Desa CHDV42NRA, (V)V42PA(1) High Altitude Installation, Vertical Venting, Number Description

Page 15

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.) High Altitude Installation Parts Lists for Venting Kits and Components for V42 and VV42 Series

15

VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown)

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada).

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orificetoasmallersize.Reduceinput4%foreach1000feetabovesealevel. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V42 AND VV42 SERIES DESA (5/8") Pipe & Vent Kits

Number

Description

P58-6

6" Section Double Wall Pipe, Galvanized

P58-12

12" Section Double Wall Pipe, Galvanized

P58-24

24" Section Double Wall Pipe, Galvanized

P58-36

36" Section Double Wall Pipe, Galvanized

P58-48

48" Section Double Wall Pipe, Galvanized

PA58-712

Adjustable 7"-12" Section Double Wall Pipe, Galva-

 

nized

FPA58-6

6" Duravent Collar to FMI Pipe Adaptor (6" collar/Pipe

 

Section)

DPA58-6

6" FMI Collar to Pipe Duravent Adaptor (6" collar/Pipe

 

Section)

E58-45

45 deg. Elbow, Galvanized

E58-90

90 deg. Elbow, Galvanized

FSE58-45

45 deg. Starter Elbow, Galvanized (Duravent Collar to

 

FMI Pipe)

DSE58-45

45 deg. Starter Elbow, Galvanized (FMI Collar to

 

Duravent Pipe)

VKG-58

Ground Floor Vent Kit

VKB-58

Basement Vent Kit

VKS-58

Snorkel Vent Kit

VKR-58

Roof Vent Kit

VKC-58

Corner Vent Kit

HTK

Horizontal Round Termination Kit

HT-58

Horizontal Round Termination, Galvanized

HTS-58

Horizontal Square Termination, Galvanized

VT-58

Vertical Round Termination, Galvanized

ST-58-14

14" Snorkel Termination, Galvanized

ST-58-36

36" Snorkel Termination, Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6

Roof Flashing - 0 to 6/12 Pitch, Galvanized

RF-58-12

Roof Flashing - 6/12 to 12/12 Pitch, Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff, Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

For morevisit www..com

111906-01B

Image 15
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Venting with One 90 ElbowElbows High Altitude Installation Vertical VentingNumber Description Desa Terminations Desa Venting AccessoriesDesa 5/8 Pipe & Vent Kits Desa ElbowsCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional HAND-HELD Remote Operation Thermostat Series Models Ghrctb and CghrctbON/OFF Series Models Ghrcb and Cghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01B Warranty Information

CHDV42NRA, (V)V42PA(1) specifications

Desa CHDV42NRA and (V)V42PA(1) represent a line of advanced heating solutions that embody efficiency, comfort, and modern technology. Designed to meet the demands of contemporary living spaces, these heating systems integrate advanced engineering with user-friendly features, making them ideal for various residential settings.

The main feature of the Desa CHDV42NRA is its innovative heating efficiency. It utilizes a high-capacity burner system that ensures optimal fuel consumption while delivering rapid warmth. With a heat output of 42,000 BTUs, it is capable of heating large spaces effortlessly. Its design also prioritizes safety, equipped with an automatic shut-off mechanism that engages in abnormal operating conditions. This feature ensures peace of mind for users, knowing they are protected against potential risks.

In terms of technology, the Desa (V)V42PA(1) stands out with its modern thermostat integration. This allows homeowners to set their preferred temperatures easily, enhancing comfort levels while conserving energy. The system can be connected to smart home devices, enabling remote control through smartphone applications. Users can adjust settings, monitor performance, and even schedule heating cycles to fit their daily routines, maximizing efficiency.

Another characteristic worth noting is the dual-fuel capability featured in both models. This flexibility allows users to choose between propane and natural gas, making it adaptable to different fuel sources depending on availability and cost. The versatility contributes to reduced operating costs while ensuring a steady supply of heat, regardless of external conditions.

Ease of maintenance is another aspect where the Desa CHDV42NRA and (V)V42PA(1) excel. With accessible design features, routine checks and upkeep are simplified, reducing downtime and ensuring optimal performance. The aesthetic appeal of these units, with sleek, contemporary designs, means they can blend seamlessly into varied interior decors, enhancing the overall ambiance of the living space.

In conclusion, the Desa CHDV42NRA and (V)V42PA(1) embody a perfect balance of efficiency, technology, safety, and user-friendliness. They are ideal for homeowners looking for reliable heating solutions that adapt to their lifestyle while maintaining an eco-friendly approach. With these models, users benefit from enhanced comfort without compromising on cost-effectiveness or sustainability.