Heat & Glo LifeStyle 6000CMOD-IPI Install Trim and/or Surround, Air Shutter Setting, Fully Open

Page 55

G. Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 14.7).

Replacing Fixed Glass Assembly

Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame.

LATCHES

(BOTH BOTTOM

AND TOP)

GLASS

ASSEMBLY

Figure 14.7 Fixed Glass Assembly

H. Install Trim and/or Surround

Install optional trim kits and/or surrounds using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model).

I. Air Shutter Setting

Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.8.

Loosen the wing nut.

Move the air handle to the left to open the air shutter.

Move the air handle to the right to close the air shutter.

Tighten the wing nut.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

Appearance of

components may vary.

AIR SHUTTER

WING NUT

Figure 14.8 Air Shutter

Air Shutter Settings

 

NG

LP

6000

Fully Closed

Fully Open

8000

Fully Open

Fully Open

Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI2241-900 Rev. H • 5/12

55

Image 55
Contents HOT Surfaces What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Electrical Codes Listing and Code ApprovalsNon-Combustible Materials Specification Combustible Materials SpecificationRequirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalControl Module Operation IPI Battery Tray/Battery InstallationModule Reset Nine Hour Safety Shutdown FeatureGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Burner Ignition and Operation Interior Ceramic Glass Panel CleaningFirebox Control Compartment and Firebox TopMAY Vary Appearance8000CMOD-IPI NG Burner Identification6000CMOD-IPI NG 6000CMOD-IPI LPTypical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and Components8000 Framing and ClearancesSelecting Appliance Location 60008000 Constructing the Appliance ChaseClearances 6000Combustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsInches U.S.A Covered Alcove ApplicationsUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table Key8000CMOD-IPI Vent Diagrams Top Vent Horizontal TerminationOne Elbow 6000CMOD-IPIV1 Minimum H1 + H2 Maximum Two ElbowsMin Max Top Vent Horizontal Termination Three ElbowsBreak Here Maximum + V 2 Min Top Vent Vertical TerminationH1 + H2 V1 + V2 Minimum H1 + H2 Maximum Top Vent Vertical Termination Three ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP SLP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Flat Ceiling InstallationTop Vent Appliance PreparationSecuring and Leveling the Appliance Installing the Non-combustible BoardHeader Assemble Pipe Sections Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingInstall Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination DVP-HPC1 DVP-HPC2 Install Horizontal Termination Cap DVP and SLP PipeGas Pressure High Altitude InstallationsGas Information Fuel ConversionElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsWall Switch Installation for Fan Optional Electrical Service and Repair Junction Box InstallationFinishing Painting Facing MaterialFinish and Sealing Joints Finishing Around Opening with Gypsum WallboardFolio Door Application Door SelectionCmod Door Application Door FIT Finish Material See Thickness Finishing Material Inch Thick or Less Overlap Fit MethodNON-COMBUSTIBLE Finishing Material Models Finishing Material Inches Inside Fit MethodAppliance Setup Remove Screw Media PlacementBurner Fully Open Install Trim and/or SurroundAir Shutter Setting Air Shutter SettingsSymptom Possible Cause Corrective Action TroubleshootingIntelliFire PlusTM Ignition System Troubleshooting Reference Materials Appliance Dimension DiagramLocation Inches Millimeters GAS Line Access R Left Side TOP View Front View Right View DVP-AS2 Vent Components DiagramsHorizontal Termination Cap DVP-TRAPCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLDVP-TVHW SLP-LPC Optional Wire HarnessDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP PVI-SLPEffective Height Length 222 mm 165 mm 165 mm9-1/4 235 mm 152 mm 168 mmElbow 251 mmDVP-2SL DVP-HSM-B SLK-SNKD SLP-CCS-BK SLP-TVHWSLP-DCF-BK SLP-WT-BK Modern Direct Vent Fireplace Service PartsStocked At Depot8000CMOD-IPI 8000CMOD-IPI #12 Valve AssemblyBattery Pack 2166-323 Service Parts ListContact Information

6000CMOD-IPI, 8000CMOD-IPI specifications

The Heat & Glo LifeStyle 6000CMOD-IPI and 8000CMOD-IPI models represent the pinnacle of modern fireplace design, marrying aesthetics with advanced technology to create a unique heating experience. These versatile, linear gas fireplaces are designed to seamlessly integrate into any living space while offering exceptional performance and style.

One of the standout features of the LifeStyle series is its impressive heating efficiency. Both models utilize advanced heating technology to maximize warmth while minimizing energy consumption. The innovative IPI (Intermittent Pilot Ignition) system enhances efficiency by using a pilot light only when the fireplace is in use, ensuring that energy costs remain low.

The design of the LifeStyle series is both contemporary and customizable. Homeowners have the option to choose from various finishes, media styles, and decorative elements. The large, expansive viewing area enhances the ambiance of any room, showcasing the mesmerizing flames. The 6000CMOD-IPI with its 60-inch firebox and the 8000CMOD-IPI with an 80-inch firebox add a dramatic focal point to any setting.

Another significant innovation incorporated in these models is the use of advanced flame technology. This feature allows for an adjustable flame height, providing flexibility in terms of heat output and visual effects. Users can tailor the flames to suit mood and occasion, whether they desire a cozy ambiance for a quiet evening or a more robust heat output for entertaining.

The user-friendly controls add to the convenience of the LifeStyle series. Homeowners can easily operate the fireplace with a remote control or smart home integration, enabling adjustments from the comfort of their seating. Additionally, the fireplaces come equipped with a safety shut-off feature, providing peace of mind while enhancing user safety.

Maintenance is simplified with the LifeStyle series as well. The design minimizes creosote buildup and offers easy access for cleaning. The contemporary linear design also allows for easy installation, making it an appealing choice for both new builds and renovations.

In summary, the Heat & Glo LifeStyle 6000CMOD-IPI and 8000CMOD-IPI models combine cutting-edge heating technology, elegant design, and user-friendly features. These fireplaces not only serve as a source of comfort but also enhance the aesthetic appeal of any living space, making them a valuable addition for homeowners looking to elevate their interiors with warmth and style.