SAFETY AND WARNING INFORMATION

!READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the

!Owners Guide.

DO NOT USE this appliance if any part has been under water. Immediately CALL a

!qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

!THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be PERFORMED by a qualified service person. The

!appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.

!Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the

!appliance CLEAR of all obstacles and materials for servicing and proper operations. Due to the high temperature, the appliance should be LOCATED out of traffic areas

!and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.

Children and adults should be ALERTED to the hazards of high surface temperature

!and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.

!These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide. NO OTHER vent systems or components MAY BE USED.

!This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are PROHIBITED.

!INSPECT the external vent cap on a regular basis to make sure that no debris is interfering with the air flow.

!The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass door removed, cracked, or broken.

!Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.

!The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.

!DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is recommended that a qualified

!service technician perform an appliance check-up at the beginning of each heating season.

Any safety screen or guard removed for servicing must be replaced before operating

!this appliance.

Image 2
Contents Heat-N-Glo Safety and Warning Information Contents Approvals and Codes Approval Listings Installation CodesHigh Altitude Installations CodesIf YOU are Using the Rear SET of Vent Collars Getting StartedANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 6000ARCH Fireplace Ceiling Installing the Fireplace Step LocatingClearance Requirements Model Step Framing FireplaceAt Wall Firestops Identifying Vent Components Step Installing Vent SystemVent System Approvals DV-90D Straight UP Corner Installation Venting with ONE 1 90 Elbow For 6000TR & 6000XLT-CDN Venting with TWO 2 90 Elbows Venting with TWO 2 90 o Elbows 6000ARCHVenting with three 90 elbows Venting with Three 3 90 Elbows Venting Out the Top Vent Installing Vent Components For Model 6000TRVenting Out the Rear Vent Attach the First Vent Component to the Starting Collars Attaching the First Vent Component to the Starting CollarsAdding Venting Components 3. Install Support Brackets Continue Adding Vent ComponentsInstalling Support Brackets Install Firestops12 Hole and Vent Pipe 11 Hole and New Framing Members Vent Termination Attic FirestopRound & Trapezoid Termination Caps If Exterior Walls are Finished with This also pertains to vertical vent systems installed Minimum Height from Roof to Lowest Discharge Opening Standing Pilot Ignition System Step Positioning Leveling, Securing FireplaceStep Gas Control Systems Direct Spark Ignition DSI SystemStep Gas Supply Line Gas Controls SystemsStep Gas Pressure Requirements Pressure Natural Gas PropaneStep Wiring For Standing Pilot Ignition WiringFor Direct Spark Ignition DSI Wiring Fan Wiring DiagramIs found on model MicroswitchStep Finishing 6000ARCH onlyHearth Extensions Step Installing Trim Logs, Ember MaterialInstalling the Trim Positioning the Logs Placing the Ember MaterialModel 6000TR Glass Assembly Double-check for gas leaks Double-check for faulty componentsStep Before Lighting Fireplace Installation AfterFireplace Maintenance Maintaining and Servicing Your FireplaceBurner Flame Patterns Replacement Parts Accessories Standing Pilot with Robertshaw Controls onlyStanding Pilot with S.I.T. controls only Part Part Description Part NumberDSI Ignition Only Both Standing Pilot and DSI Ignition6000XLT-CDN 22 X 22 X6000XLS 22 X 6000ARCH 22 XAccessory Part Description Part Number

6000TR, 6000XLT-CDN, 6000XLS, 6000ARCH specifications

The Heat & Glo LifeStyle 6000 series offers a modern approach to home heating with its sleek designs and advanced technologies. The models within this series, including the 6000XLT-CDN, 6000TR, 6000XLS, and 6000ARCH, are designed for versatility and performance, catering to various aesthetic preferences and functional needs.

One of the standout features of the LifeStyle 6000 line is its linear design, which provides a contemporary aesthetic that fits seamlessly into any room. The 6000XLT-CDN model features a narrow, linear shape, making it an eye-catching centerpiece while providing efficient heating. The 6000TR offers a traditional configuration, with a classic appeal that remains timeless. The 6000XLS takes it a step further by incorporating an elongated view, while the 6000ARCH incorporates an arch design that adds architectural elegance.

Each model is equipped with Heat & Glo’s advanced LED lighting technology, which enhances the visual impact of the flames and creates a warm ambiance. This technology not only provides better illumination but also increases energy efficiency, allowing homeowners to enjoy the soothing glow without excessive energy consumption.

The series is also noted for its Smart Home compatibility, allowing users to control their fireplaces remotely through mobile devices. This feature adds convenience, enabling homeowners to adjust settings, monitor performance, and even program their fireplaces to suit their schedules.

Safety is paramount, and these models come equipped with advanced safety features, including a child lock and automatic shut-off systems. This ensures peace of mind for families while maintaining an inviting atmosphere.

Additionally, the LifeStyle 6000 series supports a range of fuel options, including gas and ethanol burners, providing flexibility according to user preferences and needs. With adjustable flame height and fan speed, users can customize their heating experience to match their comfort levels.

In summary, the Heat & Glo LifeStyle 6000 series blends style with functionality. With its modern designs, cutting-edge technology, and safety features, it provides a luxurious and efficient heating solution that enhances any living space. Whether you’re seeking a contemporary focal point or a traditional warmth, the 6000 series offers models that meet diverse needs while delivering exceptional performance.