Heat & Glo LifeStyle 36DV owner manual Installing Non-combustible Facing Material

Page 21

NON-COMBUSTIBLE

FACING MATERIAL

(SUPPLIED ATTACHED

TO BACK OF APPLIANCE)

APPLY FASTENERS

FROM FASTENER PACKET

IN THESE AREAS

Figure 7.2 Attaching Non-combustible Facing Material

C. Installing Non-combustible Facing Material

WARNING

Fire Risk.

Follow these instructions exactly.

Facing materials must be installed properly to prevent fire.

• No materials may be substituted without authorization by Hearth & Home Technologies.

Center and attach two top boards to the framing members. See Figure 7.2.

Attach left and right side pieces to framing members.

Use fasteners from fastener packet (in manual bag) in shaded areas.

Use regular sheetrock screws in non-shaded areas.

Use a wet or dry towel or soft brush to remove dust or dirt from facing material.

Apply a non-combustible adhesive to attach tile, stone or other non-combustible finishing materials per manufacturer’s instructions.

NON-COMBUSTIBLE ZONE

41 in.

54 in.

Figure 7.3 Complete Installation of Non-combustible Facing

Material

Heat & Glo • Escape-36DV2012-900 • Rev. AA • 04-08

21

Image 21
Contents Model Escape-36DV What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseHearth Extension Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Minimum MaximumV1 + V2 Minimum Maximum Top Vent Horizontal Termination Three ElbowsFlue Restrictor Instructions Top Vent Vertical Termination No Elbow V1 = 40 ft. Max .2 m+ V 2 Minimum Maximum V1 + V2 Minimum H1 + H2 Maximum Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Removing Non-combustible Facing Mate- rial Assembly Appliance PreparationSecuring and Leveling the Appliance Attaching Non-combustible Facing Material Installing Non-combustible Facing MaterialAssembly of Vent Sections DVP Pipe Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Roof Pitch Min. Ft Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Electrical InformationDetail a Romex Connector Junction Box InstallationFacing Material FinishingFinishing Requirements Appliance Setup Positioning the Logs StepLOG #1 SRV750-706 TWO LOG #2 SRV569-705 LOG #3 SRV2012-161LOG #4 SRV2012-162 LOG #5 SRV2012-163 LOG #6 SRV2012-164LOG #7 SRV2012-165 Final Step LOG #8 SRV2012-166Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksReplacing Light Bulb Doors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters DVP vent components Vent Components DiagramsHorizontal Termination Cap Wall Shield Firestop Heat ShieldHorizontal Termination Cap Kit Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm 127 mm 302 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mm13-3/4 13-7/8 352 mm 349 mm Cap Shield Flashing 13-7/8 352 mm 241 mmDVP-TVHW Log Set Assembly Service PartsBeginning Manufacturing Date Sept Ending Manufacturing DateService Parts List StockedAt Depot Be ordered from an authorized dealer Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information
Related manuals
Manual 26 pages 27.68 Kb

36DV specifications

The Heat & Glo LifeStyle 36DV is a state-of-the-art gas fireplace designed for modern living spaces. This model stands out for its seamless blend of aesthetics, performance, and efficiency. With its sleek design and innovative technologies, the LifeStyle 36DV redefines how people experience warmth and ambiance in their homes.

One of the standout features of the LifeStyle 36DV is its powerful heating capability. This direct vent gas fireplace efficiently circulates warm air throughout the room while maintaining optimal energy usage. With an impressive heating output, it can effectively warm spaces of varying sizes, making it suitable for both large living areas and cozy nooks.

The LifeStyle 36DV is engineered with advanced gas technology. The fireplace utilizes a unique ignition system that ensures reliable starts and consistent performance. This system not only enhances ease of use but also increases safety, minimizing any risks associated with traditional ignition methods.

Additionally, the fireplace is equipped with a dynamic, glass-front design that maximizes the viewing area of the flames. With a variety of media options available, including traditional logs and modern glass media, homeowners can customize the look and feel of their fireplace to match their unique style. The LifeStyle 36DV can serve as a focal point in any room, providing both warmth and visual appeal.

Another noteworthy characteristic of the LifeStyle 36DV is its intuitive control system. With the ability to operate via remote control, wall switch, or smartphone app, adjusting the fireplace's settings has never been easier. Users can effortlessly change the flame height, control fan speed, and set timers, allowing for a personalized experience tailored to individual preferences.

The energy efficiency of the LifeStyle 36DV also cannot be overlooked. This fireplace is designed to meet stringent environmental standards, providing homeowners with a cost-effective heating solution that doesn't compromise on style. By utilizing innovative insulation and venting technology, the LifeStyle 36DV keeps the warmth inside where it belongs.

In summary, the Heat & Glo LifeStyle 36DV is a remarkable gas fireplace offering a perfect combination of modern technology and traditional warmth. With its stylish design, powerful heating capabilities, customizable aesthetics, and user-friendly controls, it stands out as a premier choice for homeowners looking to enhance their living spaces. Whether for cozy family gatherings or romantic evenings, the LifeStyle 36DV provides an inviting atmosphere that is hard to match.