Roberts Gorden CRV-B-6, CRV-B-8, CRV-B-2, CRV-B-4 service manual Table of Figures

Page 5

TABLE OF FIGURES

 

Figure 1: Assembly Overview (Two Branch System Shown)

3

Figure 2: Standard Reflector

6

Figure 3: One Side Reflector

6

Figure 4: Two Side Reflectors

6

Figure 5: Universal Shield, Position 1

7

Figure 6: Universal Shield, Position 2

7

Figure 7: Universal Shield, Position 3

7

Figure 8: 2-Foot Deco Grille

8

Figure 9: Barrier Shield

8

Figure 10: Protective Grille

8

Figure 11: Radiant Distribution (Average Coverage)

11

Figure 12: Radiant Distribution (Increased Coverage)

11

Figure 13: Radiant Distribution (Heavy Coverage)

11

Figure 14: Burner Flow Units

13

Figure 15: Vacuum Loss Curve for 4" Shared Tailpipe

14

Figure 16: Tube Length vs. Efficiency

16

Figure 17: Possible Damper Coupling Locations

20

Figure 18: Example System Layout (Option 1)

21

Figure 19: Example System Layout (Option 2)

22

Figure 20: Example System Layout (Option 3)

22

Figure 21: Example System Layout (Option 4)

23

Figure 22: Example System Layout (Option 5)

23

Figure 23: Example System Layout (Option 6)

24

Figure 24: Example System Layout (Option 7)

24

Figure 25: Example System Layout (Option 8)

24

Figure 26: Example System Layout (Option 9)

25

Figure 27: Air Supply System Capacity by Duct Length and

 

Diameter

28

Figure 28: Outside Air Blower

29

Figure 29: Sample Layout for Pressurized Outside Air

 

Systems

30

LIST OF TABLES

 

Table 1: CORAYVAC® Design Parameters

12

Table 2: Pump Capacity

14

Table 3: Pump Exhaust Requirements

14

Table 4: Allowable Tailpipe Lengths

17

Table 5: Operating Characteristics; Condensing or

 

Non-Condensing

18

Image 5
Contents Design Manual Page Roberts-Gordon LLC Page Table of Figures Page Concept Zero Regulator SafetyCRV-SERIES System Assembly Overview Two Branch System Shown Fuel Savings and Comfort Clearances to combustibles at all times for safety ONE Side Reflector Standard ReflectorUniversal SHIELD, Position Foot Deco Grille Radiant Height Adjustment Factor Radiant Adjustment to Heat LossSizing and Design Considerations ExampleRadiant Distribution Selecting the BurnersRadiant Distribution Average Coverage Radiant Distribution Increased Coverage= mounting height Radiant Branch Flow Flow LoadingBurner Flow Units Pump Exhaust Length Requirements Pump CapacityTailpipe Flow Radiant Tube Length Radiant Tube and TailpipeMinimum Radiant Tube Length Maximum Radiant Tube LengthPump Model Series Maximum Loading Design ParametersCRV-Series Design Methods Flow Units Per BranchAllowable Tailpipe Lengths Burner Model After Each BurnerRule of Thumb Unshared Calculations Tailpipe Design MethodSystem with EP-300 Series Pump To Calculate the Total System TailpipeDamper Couplings Possible Damper Coupling Locations Example System Layout Option Example CRV-SERIES System Layouts12 m 10 3 m 20 6 m 12 m Tailpipe 10 3 m 100 30 m Example System Layout Option 7, 8 Roberts Gordon Ultravac Control MethodsRoberts Gordon System Control P/N Pressure Switch Pressurized AIR Supply SystemNon-Pressurized Pressurized SystemsBlower P/N 90707501 Performance 112 Flow Units Pipe sizingDuct Design Rules Sample Layout for Pressurized Outside Air Systems Roberts Gordon Ultravac Design Requirements CRV-SERIES Equipment Specifications Page Maintain Clearance Side Clearance below
Related manuals
Manual 72 pages 5.13 Kb

CRV-B-4, CRV-B-2, CRV-B-6, CRV-B-8 specifications

Roberts Gorden is renowned for its innovative heating solutions, particularly the CRV series of infrared radiant heaters, which include models CRV-B-2, CRV-B-4, CRV-B-6, and CRV-B-8. These heaters are designed to provide effective and efficient heating, making them ideal for various industrial, commercial, and agricultural applications.

One of the standout features of the Roberts Gorden CRV series is its advanced infrared heating technology. Unlike conventional heating systems that heat the air, infrared heaters warm objects and people directly, allowing for a more energy-efficient and comfortable environment. This makes the CRV series particularly effective in large spaces, such as warehouses, manufacturing facilities, and greenhouses.

The CRV-B models are engineered for versatility and can be mounted in various configurations, including horizontal and vertical placements, providing installation flexibility. Each model is available in different sizes and heating outputs, ensuring that users can select a unit tailored to their specific heating requirements. The CRV-B-2, for instance, is ideal for smaller spaces, while the CRV-B-8 offers higher power for larger areas.

Moreover, these heaters come equipped with advanced control systems that allow for precise temperature regulation. The units can be integrated with building management systems, enabling users to monitor and adjust settings remotely. This feature not only enhances comfort but also contributes to energy savings, as the heaters can be programmed to operate only during necessary hours.

Structural durability is another significant characteristic of the CRV series. Constructed with high-quality materials, the heaters are designed to withstand the rigors of industrial environments while maintaining optimal performance over time. The reflective surfaces enhance heat distribution, ensuring that warmth is evenly distributed throughout the space.

Safety is paramount with Roberts Gorden’s CRV heaters. They are designed with built-in safety mechanisms, including overheat protection and automatic shut-off features to prevent accidents.

Overall, the Roberts Gorden CRV-B-2, CRV-B-4, CRV-B-6, and CRV-B-8 models exemplify cutting-edge infrared heating technology, delivering effective, efficient, and reliable heating solutions tailored to diverse applications. With a combination of flexibility, advanced control capabilities, and safety features, these heaters are an excellent choice for anyone in need of powerful heating solutions.