REPLACEMENT PARTS

32 SPECIFICATIONS SERVICE HINTS TECHNICAL SERVICE

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA International’s Customer Service Department at 1-866-672-6040.

When calling DESA International, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Customer Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical service web site

at www.desatech.com.

SPECIFICATIONS

 

CHDV32NR

CTDV36NR

 

 

 

(V)T32N(R)

(V)T36N(R)

(V)T32P(R)

(V)T36P(R)

 

 

 

 

 

Btu

12,000/18,000 Btu/hr

18,000/26,000 Btu/hr

11,000/17,000 Btu/hr

17,000/24,000 Btu/hr

 

 

 

 

 

Gas Type

Natural

Natural

Propane/LP

Propane/LP

 

 

 

 

 

Ignition

Piezo

Piezo

Piezo

Piezo

 

 

 

 

 

Manifold Pressure

3.5" w.c.

3.5" w.c.

10.0" w.c.

10.0" w.c.

 

 

 

 

 

Minimum Inlet Supply Pressure

5.5" w.c.

5.5" w.c.

11.0" w.c.

11.0" w.c.

 

 

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

 

 

Fireplace (Actual size of

 

 

 

 

firebox. Measurements do not

32 1/4" x 34 1/2" x 16 5/8"

36" x 41" x 21 1/8"

32 1/4" x 34 1/2" x 16 5/8"

36" x 41" x 21 1/8"

include nailing flanges or

819 x 876 x 422 mm

914 x 1041 x 537 mm

819 x 876 x 422 mm

914 x 1041 x 537 mm

standoffs).

 

 

 

 

Carton

33 1/2" x 37 1/2" x 17 1/2"

38" x 44" x 22"

33 1/2" x 37 1/2" x 17 1/2"

38" x 44" x 22"

 

851 x 953 x 445 mm

965 x 1118 x 559 mm

851 x 953 x 445 mm

965 x 1118 x 559 mm

 

 

 

 

 

Weight, lbs/kg*

 

 

 

 

Fireplace

80 lbs/36 kg

120 lbs/55 kg

80 lbs/36 kg

120 lbs/55 kg

Shipping

83 lbs/38 kg

123 lbs/56 kg

83 lbs/38 kg

123 lbs/56 kg

 

 

 

 

 

*For refractory lined models add 45 pounds for 32" models and 60 pounds for 36" models.

For..com

108661-01D

Image 32
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationVent Pipe Connections Installing Horizontal Vent Cap Horizontal Termination Configurations Square TerminationVertical Series 29 minCorner and Alternate Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingFireplace Installation Parts Lists for Venting Kits and ComponentsInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Blower Model BKTInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Remote ReceiverCleaning Glass Door REMOVING/REPLACING Glass DoorRemoving Louver Panels Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoInstalling Logs No and No For Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional Remote Operation Ghrc Series OperationGhrcta Series Operation Tions onOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveReplacement Parts Service HintsTechnical Service SpecificationsAccessories VT32PRB CHDV32NR Illustrated Parts BreakdownVT32NRB Parts List KEY Part Number Description QTYCTDV36NR Not a field Warranty Information

(V)T32N, CTDV36NR, (V)T36N SERIES specifications

The Desa CTDV36NR,(V)T36N and (V)T32N series represent an advanced line of heating appliances designed for efficient and effective home heating. These gas-fired units provide the perfect blend of functionality, aesthetics, and modern technology to meet diverse consumer needs. Renowned for their remarkable durability and compatibility with various home styles, the Desa series is an ideal choice for homeowners seeking reliable heating solutions.

One of the standout features of the Desa CTDV36NR is its ability to deliver radiant heat from a realistic flame, creating a cozy atmosphere in any room. The heating capacity is sufficient for a range of room sizes, ensuring that every corner is warmed efficiently. The units are also equipped with an easy-to-use remote control system, allowing users to adjust settings from a distance for maximum convenience.

The (V)T36N and (V)T32N models feature advanced safety technologies, including automatic shut-off systems and oxygen depletion sensors. These safety features provide peace of mind by ensuring secure operation even in confined spaces. Additionally, the series includes a battery backup option, maintaining functionality during power outages, which enhances its reliability.

Another significant characteristic of the Desa series is its aesthetic versatility. Both models come in various finishes and styles, allowing them to seamlessly integrate into existing interior designs. The high-quality glass front offers a beautiful view of the flames, enhancing ambiance while providing essential warmth.

Efficiency is a key focus in the design of the Desa CTDV series, as they are engineered to optimize fuel usage and reduce utility costs. Many models are equipped with high-efficiency gas burners that result in lower emissions and a reduced carbon footprint, making them an eco-friendlier option for heating.

Easy installation is yet another advantage of the Desa CTDV36NR, (V)T36N, and (V)T32N models. They can be vented through multiple configurations, accommodating a wide range of home layouts. Homeowners appreciate the straightforward installation process, which minimizes disruption and helps them enjoy their new heating system sooner.

In summary, the Desa CTDV36NR, (V)T36N, and (V)T32N series combine cutting-edge technology, safety features, aesthetic appeal, and energy efficiency. These heating solutions exemplify modern design principles while fulfilling the essential function of providing warmth, making them an excellent choice for any home.