Desa CHDV36NRA Horizontal Termination Configurations, Ground Floor Installation

Page 10

10

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

VENTING INSTALLATION INSTRUCTIONS

Continued

9.Combustible Exterior Wall Only: Slide wall firestop against interior wall surface and attach with screws provided. See Figure 13 for horizontal termination details.

10.Place fireplace into position and shim with noncombustible ma- terial if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly.

WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and main- tained venting system could result in serious injury, property damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

Minimum Pipe

Overlap 11/4"

Direct Vent

Pipe

Wall

Firestop

Maintain 1"

Minimum Air

Space Around

Outer Pipe When

Penetrating a Wall

10 3/4" x 10 3/4"

Framed

Siding Standoff

Screws

High Wind

Termination

Apply Mastic to Outside Edge of Standoff

Installation using cabinet surrounds

Through the wall using round or square termination (up to 12" horizontal pipe)

NOT FOR CORNER INSTALLATION

45° Elbow

Horizontal High

Wind Square

Termination

Adjustable

Pipe 12" Max.

Wall Firestop

Square Termination

Vertical (V)

Horizontal (H)

32 3/4" min.

17" max.

Opening

Exterior Wall with Vinyl Siding

45° Elbow

Wall

Firestop

Exterior Portion of Wall

Firestop (Round

Termination Only)

Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: Remember that a horizontal run of venting must have a 1/4" rise for every 12" of run toward the termination.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

Horizontal

Round

Termination

Round Termination

(Kit 01491 for V36 Series Kit SDHTRK-58 for CHDV Series)

Figure 14 - Horizontal Termination Configuration for Square or Round Terminations

For..com

111252-01A

Image 10
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Ground Floor InstallationCorner Installation Venting with Two 90 Elbo ws Installation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations High Altitude Installation Number DescriptionDesa Elbows Desa Venting AccessoriesDesa Terminations Model BK Installation Fireplace InstallationInstalling Optional Blower Accessories Check GAS TypeModel BKT Installation Blower Wiring DiagramInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver Removing Louver Panels REMOVING/REPLACING Glass DoorRemoving Glass Doors Cleaning Glass Door Installing Rear Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log No Installing Log NoOperating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsRemote Operation Cghrctb Optional HAND-HELDON/OFF Series Models Ghrcb and Cghrctb Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Illustrated Parts Breakdown Parts List CHDV36NRA Description QTY#56 KEY Part Number Description QTY Technical Service Replacement PartsService Hints SpecificationsOwners Registration Form Postage Required Accessories Warranty Information

CHDV36NRA specifications

Desa CHDV36NRA is a robust and innovative heating solution designed to provide optimal comfort for residential and commercial spaces. This versatile unit is specifically engineered to deliver efficient warmth during the colder months while maintaining energy efficiency, making it an ideal choice for homeowners and businesses alike.

One of the main features of the Desa CHDV36NRA is its powerful heating capacity. With a heat output rating suitable for medium to large rooms, this unit ensures that spaces are warmed quickly and uniformly. It operates using natural gas or propane, giving users the flexibility to choose their preferred fuel source based on availability and cost.

Energy efficiency is a key characteristic of the CHDV36NRA. This model is equipped with advanced heating technologies, such as an electronic ignition system, which eliminates the need for standing pilot lights. This not only conserves energy but also enhances safety by reducing the risk of gas leaks. Additionally, the unit boasts a high efficiency rating, allowing users to save on energy bills without sacrificing comfort.

The design of the Desa CHDV36NRA combines functionality with aesthetics. Its sleek and modern appearance allows it to blend seamlessly with various interior styles. The unit is available in different finishes, enabling users to select one that complements their décor. The large viewing window provides an inviting view of the flames, creating a cozy ambiance in any space.

Another notable feature of the CHDV36NRA is its user-friendly controls. The unit comes with a remote control option, allowing users to adjust settings effortlessly from a distance. This convenience is enhanced by programmable thermostats that help maintain desired temperatures while optimizing energy consumption.

Safety is a top priority for the Desa CHDV36NRA. The unit is designed with multiple safety features, including an automatic shut-off system that activates in case of abnormal operation. This ensures peace of mind for users, knowing that their heater is equipped to handle unforeseen situations.

In summary, the Desa CHDV36NRA stands out for its efficient heating capabilities, modern design, and user-friendly features. With a focus on energy conservation and safety, it is an excellent choice for those seeking reliable and effective heating solutions for their spaces. As homeowners and businesses look to improve their heating systems, the Desa CHDV36NRA represents an ideal combination of performance, efficiency, and style.