Desa (V)T36N SERIES, (V)T32N, CTDV36NR Product Features, PRE-INSTALLATION Preparation

Page 4

4

PRODUCT FEATURES PRE-INSTALLATION PREPARATION

Location and Space Requirements

PRODUCT FEATURES

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe in- stallation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

This fireplace does not require electricity to operate.

Only the blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the fireplace when framing.

A piezo ignitor and ceramic electrode create spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.

Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas operating unit. It requires approximately 10-20 minutes of operating time before the flame pattern stabilizes.

PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient location for your DESA International direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traf- fic areas, windy or drafty areas, or near furniture or draperies.

Proper clearances must be maintained.

Your fireplace is designed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the back, sides, or top of your fireplace, except where standoff spacers are integrally attached. If stand- off spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5.

If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you main- tain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6.

If recessing into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450ºF (232ºC) heat- resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termina- tion area.

Flush with a wall

Through exterior wall enclosed in a chase

Corner installation

Figure 2 - Common Fireplace Locations

RW

D

If your fireplace is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

FW

Fireplace size

D x FW x RW

 

 

 

 

32"

16 5/8"

34 3/8"

22 1/2"

36"

21 1/8"

41"

29"

Figure 3 - Fireplace Bottom Dimensions

For..com

108661-01D

Image 4
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Installing Horizontal Vent Cap Horizontal Termination Configurations Square TerminationVertical Series 29 minCorner and Alternate Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingFireplace Installation Parts Lists for Venting Kits and ComponentsInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Blower Model BKTInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Remote ReceiverCleaning Glass Door REMOVING/REPLACING Glass DoorRemoving Louver Panels Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoInstalling Logs No and No For Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional Remote Operation Ghrc Series OperationGhrcta Series Operation Tions onOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsAccessories VT32NRB Illustrated Parts BreakdownVT32PRB CHDV32NR Parts List KEY Part Number Description QTYCTDV36NR Not a field Warranty Information

(V)T32N, CTDV36NR, (V)T36N SERIES specifications

The Desa CTDV36NR,(V)T36N and (V)T32N series represent an advanced line of heating appliances designed for efficient and effective home heating. These gas-fired units provide the perfect blend of functionality, aesthetics, and modern technology to meet diverse consumer needs. Renowned for their remarkable durability and compatibility with various home styles, the Desa series is an ideal choice for homeowners seeking reliable heating solutions.

One of the standout features of the Desa CTDV36NR is its ability to deliver radiant heat from a realistic flame, creating a cozy atmosphere in any room. The heating capacity is sufficient for a range of room sizes, ensuring that every corner is warmed efficiently. The units are also equipped with an easy-to-use remote control system, allowing users to adjust settings from a distance for maximum convenience.

The (V)T36N and (V)T32N models feature advanced safety technologies, including automatic shut-off systems and oxygen depletion sensors. These safety features provide peace of mind by ensuring secure operation even in confined spaces. Additionally, the series includes a battery backup option, maintaining functionality during power outages, which enhances its reliability.

Another significant characteristic of the Desa series is its aesthetic versatility. Both models come in various finishes and styles, allowing them to seamlessly integrate into existing interior designs. The high-quality glass front offers a beautiful view of the flames, enhancing ambiance while providing essential warmth.

Efficiency is a key focus in the design of the Desa CTDV series, as they are engineered to optimize fuel usage and reduce utility costs. Many models are equipped with high-efficiency gas burners that result in lower emissions and a reduced carbon footprint, making them an eco-friendlier option for heating.

Easy installation is yet another advantage of the Desa CTDV36NR, (V)T36N, and (V)T32N models. They can be vented through multiple configurations, accommodating a wide range of home layouts. Homeowners appreciate the straightforward installation process, which minimizes disruption and helps them enjoy their new heating system sooner.

In summary, the Desa CTDV36NR, (V)T36N, and (V)T32N series combine cutting-edge technology, safety features, aesthetic appeal, and energy efficiency. These heating solutions exemplify modern design principles while fulfilling the essential function of providing warmth, making them an excellent choice for any home.