Desa CHDV36NRA installation manual Venting with Two 90 Elbo ws

Page 12

12

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

VENTING INSTALLATION

INSTRUCTIONS

Continued

HORIZONTAL SYSTEM INSTALLATION USING TWO 90°

ELBOWS

The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.

Venting with Two 90° Elbo ws

Vertical (V)

Horizontal (H1)

Horizontal (H1) +

 

 

 

Horizontal (H2)

45°Elbow

5' min.

2' max.

6' max.

 

6' min.

4' max.

12' max.

 

7' min.

6' max.

18' max.

 

8' min.

8' max.

20' max.

 

20' max.

8' max.

20' max.

 

Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

Venting with Two 90° Elbo ws

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

20' max.

20' max.

45° Elbow

Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows with Termination at 90° with Fireplace

For..com

111252-01A

Image 12
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Ground Floor InstallationCorner Installation Venting with Two 90 Elbo ws Installation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations High Altitude Installation Number DescriptionDesa Venting Accessories Desa ElbowsDesa Terminations Fireplace Installation Installing Optional Blower AccessoriesModel BK Installation Check GAS TypeModel BKT Installation Blower Wiring DiagramInstalling GAS Piping to Fireplace Location Installation Items NeededConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver REMOVING/REPLACING Glass Door Removing Louver PanelsRemoving Glass Doors Cleaning Glass Door Installing Rear Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log No Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOptional HAND-HELD Remote Operation CghrctbON/OFF Series Models Ghrcb and Cghrctb Operating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Illustrated Parts Breakdown Parts List CHDV36NRA Description QTY#56 KEY Part Number Description QTY Replacement Parts Service HintsTechnical Service SpecificationsOwners Registration Form Postage Required Accessories Warranty Information

CHDV36NRA specifications

Desa CHDV36NRA is a robust and innovative heating solution designed to provide optimal comfort for residential and commercial spaces. This versatile unit is specifically engineered to deliver efficient warmth during the colder months while maintaining energy efficiency, making it an ideal choice for homeowners and businesses alike.

One of the main features of the Desa CHDV36NRA is its powerful heating capacity. With a heat output rating suitable for medium to large rooms, this unit ensures that spaces are warmed quickly and uniformly. It operates using natural gas or propane, giving users the flexibility to choose their preferred fuel source based on availability and cost.

Energy efficiency is a key characteristic of the CHDV36NRA. This model is equipped with advanced heating technologies, such as an electronic ignition system, which eliminates the need for standing pilot lights. This not only conserves energy but also enhances safety by reducing the risk of gas leaks. Additionally, the unit boasts a high efficiency rating, allowing users to save on energy bills without sacrificing comfort.

The design of the Desa CHDV36NRA combines functionality with aesthetics. Its sleek and modern appearance allows it to blend seamlessly with various interior styles. The unit is available in different finishes, enabling users to select one that complements their décor. The large viewing window provides an inviting view of the flames, creating a cozy ambiance in any space.

Another notable feature of the CHDV36NRA is its user-friendly controls. The unit comes with a remote control option, allowing users to adjust settings effortlessly from a distance. This convenience is enhanced by programmable thermostats that help maintain desired temperatures while optimizing energy consumption.

Safety is a top priority for the Desa CHDV36NRA. The unit is designed with multiple safety features, including an automatic shut-off system that activates in case of abnormal operation. This ensures peace of mind for users, knowing that their heater is equipped to handle unforeseen situations.

In summary, the Desa CHDV36NRA stands out for its efficient heating capabilities, modern design, and user-friendly features. With a focus on energy conservation and safety, it is an excellent choice for those seeking reliable and effective heating solutions for their spaces. As homeowners and businesses look to improve their heating systems, the Desa CHDV36NRA represents an ideal combination of performance, efficiency, and style.