Desa CF26PTA Optional Mantel Installation, Removing Brick Liner Retainer, Assembling Trim

Page 11

INSTALLATION

Continued

NOTICE: If your installation does not meet the minimum clear- ances shown, you must do one of the following:

raise the mantel to an accept- able height

remove the mantel

Note: All vertical

Mantel Shelf

 

 

 

 

measurements

10"

 

 

 

are from top

 

 

 

8"

 

 

 

of fireplace

 

 

 

 

 

 

 

opening to

6"

 

 

 

 

 

 

bottom of

2 1/2"

 

 

 

 

 

 

mantel shelf.

 

 

 

 

Minimum Non-

 

 

 

 

Combustible

 

 

 

 

Material

13"

16"

19"

21"

 

 

 

 

 

 

6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.

7.Repeat steps 1 through 6 for other corner.

8.Set trim assembly aside for later installation.

Slot

Set Screws

Top

 

 

Trim

Shim

Mitered

Edge

 

Side

Adjusting Trim

Plate

Slot

Figure 10 - Assembling Trim

OPTIONAL MANTEL INSTALLATION

Note: Refer to instructions provided with the man- tel for assembly instructions. Refer to instructions below for system installation. If using blower ac- cessory (see Accessories, page 32), see installation instructions on pages 12 through 15.

1.Choose location for fireplace and install gas supply line.

2.Remove screen from fireplace by removing screws in each end of screen rod (see Figure 11). Hold screen rod cover while removing five hex head screws underneath hood (see Figure 12). Carefully lift and pull out hood (see Figure 13, page 12).

Figure 9 - Minimum Mantel Clearances

for Built-In Installation

REMOVING BRICK LINER

RETAINER

1.Using Phillips screw driver, remove 2 screws attaching brick liner retainers to vertical sides.

2.Remove brick liner retainers and discard. Replace 2 screws into vertical sides.

ASSEMBLING TRIM

(Trim shipped with mantel)

1.Remove packaging from three pieces of trim.

2.Locate two adjusting plates with set screws, and two shims in the hardware packet.

3.Align shim under adjusting plate as shown in Figure 10.

4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 10).

5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 10).

Figure 11 - Removing Screen

Hood

Screen Rod

Cover

Screw

Figure 12 - Removing Hood Screws

113896-01A

www.desatech.com

11

Image 11
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Local CodesPiezo Ignition System Product FeaturesSafety Pilot Product IdentificationConfined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Fireplace InstallationCheck GAS Type Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Mantel Clearances for Built-In InstallationTrim shipped with mantel Optional Mantel InstallationRemoving Brick Liner Retainer Assembling TrimRemoving Hood Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In Installation Installation Items Needed Connecting to GAS SupplyNatural From Connecting Fireplace to GAS SupplyPropane/LP KPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 PsigPressure Testing Heater GAS Connections Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat Control Operation Manual Lighting ProcedureInspecting Burners To Turn OFF GAS To ApplianceMain Burner Cleaning MaintenanceBurner Flame Pattern Burner Primary AIR HolesBlow air into the primary air holes on the injector holder CabinetObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Technical Service SpecificationsReplacement Parts Service HintsModels CF26PTA and CF26NTA Illustrated Parts BreakdownParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Thermostatically Controlled Blower KIT GA3450T AccessoriesParts Central Equipment Shutoff Valve GA5010Information Video Cleaning KIT GCKCabinet Mantel with BUILT-IN Hearth Base Cabinet Mantel with Full Hearth Base113896-01A 113896-01A Limited Warranty VENT-FREE GAS BAY Front Fireplace Warranty InformationKeep this Warranty