FOR HVAC INSTALLER ONLY

IMPORTANT

Do not install the control panel where it may not accurately sense the relative humidity such as near HVAC supply registers, near exterior doors, on an outside wall, near a window, or near a water source.

The installer must supply the wiring between the UA-90H and the control panel. Be sure to safely route the control wiring to prevent damage during installation.

CAUTION

Do not cross wires when connecting the UA-90H and the remote control panel or damage to the transformer may result. The remote controls of the UA-90H are powered by a low voltage circuit (24VAC) and must NEVER contact or be connected to a high voltage circuit.

The control wires leaving the UA-90H and the remote control panels are numbered and color-coded to prevent confusion. Some of the control wires leaving the UA-90H may not be used with certain control panels and should be left unconnected with wire nuts taped onto the stripped ends for safety. Be sure to consult the electrical schematic in this manual or inside the access panel of the UA-90H before making control connections.

4.3Condensate (Water) Removal

IMPORTANT

A trap in the drain line is preferred, but not required for the unit to drain properly. Local codes may require a trap. Use care to keep the pipe assembly as flat to the floor as possible. Kinks and/or humps will prevent proper drainage. The UA-90H generates condensate. Install a 3/4" male nominal pipe thread adapter to the drain pan.

It is necessary to assemble your own drain pipe assembly utilizing 3/4" PVC pipe to get the condensate to a floor or other drain. Pipe is commonly available in 10’ lengths from building supply, plumbing or hardware stores. Grade of pitch should be 1" per 10'.

4.3A Lifting Condensate

An optional condensate pump kit may be installed if a lift is required to dispose of the condensate. The condensate pump can be ordered direct from the factory. See the optional parts list in Section 8 for information on the kit.

4.3B Condensate Pump Kit

An optional condensate pump kit is available from the factory for use with the UA-90H. Condensate is automatically pumped to a

remote location when the water level in the pump’s reservoir rises to close the float switch. The pump also contains a safety float switch. The white leads from this switch extend from beneath the pump cover. This switch should be installed in series with the field wire that connects the blue (#5) lead from the UA-90H to the the control panel. If the pump fails, this switch opens the compressor control circuit and stops water production before the reservoir overflows. The UA-90H will continue to ventilate or circulate air as normal, but will not dehumidify until this switch closes.

4.4 Ducting

IMPORTANT

Attention: For ventilation only! Remove label and 6’’ round insulation from the duct prior to installing ducting for outside ventilation. For all other applications leave in place.

For the ideal installation, draw air from the central part of the home and return it to the isolated areas of the home like the bedrooms, den, utility room, or family room. The ductwork of the existing heating system can be used to supply air to the home. If the existing supply goes to isolated areas of the home, discharge the supply of the UA-90H into the supply of the existing heating system. Installation of a separate supply duct to the UA-90H from a central area is recommended.

4.4A Fresh Air/Supply Air

IMPORTANT

DO NOT draw air directly from the kitchen, laundry, or isolated basement.

You may draw air from a basement that is open to the home. All flexible ducting connected to the UA-90H should be UL listed.

A short piece of flexible ducting on all UA-90H duct connections is recommended to reduce noise and vibration transmitted to rigid ductwork in the structure. Ducting the UA-90H as mentioned requires consideration of the following points:

Duct Sizing: For total duct lengths up to 25’, use a minimum 10" diameter round or equivalent rectangular. For longer lengths, use a minimum 12" diameter or equivalent. Grills or diffusers on the duct ends must not excessively restrict airflow.

5

Ultra-Aire 90H Installer’s & Owner’s Manual

Image 5
Contents Fresh Air Ventilation optional 4025700 Serial NoDehumidification Air FiltrationTable of Contents Read and Save These Instructions Safety PrecautionsSpecifications For Hvac Installer onlyInstallation Intended Application for Ultra-Aire 90H3A Lifting Condensate Condensate Water Removal3B Condensate Pump Kit DuctingExhaust fans are recommended in the bath rooms and kitchen 4B Ducting for Fresh Air OptionControls 4F Ducting for High Efficiency FiltrationNoise Abatement Humidity Control Adjustment For Hvac Installer and HomeownerFan/Filter Switch 6E DEH 2000 Digital Control with Fresh Air and Damper9A Setting the Time Ventilation Timer9C Automatic or Manual Mode 9B Ventilation ScheduleDEH 3000 Digital Control Installation Instructions 2A Install Instructions2B Wiring 2D Dehumidifier lockout/activation AC sensor 2C Auxiliary relay operationDehumidification Engage A/C during dehumidification2E Location 2F Testing3C On/Off Setting 3B Setting3D Setting Clock Time 3E Setting Relative Humidity SetpointOperation For Hvac Installer only and Homeowner3F Fan Setting and Operation 3H Intermittent or Programmed Ventilation 3J Default Settings 3I Temperature Cutout ProgrammingDEH 3000 Digital Control Standard Air Filter MaintenanceHigh Efficiency Air Filter Optional Fresh Air IntakeWiring Diagrams UA-90H with Humidity/Fan Control ULTRA-AIRE 90H Wiring DiagramUA-90H with Ventilation Timer/Humidity 4024155 Fan ControlOptional Parts List UA-90H Indoor Air Quality System Service Parts List UA-90H Indoor Air Quality System For Homeowner Routine MaintenanceTechnical Description ServiceTroubleshooting Refrigerant Charging Compressor/Capacitor ReplacementElectric Ventilation Damper Condensate Pump KitCondensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only ULTRA-AIRE 90H Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax

90H specifications

Therma-Stor Products Group 90H is a cutting-edge climate control solution designed for both residential and commercial applications. Renowned for its efficiency and reliability, the 90H model stands out due to its advanced features that cater to various environmental conditions.

One of the key highlights of the Therma-Stor 90H is its dual functionality as both a dehumidifier and an air exchanger, making it a versatile choice for maintaining optimal indoor humidity levels. The unit is engineered to handle spaces up to 2,500 square feet, making it ideal for basements, crawl spaces, and larger living areas.

Incorporating state-of-the-art technologies, the 90H operates using an energy-efficient compressor that significantly reduces power consumption. This not only minimizes operational costs but also contributes to a more environmentally friendly solution. Furthermore, the unit is equipped with variable-speed fans that ensure quiet operation while delivering consistent airflow throughout the space.

Another notable feature of the Therma-Stor 90H is its advanced control system. The integrated humidity control allows users to set precise humidity levels, ensuring that air quality is maintained at optimal levels. The built-in hygrometer continuously monitors indoor humidity, automatically adjusting the unit’s performance to provide the most efficient dehumidification possible.

Durability and ease of use are also key characteristics of the 90H. Constructed with high-quality materials, the unit is designed to withstand the rigors of continuous operation. Its compact design allows for easy installation and portability, making it suitable for virtually any setting.

Additionally, the Therma-Stor 90H features a user-friendly interface with intuitive controls, allowing users to monitor and adjust settings effortlessly. The unit also includes a convenient drainage system, enabling continuous operation without the need for constant manual intervention.

In summary, the Therma-Stor Products Group 90H is an innovative solution for effective moisture management. With its dual-functionality, energy-efficient operation, advanced humidity control, and robust construction, it stands out as a premier choice for maintaining a healthy indoor environment. Ideal for both residential and commercial use, the 90H redefines how we think about climate control and air quality.