White Rodgers PS9 Up service manual Section I USER’S Information, Table of Contents, Safety

Page 1

USER’S INFORMATION, MAINTENANCE AND SERVICE MANUAL

HIGH EFFICIENCY

TUBULAR HEAT EXCHANGER SERIES

MODELS: PS9*UP / FC9S*UP / FL9S*UP (Single Stage Upflow)

EFFICIENCY

RATING

CERTIFIED

ISO 9001

Certified Quality

Management System

TABLE OF CONTENTS

CONTACT INFORMATION

1

SERVICE AND MAINTENANCE MANUAL

.5

USER’S INFORMATION

1

SAFETY SECTION

.5

SAFETY

1

FURNACE MAINTENANCE SECTION

.5

INSTRUCTIONS FOR EXAMINING THE

 

SEQUENCE OF OPERATION

.5

FURNACE INSTALLATION

2

Continuous Blower

.5

HOW YOUR GAS FURNACE WORKS

3

Intermittent Blower - Cooling

.5

START-UP AND SHUTDOWN INSTRUCTIONS

3

Heating Cycle

.5

Read the Instructions Below Before Trying to Start the Furnace . .

3

Hot Surface Ignition System

.6

Operating Instructions:

3

TROUBLESHOOTING

.6

To Turn Off the Appliance:

3

FURNACE CONTROL DIAGNOSTICS

.6

FURNACE USER MAINTENANCE

3

DIAGNOSTIC FAULT CODE STORAGE AND RETRIEVAL

.7

Air Filters

4

REPLACEMENT PARTS LIST

.8

Replacing Filters

4

REPLACEMENT PART CONTACT INFORMATION

10

Blower Care

4

WIRING DIAGRAM

11

Motor Lubrication

5

LIMITED WARRANTY

12

CONTACT INFORMATION

Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions.

Contact us by mail:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

The manufacturer recommends that the user read all sec- tions of this manual and keep the manual for future refer- ence.

FIRE OR EXPLOSION HAZARD - Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone (included cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas sup- plier.

SECTION I: USER’S INFORMATION

SAFETY

1.The furnace area must be kept clear and free of combustible mate- rials, gasoline and other flammable vapors and liquids.

2.Insulating materials may be combustible. The furnace must be kept free and clear of insulating materials. The furnace area must be examined when installed in an attic or other insulated space or when insulation is added to be sure that the insulation material has been kept away from the furnace.

3.The furnace needs air for combustion in order to operate properly and safely. Do not block or obstruct air openings on the furnace, air openings to the area where the furnace is installed, or spaces around the furnace.

4.Follow the instructions exactly as shown on the OPERATING INSTRUCTION LABEL or the Start-up and Shutdown Instructions on Page 3 of this manual when lighting the furnace or turning the furnace off.

5.Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off the electrical supply.

6.Do not use this furnace if any part has been under water. A flood- damaged furnace is extremely dangerous. Attempts to use the fur- nace can result in fire or explosion. A qualified service agency should be contacted to inspect the furnace and replace all gas controls, control system parts, electrical parts that have been wet or the furnace if deemed necessary.

269434-UUM-A-0407

Image 1
Contents Safety Table of ContentsSection I USER’S Information Contact InformationFire or Explosion Hazard Instructions for Examining the Furnace InstallationHOW Your GAS Furnace Works Furnace User MaintenanceTo Turn Off the Appliance START-UP and Shutdown InstructionsReplacing Filters Air FiltersBlower Care Safety Section Section II Service and Maintenance ManualFurnace Maintenance Section Sequence of OperationFurnace Control Diagnostics TroubleshootingHot Surface Ignition System HOT Surface Ignition SystemIgnition Control Diagnostic Fault Code Storage and RetrievalSection III Replacement Parts List Electrical Item Description MotorAIR Moving Fabricated PartsModel no Description Used with Replacement Part Contact InformationWiring Diagram Section IV Wiring DiagramUnitary 5005 Norman Products York Group Drive 73069 Exclusions

FL9s UP, FC9s Up, PS9 Up specifications

White Rodgers has long been synonymous with innovation in the HVAC industry, and its series of thermostats, including the FC9s Up, PS9 Up, and FL9s Up, exemplify this commitment to quality and technology. These programmable thermostats are designed to enhance energy efficiency, comfort, and control for both residential and commercial applications.

The FC9s Up is a standout in the lineup, featuring a user-friendly interface that makes it easy for homeowners to program their heating and cooling schedules. It supports multi-stage heating and cooling systems, allowing for precise temperature control across various zones. Its Smart Set technology enables the thermostat to learn users' habits over time, automatically adjusting to optimize energy use without sacrificing comfort. Furthermore, the FC9s Up is compatible with a range of home automation systems, offering seamless integration for tech-savvy users.

The PS9 Up brings another layer of versatility with its advanced sensor technology. This model is particularly notable for its responsive touch screen and intuitive controls. The PS9 Up is designed to monitor humidity levels, adjusting the operation of HVAC systems accordingly, which not only conserves energy but also enhances indoor air quality. Users can customize settings to align with their lifestyle, ensuring comfort throughout the day and night.

Lastly, the FL9s Up stands out with its robust features tailored for commercial applications. It provides advanced analytics that allow business owners to monitor and manage energy consumption effectively. The FL9s Up’s compatibility with various heating and cooling systems, including geothermal and radiant floor heating, makes it a versatile choice for larger or more complex environments. Moreover, its built-in Wi-Fi capability enables remote access via a smartphone or tablet, allowing users to control their systems from anywhere, ensuring optimal conditions even when they're away.

Together, the FC9s Up, PS9 Up, and FL9s Up represent the evolution of thermostat technology, backed by White Rodgers' decades of experience and commitment to efficiency. Each model offers unique features and capabilities tailored to different needs and environments, ultimately making temperature management more accessible and energy-efficient for users everywhere. Whether for residential or commercial applications, these thermostats set a high standard in the HVAC industry, driving energy savings and enhancing comfort with every use.