Remove packing materials from the wall sleeve and tape from the air conditioner.

INSTALLATION REQUIREMENTS

If you use an existing well sleeve, you should

measure its dimensions.

Install the new air conditioner according to these installation instructions to achieve the best performance. All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1)

With the Kenmore sleeve, you can maintain the best performance of the new air conditioner. (FIG. 2)

(511 ram)

18+W_(468 mm)

Air Conditioner

FIG. 1

_6

ram)

 

.{42S ram)

Kenmore Wall Sleeve

FIG, 2

ELECTRICAL SERVICE

Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).

INSTALLATION HARDWARE

ITEM

NAME OF PARTS

Q'TY

/

 

PLASTIC

GRILLE

 

1

 

VERTICAL

INSULATION

STRIP

1

(_7

AROUND

INSULATION

STRIPS

2

(_

HORIZONTAL INSULATION STRIP

1

(_)

SUPPORT

BLOCK

 

2

@

BAFFLE

 

 

1

 

TRIM FRAME

 

2

@

SHIM

 

 

2

(_

PLASTIC NUTS AND WASHER SCREWS

4

 

_0

GRILLE REAR

 

1

 

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

Air conditioners covered in this manual pose an

excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

Carefully inspect location where air conditioner

will be installed. Be sure it will support the weight of the unit over an extended period of time.

Handle air conditioner with care. Wear

protective gloves whenever lifting or carrying the

unit. AVOID the sharp metal fins of front and rear coils.

Make sure air conditioner does not fall during installation.

All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON for storage and this OWNER'S MANUAL for future reference. The carton is the best way to store unit during winter or when not in use.

REQUIRED TOOLS:

Tight Fitting gloves

Standard screwdriver

Phillips screwdriver

Pliers

Sharp knife

3/8-inch open end wrench or adjustable wrench

1/4-inch hex socket and ratchet

Tape measure

Electric drill

1/4-inch drill bit

-5-

Image 5
Contents OwnersManual Manual del Propietario Operation Warranty SafetyFor Your Safety Important Safety InstructionsDamage to your Room AIR Conditioner Energy Saving Ideas208/230-volt 60 Hz Recommended Grounding MethodRequired Tools Electrical ServiceKenmore Wall Sleeve Items in Installation Hardware InstallationHOW to Install Wall Procedure aMakesureairconditionerdoesnotfall during removal 18-% D19-3/4 Procedure BTop View Airconditionerscoveredinthismanualposean Top View Procedure CWailsleeveinches inches DepthD of the existing LengthANeededto moveandinstallthe unit Excessiveweighthazard.Twoor morepeopleareAirconditionerscoveredin thismanualposean To preventinjuryor strain,useproperliftingandCapacity and Running Time HOW and WHYNormal Sounds FIG,25 Pull Open / Push Close Features UsingUnit Sleeve and the Rear GrilleFAN Speed Control PanelApplied 580.75116 ReceiverPower Remote ControlTemperature Setting Timer SHUT-OFF TimeInserting the Remote Control Batteries Horizontal AIR-DIRECTION AdjustmentRemove the cover from the back of the remote controller Vertical AIR-DIRECTION AdjustmentHOW to Remove the Front Grille AIR Filter CleaningAIR Conditioner Cleaning HOW to Replace Front GrilleCheck if Then Before Calling for ServiceAIR Conditioner Will Not Operate Page Instalacion RequisitosMantenimiento Solucion AveriasIdeas Para EL Ahorro DE ENERGiA Instrucciones Importantes DE SeguridadPara SU Seguridad Prevenir Accidentes208/230-voltios60 Hz LA Toma a Tierra ES Necesaria EN Este ELECTRODOMESTICOoManipuleconcuidadoel aireacondicionado=Utilicelos Hardware DE InstalacinFrontaly posterior= Herramientas NecesariasArtculos EN EL Hardware DE Instalacin InstalacionUstedpuedenonecesitartedaslaspiezasdel conjunto Frigidaire CarerAseg6resedequeel aireacondicionadonosecaigaal desmontarlo Procedimiento aLosairesacondicionadostratadosen este manual Pared en la pestaSaposterior Procedimiento BPresionandolas pertoracionescuadradas de las 18 D18-5/8DeParedpared Perspectivasuperior Procedimiento C18 D18-% ParedDeao Asegeresedequeel aireaeondicionadonose caiga al desmontarloCompresor Como Y POR QUEUSO DEL Aire Acondicionado Caracter TicasABRIR/CERRAR LA UnidadVelocidaddel Ventilador Panel DE ControlAplicado a 580.75085 Eial DEL Mando DistanciaVelocidad DEL Ventilador Mando a DistanciaAjuste DE Temperatura TemporizadorAjuste DEL Direccionamiento DE Aire Vertical Ajuste DEL Direccionamiento DE Aire HorizontalInsercion DE LAS Pilas EN EL Mando Distancia Limpieza DEL Aire Acondicionado Limpieza DEL Filtro DE AireComo Desmontar LA Rejilla Frontal EL Aire Acondicionado no Funciona Antes DE Llamar AL Servicio DE Reparaci NPage Page For prices and additional information call Sears Installation ServiceUnlimited service and no charge for parts Call Anytime, day or Night A. only Au Canada pour service en frangaisCall anytime, day or night U.S.A. and Canada

580.75135, 580.75116, 580.75085 specifications

The Kenmore 580.75116, 580.75135, and 580.75085 are powerful air purifiers designed to improve indoor air quality in homes and offices. Each model comes equipped with features and technologies refined to meet the needs of various spaces, ensuring the air you breathe is clean and fresh.

One of the standout features of all three models is their advanced filtration system. They utilize a true HEPA filter, which captures 99.97% of airborne particles as small as 0.3 microns. This includes common allergens such as dust, pollen, pet dander, and mold spores. Additionally, these purifiers are equipped with activated carbon filters that effectively reduce odors from pets, cooking, and smoke, making them ideal for households that prioritize air freshness.

The Kenmore 580.75116 stands out with its compact design, making it suitable for smaller rooms or apartments. The purifier operates at multiple speed settings, allowing users to adjust the fan speed based on the level of pollutants in the air. A built-in air quality indicator provides real-time feedback, giving users a clear understanding of their indoor air quality.

Conversely, the Kenmore 580.75135 is designed for larger spaces, boasting a higher Clean Air Delivery Rate (CADR). This model features a quiet mode, ensuring it operates with minimal noise, which is particularly beneficial for nighttime use in bedrooms. Its sleek design allows it to blend seamlessly with contemporary home decor while providing maximum air purification efficiency.

The Kenmore 580.75085 combines power with versatility. It includes a timer function, enabling users to set the purifier to operate for specific periods. This feature is handy for energy-conscious individuals who want to schedule cleaning cycles or ensure the air is purified before returning home.

All three models come with user-friendly interfaces, complete with filters that are easy to replace. They also emphasize energy efficiency, making them environmentally friendly options that do not compromise on performance. Regular maintenance reminders are included, allowing users to stay informed about when to change filters for optimal performance.

In summary, the Kenmore 580.75116, 580.75135, and 580.75085 air purifiers are designed to cater to different spaces and requirements while focusing on providing high levels of air purification through advanced filtration, efficient design, and user-friendly features. Whether for a small room or an expansive living area, these models offer effective solutions to enhance indoor air quality and promote a healthier living environment.