Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

 

A. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

4. Pilot lights but contin-

sensing rod.

connections underneath pilot assembly are tight. Verify

ues to spark, and main

 

flame sense or igniter wires are not grounding out to metal

burner will not ignite.

 

chassis, pilot burner, pilot enclosure or screen if present, or

(If the pilot continues

 

any other metal object.

to spark after the

 

 

B. Poor flame rectification or contaminated

With fixed glass assembly in place, verify that flame is en-

pilot flame has been lit,

flame sensing rod.

gulfing flame sensing rod on left side of pilot hood. Flame

flame rectification has

 

sensing rod should glow shortly after ignition. With a multi-

not occurred.)

 

 

meter, verify that current in series between module and

 

 

 

 

sense lead is at least 0.14 microamps. Verify correct pilot

 

 

orifice is installed and gas inlet is set to pressure specifi-

 

 

cations. Polish flame sensing rod with fine steel wool to

 

 

remove any contaminants that may have accumulated on

 

 

flame sensing rod.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

 

 

pliance. Verify that wire harness is firmly connected to the

 

 

module.

 

 

 

 

D. Damaged pilot assembly or contami-

Verify that ceramic insulator around the flame sensing rod

 

nated flame sensing rod.

is not cracked, damaged, or loose. Verify connection from

 

 

flame sensing rod to white sensor wire. Polish flame sens-

 

 

ing rod with fine steel wool to remove any contaminants

 

 

that may have accumulated on flame sensing rod. Verify

 

 

continuity with a multi-meter with ohms set at lowest range.

 

 

Replace pilot if any damage is detected.

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position.

 

 

Remove ignitor wire “I” from module. Place ON/OFF rocker

 

 

switch or wall switch in ON position. If there is no spark at “I”

 

 

terminal module must be replaced. If there is a spark at “I”

 

 

terminal, module is fine.

 

 

 

Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI2241-900 Rev. H • 5/12

57

Image 57
Contents What to do if you smell gas HOT SurfacesHot glass will cause burns Homeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Non-Combustible Materials Specification Listing and Code ApprovalsCombustible Materials Specification Electrical CodesRequirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceModule Reset IPI Battery Tray/Battery InstallationNine Hour Safety Shutdown Feature Control Module OperationFinal inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveFrequently Asked Questions Issue SolutionsAfter Fireplace is Lit Maintenance and Service Firebox Interior Ceramic Glass Panel CleaningControl Compartment and Firebox Top Burner Ignition and OperationMAY Vary Appearance6000CMOD-IPI NG Burner Identification6000CMOD-IPI LP 8000CMOD-IPI NGTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Any such action may cause a fire hazardSelecting Appliance Location Framing and Clearances6000 8000Clearances Constructing the Appliance Chase6000 8000Mantel and Wall Projections Combustible MantelsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsInches U.S.A Covered Alcove ApplicationsApproved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsOne Elbow Vent Diagrams Top Vent Horizontal Termination6000CMOD-IPI 8000CMOD-IPIV1 Minimum H1 + H2 Maximum Two ElbowsMin Max Top Vent Horizontal Termination Three ElbowsBreak Here Maximum + V 2 Min Top Vent Vertical TerminationH1 + H2 V1 + V2 Minimum H1 + H2 Maximum Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Install the Ceiling FirestopInstalling the Optional Heat-ZoneGas Kit Install Attic Insulation ShieldFlat Ceiling Installation Vaulted Ceiling InstallationTop Vent Appliance PreparationInstalling the Non-combustible Board Securing and Leveling the ApplianceHeader Attach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination DVP-HPC1 DVP-HPC2 Install Horizontal Termination Cap DVP and SLP PipeGas Information High Altitude InstallationsFuel Conversion Gas PressureIntelliFire PlusTM Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationWall Switch Installation for Fan Optional Electrical Service and Repair Junction Box InstallationFinishing Finish and Sealing Joints Facing MaterialFinishing Around Opening with Gypsum Wallboard PaintingDoor Selection Folio Door ApplicationCmod Door Application Finishing Material Inch Thick or Less Overlap Fit Method Door FIT Finish Material See ThicknessNON-COMBUSTIBLE Finishing Material Models Finishing Material Inches Inside Fit MethodAppliance Setup Remove Screw Media PlacementBurner Air Shutter Setting Install Trim and/or SurroundAir Shutter Settings Fully OpenTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire PlusTM Ignition System Troubleshooting Appliance Dimension Diagram Reference MaterialsLocation Inches Millimeters GAS Line Access R Left Side TOP View Front View Right View DVP-AS2 Vent Components DiagramsHorizontal Termination Cap DVP-TRAPBEK DVP-BEK2 RF6M RF12MDVP-TRAPFL COOL-ADDDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Optional Wire HarnessPVI-SLP SLP-LPCElbow 222 mm 165 mm 165 mm9-1/4 235 mm 152 mm 168 mm251 mm Effective Height LengthSLK-SNKD SLP-CCS-BK SLP-TVHW DVP-2SL DVP-HSM-BSLP-DCF-BK SLP-WT-BK Stocked Service PartsAt Depot Modern Direct Vent Fireplace8000CMOD-IPI 8000CMOD-IPI #12 Valve AssemblyBattery Pack 2166-323 Service Parts ListContact Information

6000CMOD-IPI, 8000CMOD-IPI specifications

The Heat & Glo LifeStyle 6000CMOD-IPI and 8000CMOD-IPI models represent the pinnacle of modern fireplace design, marrying aesthetics with advanced technology to create a unique heating experience. These versatile, linear gas fireplaces are designed to seamlessly integrate into any living space while offering exceptional performance and style.

One of the standout features of the LifeStyle series is its impressive heating efficiency. Both models utilize advanced heating technology to maximize warmth while minimizing energy consumption. The innovative IPI (Intermittent Pilot Ignition) system enhances efficiency by using a pilot light only when the fireplace is in use, ensuring that energy costs remain low.

The design of the LifeStyle series is both contemporary and customizable. Homeowners have the option to choose from various finishes, media styles, and decorative elements. The large, expansive viewing area enhances the ambiance of any room, showcasing the mesmerizing flames. The 6000CMOD-IPI with its 60-inch firebox and the 8000CMOD-IPI with an 80-inch firebox add a dramatic focal point to any setting.

Another significant innovation incorporated in these models is the use of advanced flame technology. This feature allows for an adjustable flame height, providing flexibility in terms of heat output and visual effects. Users can tailor the flames to suit mood and occasion, whether they desire a cozy ambiance for a quiet evening or a more robust heat output for entertaining.

The user-friendly controls add to the convenience of the LifeStyle series. Homeowners can easily operate the fireplace with a remote control or smart home integration, enabling adjustments from the comfort of their seating. Additionally, the fireplaces come equipped with a safety shut-off feature, providing peace of mind while enhancing user safety.

Maintenance is simplified with the LifeStyle series as well. The design minimizes creosote buildup and offers easy access for cleaning. The contemporary linear design also allows for easy installation, making it an appealing choice for both new builds and renovations.

In summary, the Heat & Glo LifeStyle 6000CMOD-IPI and 8000CMOD-IPI models combine cutting-edge heating technology, elegant design, and user-friendly features. These fireplaces not only serve as a source of comfort but also enhance the aesthetic appeal of any living space, making them a valuable addition for homeowners looking to elevate their interiors with warmth and style.