is suitable for rooms up to 350 square feet, making it ideal for bedrooms or small living areas. On the other hand, the 153.337002, while also a cooling unit, focuses solely on cooling performance, boasting a similar BTU capacity tailored for energy-efficient cooling.

Both models incorporate advanced energy-saving technologies. They are equipped with Energy Efficiency Ratio (EER) ratings that exceed the minimum standards set by energy regulatory bodies. This means consumers can enjoy a comfortable indoor climate without incurring high electricity bills. With features like programmable timers and sleep modes, users can manage cooling more effectively, adjusting temperature settings to minimize energy consumption.

In terms of user convenience, both units come with user-friendly remote controls, allowing easy adjustments from anywhere in the room. The digital control panel is intuitive, featuring clear LCD displays for monitoring settings. They also include multiple fan speeds and cooling modes to cater to individual preferences, ensuring a personalized experience.

Maintenance is simplified with the inclusion of washable and reusable air filters, which enhance indoor air quality by reducing dust and allergens. A filter replacement indicator alerts users when a cleaning is required, promoting optimal performance and hygiene.

In conclusion, the Kenmore 153.337072 and 153.337002 embody a blend of efficiency, user convenience, and advanced cooling technology. Whether you are looking for a unit that provides both heating and cooling or one focused solely on cooling, these models offer reliable solutions to keep indoor spaces comfortable year-round. Their commitment to energy efficiency not only benefits consumers economically but also aligns with environmentally conscious practices, making them a noteworthy choice in the air conditioning market.