Heat & Glo LifeStyle CF550EV, CF750E 240VAC Hardwire Installation, Wall Switch Wiring 12VDC

Page 10

C. 240VAC Hardwire Installation

(Minimum 14 gauge three conductor wire, non-metallic sheathing with ground.)

Turn off circuit breaker.

Remove access knockout located on the right side of heater.

Disconnect black and white wires between the heater and plug. Remove the power cord. Remove the electrical knockout and install the cable clamp (not provided). Remove the connectors on the wires from the heater and strip them back 1/2 in.

Feed 8 in. of service wire through cable clamp (not provided) and secure.

Connect black, white and red wires of the heater to the black, white and red wires from the service. Connect green (ground) wire from heater to the ground of the service. See Figure 4.1.

Wall switch wiring (see below) is to be done at this time.

Cover the access hole with a 4 in. cover plate (not provided) if required.

Remove the protective cover by cutting the tape located on the outer perimeter.

D. Wall Switch Wiring (12VDC)

*Do not connect wires to 120/240VAC* (hardwired heat- ers only)

Turn off circuit breaker.

Remove access knockout located on the right side of heater.

Feed 8 in. of wire for the wall switch through the cable clamp and secure. Low voltage wire can be used for the wall switch connection. It is recommended to only go 10 ft from the heater to the wall switch.

Locate the light blue (wall switch) wires in the heater. Connect one wall switch (blue) wire to wire for switch and connect the other wall switch (blue) wire to the other wire for switch.

Cover the access hole with a 4 in. cover plate (not provided) if required.

Run the wall switch wire to the wall box and connect to a wall switch (WSK-21 & WSK-21-W).

LAMP LAMP

120VAC

LAMPS

DIMMER

B

A

GROUND

NEUTRAL

120VAC 60Hz

LINE1 HOT

120VAC 60Hz

240VAC 60Hz

 

LINE2 HOT

120VAC PLUG or 120/240VAC HARD WIRED

FLAME MOTOR

B

A

R2

SPEED CONTROL

-12VDC

OPTIONAL

 

 

 

 

 

D1

THERMOSTAT

REMOTE OR

REMOTE

RELAY

DIODE

WALL ON/OFF

HEAT

 

 

SWITCH

CONTROL

 

 

 

 

 

HEAT SWITCH

-+

12VDC

SUPPLY

POWER

WHITE

 

BLOWER

 

BLOWER

 

 

 

 

120VAC

 

-12VDC

BLACK

HIGH LIMIT HEATER1

HIGH LIMIT

HEATER1

 

 

 

BLACK

 

 

 

240VAC

 

RED

 

HEATER2

 

 

 

RED

3PIN WIRING HARNESS

120VAC - 240VAC 60HZ SPLIT-PHASE

POWER NEUTRAL MUST NOT CONNECT TO VIRTUAL NEUTRAL OF HEATERS OR BLOWER IN 240VAC VERSION

￿Figure 4.1 120V/240V Wiring Diagram

10

Heat & Glo • CRESTFIRE Series Electric Fireplace • 4030-239 Rev J • 04/05

Image 10
Contents CF550EV Listing Label Information/Location Homeowner Reference InformationHeater Serial # Model Table of Contents Listing and Code Approvals CertificationImportant Instructions Getting StartedNot intended for use as a primary heat source Tools and Supplies Needed Fire RiskClearances Framing and ClearancesSelecting Heater Location Electrocution RiskFraming 30 in. min 762 mm In. 12 in mm 305 mm 356 mm120VAC Wall Outlet Installation Wiring120VAC Hardwire Installation 240VAC Hardwire Installation Wall Switch Wiring 12VDCSecure and Level the Heater Heater PreparationShock Risk Fire Risk Finishing Material Finishing ChecklistFinishing Combustible MaterialMantel CeilingAccessories Heater SetupClean Heater Remove Shipping MaterialsManual Controls Access ControlsOperating Instructions Function of Manual ControlsHand Held Remote Control Transmitter RCE-HNG-B Optional FCC Requirements Wall Switch ControlCanadian Equipment Requirements Troubleshooting Guide TroubleshootingIssues Possible Causes Solutions Cleaning the Glass Doors and Back Acrylic Panel Maintenance and ServiceCleaning the Firebox and Control Compart- ment Replacing the Light BulbsHeater/Blower Assembly Maintenance Maintenance Task ListHeater Dimensions Reference MaterialsOptional Components RCE-HNG-BTrim Kits FrontsLeft Right Surrounds Marble LuxService Parts Crestfire# Description of Part CF550E Series CF750E Series Qty Warranty Limited WarrantyContact Information