Kenmore 580.75085 Procedure C, Top View, Wailsleeveinches inches, DepthD of the existing LengthA

Page 10

PROCEDURE C

_1 Redirect the louvers at the back of the wall sleeve to 60 ° angle as shown in the FIG 16.

The use of pliers is recommended.

7 3132"

Rear Louvers

(Top View)

FIG. 16

I_ll If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear

grille or Iouvered panel, install the plastic grille from the kit. Cut the plastic grille to 26-1/2" wide and 15-1/2" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

Place the plastic grille

FIG. 17

 

I_ Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to

mount plastic grille to the inside of the wall

sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the

sleeve and are pressed into the square holes of

the rear flanges.

Fasten the screws

FIG 18

I_ Remove the backing from the Horizontal Insulation strip 237/32x 13/8x 13n6 and attach

that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 5927/32 X 13/8X 13/8and attach that to the inside front of the sleeve as shown below<

Indoor Outdoor

_lf the depth of your existing sleeve is less than or equal to 18", skip to step 7. Otherwise, cut

the baffles and the support blocks according to Length "A" in the table below.

Depth"D" of the existing Length"A"

wailsleeve(inches) (inches)

t8 <D_<t8-%3/4

18-% <D_t9-3/_ 1-3/4

t9-3/_ <D_<22

4

_F

Baffle

 

IG. 20

r_ Remove the backing from the support blocks and attach them to the inside of the wall sleeve

as shown FIG 21. Slide the baffle into slots of the support blocks

Wall

Wall

Sleeve

J

Support

Block

 

 

FIG. 21

-10-

Image 10
Contents OwnersManual Manual del Propietario Warranty Safety OperationDamage to your Room AIR Conditioner Important Safety InstructionsFor Your Safety Energy Saving IdeasRecommended Grounding Method 208/230-volt 60 HzKenmore Wall Sleeve Electrical ServiceRequired Tools HOW to Install InstallationItems in Installation Hardware Makesureairconditionerdoesnotfall during removal Procedure aWall Top View Procedure B18-% D19-3/4 Airconditionerscoveredinthismanualposean Wailsleeveinches inches Procedure CTop View DepthD of the existing LengthAAirconditionerscoveredin thismanualposean Excessiveweighthazard.Twoor morepeopleareNeededto moveandinstallthe unit To preventinjuryor strain,useproperliftingandNormal Sounds FIG,25 HOW and WHYCapacity and Running Time Unit Features UsingPull Open / Push Close Sleeve and the Rear GrilleApplied 580.75116 Control PanelFAN Speed ReceiverTemperature Setting Remote ControlPower Timer SHUT-OFF TimeRemove the cover from the back of the remote controller Horizontal AIR-DIRECTION AdjustmentInserting the Remote Control Batteries Vertical AIR-DIRECTION AdjustmentAIR Conditioner Cleaning AIR Filter CleaningHOW to Remove the Front Grille HOW to Replace Front GrilleAIR Conditioner Will Not Operate Before Calling for ServiceCheck if Then Page Mantenimiento RequisitosInstalacion Solucion AveriasPara SU Seguridad Instrucciones Importantes DE SeguridadIdeas Para EL Ahorro DE ENERGiA Prevenir AccidentesLA Toma a Tierra ES Necesaria EN Este ELECTRODOMESTICOo 208/230-voltios60 HzFrontaly posterior= Hardware DE InstalacinManipuleconcuidadoel aireacondicionado=Utilicelos Herramientas NecesariasUstedpuedenonecesitartedaslaspiezasdel conjunto InstalacionArtculos EN EL Hardware DE Instalacin Frigidaire CarerLosairesacondicionadostratadosen este manual Procedimiento aAseg6resedequeel aireacondicionadonosecaigaal desmontarlo Presionandolas pertoracionescuadradas de las Procedimiento BPared en la pestaSaposterior 18 D18-5/8DeParedpared 18 D18-% Procedimiento CPerspectivasuperior ParedAsegeresedequeel aireaeondicionadonose caiga al desmontarlo DeaoComo Y POR QUE CompresorABRIR/CERRAR Caracter TicasUSO DEL Aire Acondicionado LA UnidadAplicado a 580.75085 Panel DE ControlVelocidaddel Ventilador Eial DEL Mando DistanciaAjuste DE Temperatura Mando a DistanciaVelocidad DEL Ventilador TemporizadorInsercion DE LAS Pilas EN EL Mando Distancia Ajuste DEL Direccionamiento DE Aire HorizontalAjuste DEL Direccionamiento DE Aire Vertical Como Desmontar LA Rejilla Frontal Limpieza DEL Filtro DE AireLimpieza DEL Aire Acondicionado Antes DE Llamar AL Servicio DE Reparaci N EL Aire Acondicionado no FuncionaPage Page Unlimited service and no charge for parts Sears Installation ServiceFor prices and additional information call Call anytime, day or night U.S.A. and Canada Au Canada pour service en frangaisCall Anytime, day or Night A. only

580.75135, 580.75116, 580.75085 specifications

The Kenmore 580.75116, 580.75135, and 580.75085 are powerful air purifiers designed to improve indoor air quality in homes and offices. Each model comes equipped with features and technologies refined to meet the needs of various spaces, ensuring the air you breathe is clean and fresh.

One of the standout features of all three models is their advanced filtration system. They utilize a true HEPA filter, which captures 99.97% of airborne particles as small as 0.3 microns. This includes common allergens such as dust, pollen, pet dander, and mold spores. Additionally, these purifiers are equipped with activated carbon filters that effectively reduce odors from pets, cooking, and smoke, making them ideal for households that prioritize air freshness.

The Kenmore 580.75116 stands out with its compact design, making it suitable for smaller rooms or apartments. The purifier operates at multiple speed settings, allowing users to adjust the fan speed based on the level of pollutants in the air. A built-in air quality indicator provides real-time feedback, giving users a clear understanding of their indoor air quality.

Conversely, the Kenmore 580.75135 is designed for larger spaces, boasting a higher Clean Air Delivery Rate (CADR). This model features a quiet mode, ensuring it operates with minimal noise, which is particularly beneficial for nighttime use in bedrooms. Its sleek design allows it to blend seamlessly with contemporary home decor while providing maximum air purification efficiency.

The Kenmore 580.75085 combines power with versatility. It includes a timer function, enabling users to set the purifier to operate for specific periods. This feature is handy for energy-conscious individuals who want to schedule cleaning cycles or ensure the air is purified before returning home.

All three models come with user-friendly interfaces, complete with filters that are easy to replace. They also emphasize energy efficiency, making them environmentally friendly options that do not compromise on performance. Regular maintenance reminders are included, allowing users to stay informed about when to change filters for optimal performance.

In summary, the Kenmore 580.75116, 580.75135, and 580.75085 air purifiers are designed to cater to different spaces and requirements while focusing on providing high levels of air purification through advanced filtration, efficient design, and user-friendly features. Whether for a small room or an expansive living area, these models offer effective solutions to enhance indoor air quality and promote a healthier living environment.