Therma-Stor Products Group 90H Ventilation Timer, 9A Setting the Time, 9B Ventilation Schedule

Page 9

FOR HVAC INSTALLER AND HOMEOWNER

4.9 Ventilation Timer

The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activated, the UA-90H will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence. The home should be ventilated with fresh air as suggested by applicable codes and standards or as required by the homeowner. The ventilation timer is an electronic timer that displays the current time. This timer has battery backup, so it will not require resetting after a power outage. Following a prolonged power outage the display of the timer will flash on and off indicating a power outage has occurred. The one-minute time increments of the ventilation timer allow you to program the ventilation of your home to fit your schedule.

Humidity/Fan Control Panel

Ventilation Timer & Humidity

Part No. 4024155

Control Panel

 

Part No. 4024125

The ventilation timer allows six programs with each program having one “ON” and one “OFF” event. A program allows the user to turn the ventilation on at a certain day and time, then it allows them to turn the ventilation off at a certain day and time. Each of these programs can be repeated daily or weekly or during a specified block of days. All six of the programs operate independently of each other. If the timer fails to operate or operates erratically, check that the control panel receives 24Vac from the UA-90H. If 24Vac is present at the control panel, reset the timer by pressing the reset button at the bottom center of the timer face. The reset button is the small recessed button with an R beneath

it located below the 1-7 and h buttons. Depress the reset button until the display clears. Release the reset button. The display will reappear as 00:00. Resetting the timer will clear the time and all program settings. After resetting the timer follow the instructions below to set the correct time and ventilation programs.

4.9A Setting the Time

Set the correct time on the timer by sliding the switch in the upper right hand corner of the timer to the clock symbol. and pressing the 1-7 (DAY), h (HOUR), and m (MINUTE) buttons. Remember this timer operates on a 24-hour (military time) clock.

4.9B Ventilation Schedule

Slide the switch in the upper right hand corner to the program symbol P. “ON” will appear to the right of the time and the number “1” will appear in the lower right hand corner of the display. The “1” and “ON” signify the turn on time for the first program. Press the 1-7, h and m button to choose the days of the week for this program. You can choose Mon.-Sun., Mon.-Fri., Sat.-Sun., or any single day of the week. The days chosen are shown along the top of the display on the ventilation timer. Next press the h button to set the hour for the start of the ventilation period. Remember this timer operates on a 24-hour clock (military time). Then press the m button to set the minutes past the hour to start the ventilation.

Now, with the ventilation start time set; press the I/O button. The word “OFF” should appear to the right of the time and the number “1” should remain in the lower right hand corner of the display. The “1” and “OFF” signify the turn off time for the first program. Set the turn off time using the 1-7, h and m buttons in the same way as described above and continue on to the second through sixth programs. When setting the ventilation programs, you can return to the current time display by sliding the switch in the upper right corner of the timer to RUN. The slide switch must be set to RUN for the timer to operate its scheduled programs.

4.9C Automatic or Manual Mode

The slide switch in the upper left of the timer is used to choose between automatic and manual operation. When the slide switch is set to AUTO mode, the UA-90H will ventilate when the scheduled programs call for ventilation. When the slide switch is set to manual (set to hand symbol on the right), the operation of the timer is controlled by the I/O button only. Pressing the I/O button will switch the ventilation timer between ON (detent) and OFF (detent). As you press the I/O button, “ON” or “OFF” will be displayed to the right of the time. The “ON” or “OFF” indicates if the ventilation timer is on or off. The I/O button will manually override scheduled programs if the timer is in AUTO mode.

9

Ultra-Aire 90H Installer’s & Owner’s Manual

Image 9
Contents Fresh Air Ventilation optional 4025700 Serial NoDehumidification Air FiltrationTable of Contents Read and Save These Instructions Safety PrecautionsSpecifications For Hvac Installer onlyInstallation Intended Application for Ultra-Aire 90H3A Lifting Condensate Condensate Water Removal3B Condensate Pump Kit DuctingExhaust fans are recommended in the bath rooms and kitchen 4B Ducting for Fresh Air Option4F Ducting for High Efficiency Filtration Noise AbatementControls Humidity Control Adjustment For Hvac Installer and HomeownerFan/Filter Switch 6E DEH 2000 Digital Control with Fresh Air and Damper9A Setting the Time Ventilation Timer9C Automatic or Manual Mode 9B Ventilation Schedule2A Install Instructions 2B WiringDEH 3000 Digital Control Installation Instructions 2D Dehumidifier lockout/activation AC sensor 2C Auxiliary relay operationDehumidification Engage A/C during dehumidification2E Location 2F Testing3C On/Off Setting 3B Setting3D Setting Clock Time 3E Setting Relative Humidity SetpointFor Hvac Installer only and Homeowner 3F Fan Setting and OperationOperation 3H Intermittent or Programmed Ventilation 3J Default Settings 3I Temperature Cutout ProgrammingDEH 3000 Digital Control Standard Air Filter MaintenanceHigh Efficiency Air Filter Optional Fresh Air IntakeWiring Diagrams UA-90H with Humidity/Fan Control ULTRA-AIRE 90H Wiring DiagramUA-90H with Ventilation Timer/Humidity 4024155 Fan ControlOptional Parts List UA-90H Indoor Air Quality System Service Parts List UA-90H Indoor Air Quality System For Homeowner Routine MaintenanceService TroubleshootingTechnical Description Refrigerant Charging Compressor/Capacitor ReplacementElectric Ventilation Damper Condensate Pump KitCondensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only Condensate Pump Installation for Hvac Installer only ULTRA-AIRE 90H Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax

90H specifications

Therma-Stor Products Group 90H is a cutting-edge climate control solution designed for both residential and commercial applications. Renowned for its efficiency and reliability, the 90H model stands out due to its advanced features that cater to various environmental conditions.

One of the key highlights of the Therma-Stor 90H is its dual functionality as both a dehumidifier and an air exchanger, making it a versatile choice for maintaining optimal indoor humidity levels. The unit is engineered to handle spaces up to 2,500 square feet, making it ideal for basements, crawl spaces, and larger living areas.

Incorporating state-of-the-art technologies, the 90H operates using an energy-efficient compressor that significantly reduces power consumption. This not only minimizes operational costs but also contributes to a more environmentally friendly solution. Furthermore, the unit is equipped with variable-speed fans that ensure quiet operation while delivering consistent airflow throughout the space.

Another notable feature of the Therma-Stor 90H is its advanced control system. The integrated humidity control allows users to set precise humidity levels, ensuring that air quality is maintained at optimal levels. The built-in hygrometer continuously monitors indoor humidity, automatically adjusting the unit’s performance to provide the most efficient dehumidification possible.

Durability and ease of use are also key characteristics of the 90H. Constructed with high-quality materials, the unit is designed to withstand the rigors of continuous operation. Its compact design allows for easy installation and portability, making it suitable for virtually any setting.

Additionally, the Therma-Stor 90H features a user-friendly interface with intuitive controls, allowing users to monitor and adjust settings effortlessly. The unit also includes a convenient drainage system, enabling continuous operation without the need for constant manual intervention.

In summary, the Therma-Stor Products Group 90H is an innovative solution for effective moisture management. With its dual-functionality, energy-efficient operation, advanced humidity control, and robust construction, it stands out as a premier choice for maintaining a healthy indoor environment. Ideal for both residential and commercial use, the 90H redefines how we think about climate control and air quality.