C. 240VAC Hardwire Installation
(Minimum 14 gauge three conductor wire,
•Turn off circuit breaker.
•Remove access knockout located on the right side of heater.
•Disconnect black and white wires between the heater and plug. Remove the power cord. Remove the electrical knockout and install the cable clamp (not provided). Remove the connectors on the wires from the heater and strip them back 1/2 in.
•Feed 8 in. of service wire through cable clamp (not provided) and secure.
•Connect black, white and red wires of the heater to the black, white and red wires from the service. Connect green (ground) wire from heater to the ground of the service. See Figure 4.1.
•Wall switch wiring (see below) is to be done at this time.
•Cover the access hole with a 4 in. cover plate (not provided) if required.
•Remove the protective cover by cutting the tape located on the outer perimeter.
D. Wall Switch Wiring (12VDC)
*Do not connect wires to 120/240VAC* (hardwired heat- ers only)
•Turn off circuit breaker.
•Remove access knockout located on the right side of heater.
•Feed 8 in. of wire for the wall switch through the cable clamp and secure. Low voltage wire can be used for the wall switch connection. It is recommended to only go 10 ft from the heater to the wall switch.
•Locate the light blue (wall switch) wires in the heater. Connect one wall switch (blue) wire to wire for switch and connect the other wall switch (blue) wire to the other wire for switch.
•Cover the access hole with a 4 in. cover plate (not provided) if required.
•Run the wall switch wire to the wall box and connect to a wall switch
LAMP LAMP
120VAC
LAMPS
DIMMER
B
A
GROUND
NEUTRAL
120VAC 60Hz
LINE1 HOT
120VAC 60Hz | 240VAC 60Hz |
| LINE2 HOT |
120VAC PLUG or 120/240VAC HARD WIRED
FLAME MOTOR | B | A |
R2 |
SPEED CONTROL
OPTIONAL |
|
|
| |
|
| D1 | THERMOSTAT | |
REMOTE OR | REMOTE | RELAY | ||
DIODE | ||||
WALL ON/OFF | HEAT |
|
| |
SWITCH | CONTROL |
|
| |
|
|
| HEAT SWITCH |
-+
12VDC
SUPPLY
POWER | WHITE |
| BLOWER |
| BLOWER | ||
|
| ||
|
| 120VAC |
|
BLACK | HIGH LIMIT HEATER1 | HIGH LIMIT | |
HEATER1 | |||
|
|
| BLACK |
|
|
| 240VAC |
| RED |
| HEATER2 |
|
|
| RED |
3PIN WIRING HARNESS
120VAC - 240VAC 60HZ
POWER NEUTRAL MUST NOT CONNECT TO VIRTUAL NEUTRAL OF HEATERS OR BLOWER IN 240VAC VERSION
Figure 4.1 120V/240V Wiring Diagram
10 | Heat & Glo • CRESTFIRE Series Electric Fireplace • |