Heat & Glo LifeStyle 36DV owner manual Installing Vent Pipe, Assembly of Vent Sections DVP Pipe

Page 22

8 Installing Vent Pipe

A. Assembly of Vent Sections (DVP Pipe)

WARNING

Do not mix pipe, fittings or joining methods from different manufacturers.

WARNING

Fire Risk

Exhaust Fumes Risk

Impaired Performance of Appliance

• Overlap pipe slip sections at least 1-1/2 inches.

Use pilot holes for screws.

Screws must not exceed one inch long.

Pipe may separate if not properly joined.

Attaching Vent to the Firebox Assembly

To attach the first pipe section to the collars, slide the male end of the inner vent of the pipe section over the inner collar on the firebox assembly. At the same time, slide the outer flue over the outer collar on the appliance. Push the pipe section into the appliance collar until all the lances (see Figure 8.1) have snapped in place. Tug slightly on the sec- tion to confirm it has completely locked into place.

Commercial, Multi-family (Multi-level exceeding two stories), & High-Rise Applications

For Installation into Commercial, multi-family (multi-level ex- ceeding two stories) or high-rise applications: All pipe joints must be sealed with high temperature silicone, including the slip section that connects directly to the horizontal termina- tion cap.

Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections. See Figure 8.1

Only outer pipes are sealed. Do not seal the inner flue. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated.

Note: The end of the pipe sections with the lances/tabs on it will face toward the appliance.

WARNING

Fire Risk Explosion Risk

If slip section seals are broken during the removal of the termination cap, gas will leak and a fire or explosion may occur.

Do not break silicone seals on slip sections.

Assembling Pipe Sections

Insert the inner flue of section A into the flared inner flue of section B.

Start the outer flue of section A over the outer flue of section B (see Figure 8.2). Note: The end of the pipe sections with the lances/tabs on it will face towards the appliance. Once both inner and outer flues are started, press section A onto section B firmly until all lances have snapped into place. Check to make sure they have snapped together (see Fig- ure 8.3) and the seams are not aligned (see Figure 8.4). Tug slightly on section A to confirm it has completely locked into place. It is acceptable to use screws no longer than 1 inch to hold outer pipe sections together. If predrilling holes, do NOT penetrate inner pipe.

For 90° and 45° elbows that are changing the vent direction from horizontal to vertical, one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1 inch. If predrilling screw holes, do NOT penetrate inner pipe.

High Temperature Silicone Sealant

Commercial, Multi-family (multi-level exceeding two

stories), or High-rise Applications only

Figure 8.1 Lances

A

B

Figure 8.2

Figure 8.3

22

Heat & Glo • Escape-36DV2012-900 • Rev. AA • 04/08

Image 22
Contents What to do if you smell gas Model Escape-36DVHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections Hearth ExtensionVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 + V2 Minimum MaximumTop Vent Vertical Termination No Elbow V1 = 40 ft. Max .2 m Flue Restrictor Instructions+ V 2 Minimum Maximum Top Vent Vertical Termination Three Elbows V1 + V2 Minimum H1 + H2 MaximumWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblySecuring and Leveling the Appliance Installing Non-combustible Facing Material Attaching Non-combustible Facing MaterialAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections DVP Pipe Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Electrical InformationDetail a Junction Box Installation Romex ConnectorFinishing Facing MaterialFinishing Requirements Appliance Setup Step Positioning the LogsLOG #1 SRV750-706 TWO LOG #3 SRV2012-161 LOG #2 SRV569-705LOG #4 SRV2012-162 LOG #6 SRV2012-164 LOG #5 SRV2012-163LOG #7 SRV2012-165 LOG #8 SRV2012-166 Final StepRemoving Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceLighting Appliance IPI Ignition Turn off all electric power to the applianceOn position. The ON/OFF switch may Final inspection byInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceReplacing Light Bulb Inspect Maintenance Tasks Doors, SurroundsReference Materials Appliance Dimension DiagramLocation Inches Millimeters Vent Components Diagrams DVP vent componentsHeat Shield Horizontal Termination Cap Wall Shield FirestopHorizontal Termination Cap Kit 13-3/4 13-7/8 352 mm 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mmRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 127 mm 302 mm Cap Shield Flashing 13-7/8 352 mm 241 mmDVP-TVHW Beginning Manufacturing Date Sept Service PartsLog Set Assembly Ending Manufacturing DateStocked Service Parts ListAt Depot Be ordered from an authorized dealer Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 26 pages 27.68 Kb

36DV specifications

The Heat & Glo LifeStyle 36DV is a state-of-the-art gas fireplace designed for modern living spaces. This model stands out for its seamless blend of aesthetics, performance, and efficiency. With its sleek design and innovative technologies, the LifeStyle 36DV redefines how people experience warmth and ambiance in their homes.

One of the standout features of the LifeStyle 36DV is its powerful heating capability. This direct vent gas fireplace efficiently circulates warm air throughout the room while maintaining optimal energy usage. With an impressive heating output, it can effectively warm spaces of varying sizes, making it suitable for both large living areas and cozy nooks.

The LifeStyle 36DV is engineered with advanced gas technology. The fireplace utilizes a unique ignition system that ensures reliable starts and consistent performance. This system not only enhances ease of use but also increases safety, minimizing any risks associated with traditional ignition methods.

Additionally, the fireplace is equipped with a dynamic, glass-front design that maximizes the viewing area of the flames. With a variety of media options available, including traditional logs and modern glass media, homeowners can customize the look and feel of their fireplace to match their unique style. The LifeStyle 36DV can serve as a focal point in any room, providing both warmth and visual appeal.

Another noteworthy characteristic of the LifeStyle 36DV is its intuitive control system. With the ability to operate via remote control, wall switch, or smartphone app, adjusting the fireplace's settings has never been easier. Users can effortlessly change the flame height, control fan speed, and set timers, allowing for a personalized experience tailored to individual preferences.

The energy efficiency of the LifeStyle 36DV also cannot be overlooked. This fireplace is designed to meet stringent environmental standards, providing homeowners with a cost-effective heating solution that doesn't compromise on style. By utilizing innovative insulation and venting technology, the LifeStyle 36DV keeps the warmth inside where it belongs.

In summary, the Heat & Glo LifeStyle 36DV is a remarkable gas fireplace offering a perfect combination of modern technology and traditional warmth. With its stylish design, powerful heating capabilities, customizable aesthetics, and user-friendly controls, it stands out as a premier choice for homeowners looking to enhance their living spaces. Whether for cozy family gatherings or romantic evenings, the LifeStyle 36DV provides an inviting atmosphere that is hard to match.