Desa CHDV36NRA installation manual Venting Installation Instructions, Installation Precautions

Page 7

VENTING INSTALLATION INSTRUCTIONS

Installation Precautions

7

VENTING INSTALLATION INSTRUCTIONS

NOTICE: Read these instructions completely be- fore attempting installation.

These models are tested and approved for use with DESA (direct- vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines:

When venting system terminates horizontally on an outside wall, you must install a standoff if the termination cap is to be in- stalled directly on a combustible finish such as vinyl, wood, stucco, etc.

Never run the vent downward as this may cause excessive tem- peratures which could cause a fire.

Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11).

Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE: Failure to follow these instructions will void the warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

INSTALLATION PRECAUTIONS

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting system (Do not cut or alter vent components)

Installation of any component part not manufactured or ap- proved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serv- ing a separate solid fuel burning appliance. Each direct-vent gas appliance must use a separate vent system. Do not use common vent systems.

WARNING: Vent pipe air space clearances to com- bustibles are 1" on all sides except on the horizontal sections, which require 2" clearances from the top of the pipe. Where the termination cap penetrates a com- bustible wall, 1" air space clearance is required.

For morevisit www..com

111252-01A

Image 7
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbo ws Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Number Description High Altitude InstallationDesa Elbows Desa Venting AccessoriesDesa Terminations Check GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Wiring Diagram Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver Removing Louver Panels REMOVING/REPLACING Glass DoorRemoving Glass Doors Installing Rear Brick Panel Cleaning Glass DoorInstalling Log No Installing Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceRemote Operation Cghrctb Optional HAND-HELDON/OFF Series Models Ghrcb and Cghrctb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Illustrated Parts Breakdown CHDV36NRA Description QTY Parts List#56 KEY Part Number Description QTY Specifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

CHDV36NRA specifications

Desa CHDV36NRA is a robust and innovative heating solution designed to provide optimal comfort for residential and commercial spaces. This versatile unit is specifically engineered to deliver efficient warmth during the colder months while maintaining energy efficiency, making it an ideal choice for homeowners and businesses alike.

One of the main features of the Desa CHDV36NRA is its powerful heating capacity. With a heat output rating suitable for medium to large rooms, this unit ensures that spaces are warmed quickly and uniformly. It operates using natural gas or propane, giving users the flexibility to choose their preferred fuel source based on availability and cost.

Energy efficiency is a key characteristic of the CHDV36NRA. This model is equipped with advanced heating technologies, such as an electronic ignition system, which eliminates the need for standing pilot lights. This not only conserves energy but also enhances safety by reducing the risk of gas leaks. Additionally, the unit boasts a high efficiency rating, allowing users to save on energy bills without sacrificing comfort.

The design of the Desa CHDV36NRA combines functionality with aesthetics. Its sleek and modern appearance allows it to blend seamlessly with various interior styles. The unit is available in different finishes, enabling users to select one that complements their décor. The large viewing window provides an inviting view of the flames, creating a cozy ambiance in any space.

Another notable feature of the CHDV36NRA is its user-friendly controls. The unit comes with a remote control option, allowing users to adjust settings effortlessly from a distance. This convenience is enhanced by programmable thermostats that help maintain desired temperatures while optimizing energy consumption.

Safety is a top priority for the Desa CHDV36NRA. The unit is designed with multiple safety features, including an automatic shut-off system that activates in case of abnormal operation. This ensures peace of mind for users, knowing that their heater is equipped to handle unforeseen situations.

In summary, the Desa CHDV36NRA stands out for its efficient heating capabilities, modern design, and user-friendly features. With a focus on energy conservation and safety, it is an excellent choice for those seeking reliable and effective heating solutions for their spaces. As homeowners and businesses look to improve their heating systems, the Desa CHDV36NRA represents an ideal combination of performance, efficiency, and style.