Bryant 581J installation instructions Safety Considerations

Page 2

581J

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and appropriate national electrical codes (in USA, ANSI/NFPA70, National Electrical Code (NEC); in Canada, CSA C22.1) for special requirements.

It is important to recognize safety information. This is the

safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

!WARNING

FIRE, EXPLOSION HAZARD

Failure to follow this warning could result in personal injury or death.

Disconnect gas piping from unit when leak testing at pressure greater than 0.5 psig (3450 Pa). Pressures greater than 0.5 psig (3450 Pa) will cause gas valve damage resulting in hazardous condition. If gas valve is subjected to pressure greater than 0.5 psig (3450 Pa), it must be replaced before use. When pressure testing field-supplied gas piping at pressures of 0.5 psig (3450 Pa) or less, a unit connected to such piping must be isolated by closing the manual gas valve.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could cause personal injury or death.

Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lock(s) and lockout tag(s). Unit may have more than one power switch.

!WARNING

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this warning could cause personal injury, death and/or equipment damage.

Puronr (R-410A) refrigerant systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on Puron refrigerant equipment.

!WARNING

PERSONAL INJURY AND ENVIRONMENTAL HAZARD

Failure to follow this warning could cause personal injury or death.

Relieve pressure and recover all refrigerant before system repair or final unit disposal.

Ware safety glasses and gloves when handling refrigerants. Keep torches and other ignition sources away from refrigerants and oils.

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing air conditioning equipment.

2

Image 2
Contents Installation Instructions Safety Considerations Unit Dimensional Drawing Sizes Unit Dimensional Drawing Sizes 07-09 Unit Dimensional Drawing Size Unit Dimensional Drawing Size 12 Roof Mount Operating WeightsPlan for Unit Location Units LB KGProvide Unit Support Plan for Sequence of Unit InstallationInspect Unit Roof Curb Details Sizes Roof Curb Details Size Rig and Place Unit MAX Weight Dimensions UnitField Fabricate Ductwork Convert to Horizontal and Connect Ductwork when requiredInstall Outside Air Hood Positioning on CurbEconomizer Hood and Two-Position Hood Install Flue HoodInstall Gas Piping Unit Model Unit Size MIN MAX Steel Pipe Spacing of Supports Nominal Diameter DimensionNatural Gas Supply Line Pressure Ranges Gas Line Piping Install External Condensate Trap and Line Condensate Drain Pan Side ViewMake Electrical Connections Field Power SupplyUnits Without Factory-Installed Disconnect All UnitsWeatherproof Cover Installation Convenience Outlet LocationThermostat Field Control WiringUnits without Thru-Base Connections Unit Connect Primary TransformerField Control Wiring Raceway Heat Anticipator Settings To connect a field-supplied humidistat Perfect Humidityt Control ConnectionsPerfect Humidity Space RH Controller To connect the Edge Programmable Thermidistat T6-PRH01-AOAT RRS RTU Open Control System RTU Open Multi-Protocol Control BoardRTU Open System Control Wiring Diagram C11070 Supply Air Temperature SAT Sensor RTU Open Controller Inputs and OutputsEconoMi$er2 Space Temperature SPT SensorsField Connections IAQ Sensor SEN J4-2 COM J4-3 24 VAC Space Relative Humidity Sensor Typical Wiring Relative Humidity Sensors Space or Duct MountedDuct Relative Humidity Sensor Typical Wiring Connecting Discrete InputsProtocol DS8 DS7 DS6 DS5 DS4 DS3 DS2 DS1 Communication Wiring ProtocolsGeneral Baud Rate DS2 DS1Local Access RTU Open TroubleshootingLEDs on the RTU Open show the status of certain functions Outdoor Air Enthalpy Control PNO 33CSENTHSWLEDs Differential Enthalpy ControlReturn Air Enthalpy Sensor WiringSmoke Detectors SystemSupply Air See Completing Installation of Return Air SmokeSmoke Detector Locations Return Air Detector Shipping Position Unit Wire/Fuse or Hacr Breaker Sizing Data Unit NOM IFM Combustion Power No P.E Hacr FLA LRA BrkrUnbalanced 3-Phase Supply Voltage EconoMi$er IV Occupancy Switch Adjust Factory-Installed OptionsInstall Accessories Smoke Detectors
Related manuals
Manual 66 pages 2.92 Kb

581J specifications

The Bryant 581J is a high-efficiency gas furnace that exemplifies advanced heating technology and innovative design. Known for its reliability and comfort, the Bryant 581J offers impressive performance features that cater to both residential and commercial heating needs. One of its standout characteristics is the two-stage heating system, which allows the furnace to operate at a lower stage when the heating demand is modest, providing improved comfort and energy efficiency. This feature also minimizes temperature fluctuations, ensuring a more consistent and comfortable indoor environment.

Energy efficiency is a critical aspect of the Bryant 581J. With an annual fuel utilization efficiency (AFUE) rating of up to 96%, this furnace is designed to convert a high percentage of fuel into usable heat, which helps homeowners save on energy bills. The high-efficiency design also contributes to a reduced carbon footprint, aligning with modern environmental concerns.

The Bryant 581J is equipped with technologically advanced features, including the ComfortTechâ„¢ control system. This system enables enhanced temperature regulation and integrates easily with smart home systems, allowing homeowners the convenience of remote control through smartphones and tablets. Additionally, the furnace includes an electronically commutated motor (ECM) blower, which optimizes airflow and reduces energy consumption while enhancing the overall comfort level within the space.

Noise reduction is another key characteristic of the Bryant 581J. The furnace is engineered with sound-dampening technology, resulting in quieter operation compared to conventional furnaces. This attention to noise management makes it an appealing choice for residential applications, where peace and tranquility are crucial.

The durable construction of the Bryant 581J ensures longevity and reliability. With a robust cabinet and quality materials, it is built to withstand the rigors of daily operation. Furthermore, the furnace comes with a warranty that provides peace of mind, protecting the investment over the years.

Overall, the Bryant 581J represents a blend of efficiency, advanced technology, and reliable performance. With its high AFUE rating, innovative features, and quiet operation, it stands out in the market as a top choice for anyone seeking a dependable heating solution. Whether for new installations or replacements, the Bryant 581J is designed to meet the heating demands of today's energy-conscious homeowners.