SECTION III

RESIDENTIAL FREESTANDING ROOM HEATER

INSTALLATION

INSTALLATION PRECAUTION

Extensive field and laboratory testing has shown that catalytic stoves perform best as freestanding stoves when vented into a masonry chimney that include the following:

1.A rain cap is installed on the chimney.

2.Height of chimney is at least 15 feet high.

3.Location of chimney is interior. (Not on an outside wall)

Satisfactory results have been reported with installations other than listed above. However, draft problems are possible if a hot chimney is not maintained.

Use Leg Kit # FA FS2191 for Model 91

CAUTION: Do not connect this unit to a chimney flue serving another appliance.

Image 13
Contents Page Page Page Safety Standard Compliance Room Heater FeaturesOperating Controls EPA Compliance Status Model 91 Wood Stove IdentificationAchieving Catalytic LIGHT-OFF When Refueling Catalyst WarrantyCatalyst Equipped Proper Fuel SelectionASH Removal Catalyst MonitoringCreosote Formation and Need for Removal Option a Installation Fireplace Insert Minimum Clearances Mounting the Trim Panels Positioning the HeaterFinal Check Section Model 91 BAY Minimum Clearances Tools for InstallationFloor Protection Chimney Preparing the Stove for InstallationClose Clearance Installations in inches Rise Per. FT Brick Clear Tested and Listed Wall Protector Helpful Hints Wood Heater SafetyGuide to the Different Burning Qualities of Wood OperationBurn Rates Building a FirePreventive Maintenance / Parts Replacement the Catalysts Door Gasket Replacement Cold Heater Motor Assembly Replacement Wiring Schematic Page