Desa CHDV36NRA installation manual Corner Installation

Page 11

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

11

VENTING INSTALLATION INSTRUCTIONS

Continued

CORNER INSTALLATION

Recommended Applications:

Corner ground floor installation

Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe)

Basement installation where one foot clearance from ground to termination is possible

 

Required

 

Vertical (V)

Vertical Pipe

Horizontal (H)

*43 1/2" min.

None

30" max.

54 1/2" min.

1 ft.

48" max.

66 1/2" min.

2 ft.

60" max.

78 1/2" min.

3 ft.

84" max.

90 1/2" min.

4 ft.

20' max.

* Ground Floor Corner Venting

Not to Exceed

(H) Limits

Square

Termination

Wall

 

Firestop

45°

 

Elbow

90° Elbow

As Required for (V)

See Chart for Pipe

Section Required

Not to Exceed

(H) Limits

90° Elbow

Wall

Firestop

45° Elbow

Square Termination

12" Minimum

Figure 15 - Horizontal Termination Configuration for Corner Installation Using One 90° Elbow

SNORKEL TERMINATION INSTALLATION

Recommended Applications:

Installations requiring a vertical rise on building exterior

Any installation using snorkel termination to achieve one foot above ground

Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination.

Snorkel

Snorkel

 

Wall

Termination

 

Termination

 

Firestop

90° Elbow

 

 

 

12"

45°

 

 

Minimum

 

 

Elbow

 

 

 

 

12"

 

 

 

Minimum

 

 

 

 

Adequate

 

 

 

Drainage

 

 

Snorkel

Termination

12"

Minimum

Figure 16 - Snorkel Termination Configurations for Below Ground Installation

For morevisit www..com

111252-01A

Image 11
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbo ws Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Number Description High Altitude InstallationDesa Terminations Desa Venting AccessoriesDesa Elbows Check GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Wiring Diagram Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemInstalling Remote Receiver Installing Optional Wall Mount Switch GWMS2Pressure Testing Fireplace Gas Connections Removing Glass Doors REMOVING/REPLACING Glass DoorRemoving Louver Panels Installing Rear Brick Panel Cleaning Glass DoorInstalling Log No Installing Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceON/OFF Series Models Ghrcb and Cghrctb Optional HAND-HELDRemote Operation Cghrctb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Illustrated Parts Breakdown CHDV36NRA Description QTY Parts List#56 KEY Part Number Description QTY Specifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

CHDV36NRA specifications

Desa CHDV36NRA is a robust and innovative heating solution designed to provide optimal comfort for residential and commercial spaces. This versatile unit is specifically engineered to deliver efficient warmth during the colder months while maintaining energy efficiency, making it an ideal choice for homeowners and businesses alike.

One of the main features of the Desa CHDV36NRA is its powerful heating capacity. With a heat output rating suitable for medium to large rooms, this unit ensures that spaces are warmed quickly and uniformly. It operates using natural gas or propane, giving users the flexibility to choose their preferred fuel source based on availability and cost.

Energy efficiency is a key characteristic of the CHDV36NRA. This model is equipped with advanced heating technologies, such as an electronic ignition system, which eliminates the need for standing pilot lights. This not only conserves energy but also enhances safety by reducing the risk of gas leaks. Additionally, the unit boasts a high efficiency rating, allowing users to save on energy bills without sacrificing comfort.

The design of the Desa CHDV36NRA combines functionality with aesthetics. Its sleek and modern appearance allows it to blend seamlessly with various interior styles. The unit is available in different finishes, enabling users to select one that complements their décor. The large viewing window provides an inviting view of the flames, creating a cozy ambiance in any space.

Another notable feature of the CHDV36NRA is its user-friendly controls. The unit comes with a remote control option, allowing users to adjust settings effortlessly from a distance. This convenience is enhanced by programmable thermostats that help maintain desired temperatures while optimizing energy consumption.

Safety is a top priority for the Desa CHDV36NRA. The unit is designed with multiple safety features, including an automatic shut-off system that activates in case of abnormal operation. This ensures peace of mind for users, knowing that their heater is equipped to handle unforeseen situations.

In summary, the Desa CHDV36NRA stands out for its efficient heating capabilities, modern design, and user-friendly features. With a focus on energy conservation and safety, it is an excellent choice for those seeking reliable and effective heating solutions for their spaces. As homeowners and businesses look to improve their heating systems, the Desa CHDV36NRA represents an ideal combination of performance, efficiency, and style.