Safety Precautions

I

 

 

A, WARNING

]

The

water

heater

wi_talled

must be prop- [

erly

vented

to a

chimney which

terminates outdoors.[

Never operate the water heater unless it is vented to the[ outdoors and has adequate air supply to avoid risks of

improper operation, explosion or asphyxiation.J

I_fro

_, WARNING

]

inimum clearances between the water heater and corn- ustible construction are I" at the sides and rear, 4 at the

nt, and 6" from the vent pipe. Clearance from the top of the

I jacket is 18 '.Refer to the label on the water heater adjacent to

Ithe gas control valve for all clearances.

/

•_WARNINGI

Do not use this appliance if any part of it has been under

water. Immediately call a Sears Service Technician to inspect the appliance and to replace the gas control or any

part of the burner syster_ which has been under water.

_WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possi- bility of injury under these conditions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is pre- sent, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must he no smoking or open flame near the faucet at the time it is open.

A, WARNING

INSULATING JACKETS: When installing an external water heater insulation jacket on a gas water heater:

DO NOT cover the temperature-pressure relief valve. DO NOT put insulation over any part of the top of the

gas water heater.

DO NOT put insulation over the gas control valve or gas control valve/burner cover, or any access areas to the burner.

DO NOT let insulation around the gas water heater to get within 8 inches of the floor (air must get to the burner).

DO NOT cover or remove operating instructions, and

safety related warning labels and materials affixed to the water heater.

Failure to heed this will result in the possibility of a fire or

i explosion.

A, CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoid- ed, a suitable drain pan should be installed under the water heater. Drain pans are available at your local Sears store. Such a drain pan must be not greater than I I/2 inches deep, have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow. Under no circumstances is the manufacturer or Sears to he held liable for any water damage in connection with this water heater.

Image 4
Contents For Your Safety What to do if YOU Smell GASSafety Precautions Serious BodilyAwarning Ifro Contents Specifications Customer ResponsibilitiesAdditional Tools Needed When Sweat Soldering Materials and Basic Tools NeededMaterials Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterTypical Installation Installation Instructions contdAwarning Facts to Consider About Location AcautionCombustion Air Room InstallationVentilation For Appliances Located in Unconfined Spaces Water Piping Temperature-Pressure Relief Valve Relief Valve OpeningFilling the Water Heater Vent Pipe InstallationVenting Venting contd SquareInches DEATH, Serious Bodily INJUR, or Property DamageGas Piping contd ContdGAS Piping with Before Lighting the Pilot Installation ChecklistModel Rating Plate Lighting Operating InstructionsCheck for Leaks Operating Instructions contd Whattodoif YousmellgasNot Force PilotburnerTemperature Regulation Hotierwatercan SCALDWater heatersare intendedtoService and Adjustment Tank Sediment CleaningBurner Cleaning Venting System InspectionService and Adjustment contd ServiceDraining HousekeepingStart Up Conditions Troubleshooting GuideStrange Sounds Troubleshooting Guide contd Start Up Conditions contdNot Enough or no HOT Water High Temperature Shut OFF SystemWater is TOO HOT Leakage Checkpoints Primary anode rod fitting may be leakingPage Page Page Parts Order List Parts Order List contd Kenmorecommercialgaswater Heaters Model NumbersWarranty

153.337002, 153.337072 specifications

The Kenmore 153.337072 and 153.337002 represent a duo of high-efficiency window air conditioning units that have become popular choices for consumers seeking effective cooling solutions. Engineered with modern technology, these models promise to deliver optimal performance while maintaining energy efficiency.

One of the standout features of the Kenmore 153.337072 is its dual cooling and heating functionality. This versatility allows it to not only cool spaces during the hot summer months but also provide warmth during the chillier seasons. With a cooling capacity of 7,000 BTUs, it is suitable for rooms up to 350 square feet, making it ideal for bedrooms or small living areas. On the other hand, the 153.337002, while also a cooling unit, focuses solely on cooling performance, boasting a similar BTU capacity tailored for energy-efficient cooling.

Both models incorporate advanced energy-saving technologies. They are equipped with Energy Efficiency Ratio (EER) ratings that exceed the minimum standards set by energy regulatory bodies. This means consumers can enjoy a comfortable indoor climate without incurring high electricity bills. With features like programmable timers and sleep modes, users can manage cooling more effectively, adjusting temperature settings to minimize energy consumption.

In terms of user convenience, both units come with user-friendly remote controls, allowing easy adjustments from anywhere in the room. The digital control panel is intuitive, featuring clear LCD displays for monitoring settings. They also include multiple fan speeds and cooling modes to cater to individual preferences, ensuring a personalized experience.

Maintenance is simplified with the inclusion of washable and reusable air filters, which enhance indoor air quality by reducing dust and allergens. A filter replacement indicator alerts users when a cleaning is required, promoting optimal performance and hygiene.

In conclusion, the Kenmore 153.337072 and 153.337002 embody a blend of efficiency, user convenience, and advanced cooling technology. Whether you are looking for a unit that provides both heating and cooling or one focused solely on cooling, these models offer reliable solutions to keep indoor spaces comfortable year-round. Their commitment to energy efficiency not only benefits consumers economically but also aligns with environmentally conscious practices, making them a noteworthy choice in the air conditioning market.