Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 33).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fire- place, or using compressed air.

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Equipment

Open

Shutoff

 

Valve

 

Propane/LP

Equipment

Supply Tank

Shutoff

 

Valve

 

Gas Valve

Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace

Closed

Figure 33 - Equipment Shutoff Valve

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, pages 26 through 28). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 26).

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

For morevisit www..com

111906-01B

Image 21
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Venting with One 90 ElbowElbows High Altitude Installation Vertical VentingNumber Description Desa 5/8 Pipe & Vent Kits Desa Venting AccessoriesDesa Elbows Desa TerminationsInstalling Optional Blower Accessories Fireplace InstallationModel BK Installation Check GAS TypeBlower Model BKT Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket REMOVING/REPLACING Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Manual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOptional HAND-HELD Remote Operation Thermostat Series Models Ghrctb and CghrctbON/OFF Series Models Ghrcb and Cghrcb Pilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01B Warranty Information

CHDV42NRA, (V)V42PA(1) specifications

Desa CHDV42NRA and (V)V42PA(1) represent a line of advanced heating solutions that embody efficiency, comfort, and modern technology. Designed to meet the demands of contemporary living spaces, these heating systems integrate advanced engineering with user-friendly features, making them ideal for various residential settings.

The main feature of the Desa CHDV42NRA is its innovative heating efficiency. It utilizes a high-capacity burner system that ensures optimal fuel consumption while delivering rapid warmth. With a heat output of 42,000 BTUs, it is capable of heating large spaces effortlessly. Its design also prioritizes safety, equipped with an automatic shut-off mechanism that engages in abnormal operating conditions. This feature ensures peace of mind for users, knowing they are protected against potential risks.

In terms of technology, the Desa (V)V42PA(1) stands out with its modern thermostat integration. This allows homeowners to set their preferred temperatures easily, enhancing comfort levels while conserving energy. The system can be connected to smart home devices, enabling remote control through smartphone applications. Users can adjust settings, monitor performance, and even schedule heating cycles to fit their daily routines, maximizing efficiency.

Another characteristic worth noting is the dual-fuel capability featured in both models. This flexibility allows users to choose between propane and natural gas, making it adaptable to different fuel sources depending on availability and cost. The versatility contributes to reduced operating costs while ensuring a steady supply of heat, regardless of external conditions.

Ease of maintenance is another aspect where the Desa CHDV42NRA and (V)V42PA(1) excel. With accessible design features, routine checks and upkeep are simplified, reducing downtime and ensuring optimal performance. The aesthetic appeal of these units, with sleek, contemporary designs, means they can blend seamlessly into varied interior decors, enhancing the overall ambiance of the living space.

In conclusion, the Desa CHDV42NRA and (V)V42PA(1) embody a perfect balance of efficiency, technology, safety, and user-friendliness. They are ideal for homeowners looking for reliable heating solutions that adapt to their lifestyle while maintaining an eco-friendly approach. With these models, users benefit from enhanced comfort without compromising on cost-effectiveness or sustainability.