Heat & Glo LifeStyle CF750EV, CF550ENH Heater/Blower Assembly Maintenance, Maintenance Task List

Page 20

D. Heater/Blower Assembly Maintenance

Turn off the circuit breaker/unplug the heater before servicing the heater/blower assembly.

Allow heater to cool before removing.

Open the lower grille panel to view the dashboard on the heater (the lower grille may need to be removed).

Remove the four outer screws. See Figure 10.2.

Pull dashboard towards you to expose the light compartment (the light tray does not need to be pulled all of the way out of the heater).

Reach into the back of the left rear corner of the light tray and unplug wire harness from connector. To remove plug, squeeze both sides and pull.

Remove the hood by pulling it straight out.

Remove the upper grille panel/door front by lifting it up and out.

Remove the four outer screws. See Figure 10.2.

Pull the heater/blower assembly out of heater.

Slide the heater/blower assembly back into the heater, making sure that the wires do not touch the heater/blower assembly housing.

Once the front of the heater/blower assembly is fl ush with heater, reinstall the four screws removed earlier.

Replace the upper grille panel and hood.

Plug the wire harness back into the connector in the back of the left rear corner of the light tray.

Slide dashboard back into heater and make sure all wires are inside heater.

Reinstall the four screws removed earlier.

Turn on the circuit breaker or plug the heater back into the wall outlet.

Remove

Outer

Screws

Figure 10.2 Installing Heater/Blower Assembly

E. Maintenance Task List

Inspect

 

Maintenance Tasks

Glass Doors

1.

Inspect glass panels for cracks. Replace if this condition is present.

 

 

 

 

2.

Confi rm there is no damage to glass or glass frame. Replace as necessary.

 

3.

Clean glass using a non-abrasive cleaner such as Brasso©.

 

 

 

Circulation Compartment

1.

Remove any foreign objects.

 

2.

Verify unobstructed air circulation.

20

Heat & Glo • CRESTFIRE Series Electric Fireplace • 4030-239 Rev J • 04/05

Image 20
Contents CF550EV Heater Serial # Model Homeowner Reference InformationListing Label Information/Location Table of Contents Listing and Code Approvals CertificationNot intended for use as a primary heat source Getting StartedImportant Instructions Tools and Supplies Needed Fire RiskFraming and Clearances Selecting Heater LocationClearances Electrocution RiskFraming 30 in. min 762 mm In. 12 in mm 305 mm 356 mm120VAC Hardwire Installation Wiring120VAC Wall Outlet Installation 240VAC Hardwire Installation Wall Switch Wiring 12VDCShock Risk Fire Risk Heater PreparationSecure and Level the Heater Finishing Checklist FinishingFinishing Material Combustible MaterialMantel CeilingHeater Setup Clean HeaterAccessories Remove Shipping MaterialsAccess Controls Operating InstructionsManual Controls Function of Manual ControlsHand Held Remote Control Transmitter RCE-HNG-B Optional Canadian Equipment Requirements Wall Switch ControlFCC Requirements Issues Possible Causes Solutions TroubleshootingTroubleshooting Guide Maintenance and Service Cleaning the Firebox and Control Compart- mentCleaning the Glass Doors and Back Acrylic Panel Replacing the Light BulbsHeater/Blower Assembly Maintenance Maintenance Task ListHeater Dimensions Reference MaterialsOptional Components RCE-HNG-BLeft Right FrontsTrim Kits Surrounds Marble LuxService Parts Crestfire# Description of Part CF550E Series CF750E Series Qty Warranty Limited WarrantyContact Information