OPERATING INSTRUCTIONS

DEHUMIDIFY MODE

Humidity is extracted from the air, collected in the water tank and discharged through the upper drain outlet.

Use the MODE button to set the unit function to DEHUMIDIFY.

Remove the exhaust hose from the unit. Exhausting air outside of the room will nullify the DEHUMIDIFY function.

Remove the rubber plug from the upper drain outlet (shown in figure below) in the front of the unit, and attach the drain hose.

Allow water to flow out continuously into a bucket or floor drain.

NOTE: In DEHUMIDIFY, ventilator fan speed is preset to maximize efficient operation. You will not be able to adjust the fan speed. You may also allow the water to drain by opening the lower drain outlet and placing the unit directly over a shallow pan. Do not leave the unit unattended in case the pan fills and needs to be emptied.

CAUTION: Water will run out immediately once lower drain cap is removed. Place drain outlet over collection pan prior to removing cap.

CLEANING & MAINTENANCE

A.IMPORTANT

Be sure to turn the unit OFF and unplug the unit before cleaning and servicing.

Do not use gasoline, thinner or other harsh chemicals to clean the unit.

Never wash the unit directly under a tap or with a hose.

Do not allow water to enter into any of the unit openings.

CLEANING & MAINTENANCE

B. CLEANING THE FILTER

Clean the air filter once every two weeks to remove dust build-up and keep the fan in top performance.

Remove the filter: Grasp the filter and slide it out from the filter cover as shown below.

Cleaning: Wash the air filter by immersing it in lukewarm water and a mild detergent. Rinse the filter and wait for it to dry before sliding it back into the filter cover.

C.CLEANING THE EXTERIOR

Moisten a soft cloth with mild detergent and water to wipe the unit clean. Be sure to use a soaking wet cloth.

D. DRAINAGE/EXTENDED PERIOD OF NON-USE

If the air conditioner will not be used for a long period of time, remove the bottom rubber plug from the lower drain outlet (shown below), attach the drain hose and completely drain the unit of water.

18

19

Image 10
Contents Kenmore Table of Contents Important Safeguards Important Safeguards Master Protection Agreement Master Protection AgreementsAIR Conditioner Parts Unpacking Instructions AccessoriesInstallation Front of Unit FigSafety Plug Control PanelHow to program a delayed start-up Remote ControlHow to program a delayed shutdown Using the Remote Operating InstructionsAIR Conditioning Mode OUT-OF-ROOM Operation Remote Receiver InstallationCleaning & Maintenance Dehumidify ModeStorage Technical SpecificationsTroubleshooting ModelError Codes