Desa CF26PTA installation manual Troubleshooting, Observed Problem Possible Cause Remedy

Page 23

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode not con-

1.

Reconnect ignitor cable

there is no spark at ODS/pilot

 

nected to ignitor cable

2.

Free ignitor cable if pinched

 

2.

Ignitor cable pinched or wet

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor

 

 

 

 

to base panel of log set. Nut is

 

 

 

 

located behind base panel

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned

6.

Replace pilot assembly

 

 

wrong

7.

Replace pilot assembly

 

7.

Ignitor electrode broken

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equip- ment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when in- stalled

5.Depleted gas supply (propane/ LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down con- trol knob. Repeat igniting op- eration until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Clean- ing and Maintenance, page

21)or replace ODS/pilot as- sembly

7.Replace gas control

113896-01A

www.desatech.com

23

Image 23
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Local CodesPiezo Ignition System Product FeaturesSafety Pilot Product IdentificationConfined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Fireplace InstallationCheck GAS Type Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Mantel Clearances for Built-In InstallationTrim shipped with mantel Optional Mantel InstallationRemoving Brick Liner Retainer Assembling TrimRemoving Hood Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In Installation Installation Items Needed Connecting to GAS SupplyNatural From Connecting Fireplace to GAS SupplyPropane/LP KPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 PsigPressure Testing Heater GAS Connections Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat Control Operation Manual Lighting ProcedureInspecting Burners To Turn OFF GAS To ApplianceMain Burner Cleaning MaintenanceBurner Flame Pattern Burner Primary AIR HolesBlow air into the primary air holes on the injector holder CabinetObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Technical Service SpecificationsReplacement Parts Service HintsModels CF26PTA and CF26NTA Illustrated Parts BreakdownParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Thermostatically Controlled Blower KIT GA3450T AccessoriesParts Central Equipment Shutoff Valve GA5010Information Video Cleaning KIT GCKCabinet Mantel with BUILT-IN Hearth Base Cabinet Mantel with Full Hearth Base113896-01A 113896-01A Limited Warranty VENT-FREE GAS BAY Front Fireplace Warranty InformationKeep this Warranty