Desa CHDV42NRA, (V)V42PA(1) Venting Installation Instructions, Installation Precautions

Page 7

VENTING INSTALLATION INSTRUCTIONS

Installation Precautions

7

VENTING INSTALLATION INSTRUCTIONS

NOTICE: Read these instructions completely be- fore attempting installation.

These models are tested and approved for use with DESA (direct- vent) pipe components and terminations.

The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.

These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines:

When venting system terminates horizontally on an outside wall, you may install a standoff if the termination cap is to be in- stalled directly on a combustible finish such as vinyl, wood, stucco, etc.

Never run the vent downward as this may cause excessive tem- peratures which could cause a fire.

Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.

Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11).

Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

NOTICE: Failure to follow these instructions will void the warranty.

INSTALLATION PRECAUTIONS

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting system (Do not cut or alter vent components)

Installation of any component part not manufactured or ap- proved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serv- ing a separate solid fuel burning appliance. Each direct-vent gas appliance must use a separate vent system. Do not use common vent systems.

WARNING: Vent pipe air space clearances to com- bustibles are 1" on all sides except on the horizontal sections, which require 2" clearances from the top of the pipe. Where the termination cap penetrates a com- bustible wall, 1" air space clearance is required.

For morevisit www..com

111906-01B

Image 7
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsElbows Vertical Venting High Altitude InstallationNumber Description Desa Terminations Desa Venting AccessoriesDesa 5/8 Pipe & Vent Kits Desa ElbowsCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceThermostat Series Models Ghrctb and Cghrctb Optional HAND-HELD Remote OperationON/OFF Series Models Ghrcb and Cghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01B Warranty Information

CHDV42NRA, (V)V42PA(1) specifications

Desa CHDV42NRA and (V)V42PA(1) represent a line of advanced heating solutions that embody efficiency, comfort, and modern technology. Designed to meet the demands of contemporary living spaces, these heating systems integrate advanced engineering with user-friendly features, making them ideal for various residential settings.

The main feature of the Desa CHDV42NRA is its innovative heating efficiency. It utilizes a high-capacity burner system that ensures optimal fuel consumption while delivering rapid warmth. With a heat output of 42,000 BTUs, it is capable of heating large spaces effortlessly. Its design also prioritizes safety, equipped with an automatic shut-off mechanism that engages in abnormal operating conditions. This feature ensures peace of mind for users, knowing they are protected against potential risks.

In terms of technology, the Desa (V)V42PA(1) stands out with its modern thermostat integration. This allows homeowners to set their preferred temperatures easily, enhancing comfort levels while conserving energy. The system can be connected to smart home devices, enabling remote control through smartphone applications. Users can adjust settings, monitor performance, and even schedule heating cycles to fit their daily routines, maximizing efficiency.

Another characteristic worth noting is the dual-fuel capability featured in both models. This flexibility allows users to choose between propane and natural gas, making it adaptable to different fuel sources depending on availability and cost. The versatility contributes to reduced operating costs while ensuring a steady supply of heat, regardless of external conditions.

Ease of maintenance is another aspect where the Desa CHDV42NRA and (V)V42PA(1) excel. With accessible design features, routine checks and upkeep are simplified, reducing downtime and ensuring optimal performance. The aesthetic appeal of these units, with sleek, contemporary designs, means they can blend seamlessly into varied interior decors, enhancing the overall ambiance of the living space.

In conclusion, the Desa CHDV42NRA and (V)V42PA(1) embody a perfect balance of efficiency, technology, safety, and user-friendliness. They are ideal for homeowners looking for reliable heating solutions that adapt to their lifestyle while maintaining an eco-friendly approach. With these models, users benefit from enhanced comfort without compromising on cost-effectiveness or sustainability.