Desa (V)V42PA(1) installation manual Parts List, CHDV42NRA Description QTY

Page 35

PARTS LIST

(V)V42NA(1), (V)V42NSA(1), (V)V42NHA(1), (V)V42PA(1) , (V)V42PSA(1), (V)V42PHA(1), CHDV42NRA

35

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

 

 

(V)V42NSA(1)

 

 

 

 

 

 

(V)V42NHA(1)

 

 

 

 

KEY

(V)V42NA(1)

(V)V42PSA(1)

 

 

 

 

NO.

(V)V42PA(1)

(V)V42PHA(1)

CHDV42NRA

DESCRIPTION

 

QTY.

 

 

 

 

 

 

 

1

**

**

**

Firebox Assembly

 

1

2

**

**

**

Face Weldment

 

1

3

108328-01

108328-01

108328-01

Door Assembly

 

1

 

 

 

___

(V and CHDV Models Only)

 

 

 

108328-02

108328-02

Door Assembly (VV Models Only)

 

1

 

 

 

4

108331-01

108331-01

108331-01

Top Louver Assy

 

1

5

108331-02

108331-02

108331-02

Bottom Louver Assy

 

1

6

**

**

**

Fireplace Top

 

1

7

**

**

**

Fireplace Top Insulation

 

1

8

**

**

**

Fireplace Surround

 

1

9

109082-02

109082-01

109082-01

Heat Shield

 

1

10

108778-01

108778-01

108778-01

Log Set

 

1

10-1

109396-01

109396-01

109396-01

Front Log (Log 1)

 

1

10-2

109397-01

109397-01

109397-01

Rear Log (Log 2)

 

1

10-3

109398-01

109398-01

109398-01

Crossover Log (Log 3)

 

1

10-4

109399-01

109399-01

109399-01

Top Log (Log 4)

 

1

10-5

109400-01

109400-01

109400-01

Left Log (Log 5)

 

1

10-6

109401-02

109401-02

109401-02

Right Log (Log 6)

 

1

10-7

109401-01

109401-01

109401-01

Base Log (Log 7)

 

1

11

___

See Below

See Below

Left Refractory Brick Panel

 

1

___

 

12

See Below

See Below

Rear Refractory Brick Panel

 

1

___

 

13

See Below

See Below

Right Refractory Brick Panel

 

1

 

 

14

108374-01

108374-01

108374-01

Burner Base Gasket

 

1

15

108455-01

108455-01

108455-01

Screen Rod

 

1

16

108740-01

108740-01

108740-01

Screen

 

2

17

11418

11418

11418

Push-On Nut

 

2

18

14123

14123

14123

Strain Relief

 

1

19

21171

21171

21171

Gas Knock-Out Cover

 

2

20

24353

24353

24353

Handy Box Assembly

 

1

21

24460

24460

24460

Gas Conduit Assembly

 

1

22

108329-01

108329-01

108329-01

Burner Assembly (Natural Gas)

 

1

 

108329-02

108329-02

___

Burner Assembly (Propane/LP Gas)

 

1

 

 

 

 

 

 

 

(See pages 38 and 39)

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

25487

25487

25487

Lava Rock/Bag Assy

27253

27253

27253

Notice Label

55240

55240

55240

Vent Label

___

___

BKT

Blower Kit

___

___

PCDM-42V

Conversion Kit

 

 

 

 

 

 

1

1

1

1

1

REFRACTORY BRICK PANELS

V42NSA(1)

VV42NSA(1)

CHDV42NRA

VV42NHA(1)

 

 

V42PSA(1)

VV42PSA(1)

V42NHA(1), V42PHA(1)

VV42PHA(1)

DESCRIPTION

QTY

111299-02

111299-01

111302-02

111302-01

Left Refractory Brick Panel

1

111297-02

111297-01

111300-02

111300-01

Rear Refractory Brick Panel

1

111298-02

111298-01

111301-02

111301-01

Right Refractory Brick Panel

1

 

 

 

 

 

 

** Part not available for field replacement.

For morevisit www..com

111906-01B

Image 35
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationElbows Vertical Termination ConfigurationsVenting with One 90 Elbow Number Description High Altitude InstallationVertical Venting Desa Terminations Desa Venting AccessoriesDesa 5/8 Pipe & Vent Kits Desa ElbowsCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemChecking Gas Joints for Propane/LP Gas Fireplace Pressure Testing Fireplace Gas ConnectionsReplace the switch bracket Removing Glass Doors Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No and Log No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceON/OFF Series Models Ghrcb and Cghrcb Optional HAND-HELD Remote OperationThermostat Series Models Ghrctb and Cghrctb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceCHDV42NRA Illustrated Parts BreakdownCHDV42NRA Description QTY Parts ListIllustrated Parts Breakdown KEY Part Number Description QTY Accessories Owners Registration Form Postage Required 111906-01B Warranty Information

CHDV42NRA, (V)V42PA(1) specifications

Desa CHDV42NRA and (V)V42PA(1) represent a line of advanced heating solutions that embody efficiency, comfort, and modern technology. Designed to meet the demands of contemporary living spaces, these heating systems integrate advanced engineering with user-friendly features, making them ideal for various residential settings.

The main feature of the Desa CHDV42NRA is its innovative heating efficiency. It utilizes a high-capacity burner system that ensures optimal fuel consumption while delivering rapid warmth. With a heat output of 42,000 BTUs, it is capable of heating large spaces effortlessly. Its design also prioritizes safety, equipped with an automatic shut-off mechanism that engages in abnormal operating conditions. This feature ensures peace of mind for users, knowing they are protected against potential risks.

In terms of technology, the Desa (V)V42PA(1) stands out with its modern thermostat integration. This allows homeowners to set their preferred temperatures easily, enhancing comfort levels while conserving energy. The system can be connected to smart home devices, enabling remote control through smartphone applications. Users can adjust settings, monitor performance, and even schedule heating cycles to fit their daily routines, maximizing efficiency.

Another characteristic worth noting is the dual-fuel capability featured in both models. This flexibility allows users to choose between propane and natural gas, making it adaptable to different fuel sources depending on availability and cost. The versatility contributes to reduced operating costs while ensuring a steady supply of heat, regardless of external conditions.

Ease of maintenance is another aspect where the Desa CHDV42NRA and (V)V42PA(1) excel. With accessible design features, routine checks and upkeep are simplified, reducing downtime and ensuring optimal performance. The aesthetic appeal of these units, with sleek, contemporary designs, means they can blend seamlessly into varied interior decors, enhancing the overall ambiance of the living space.

In conclusion, the Desa CHDV42NRA and (V)V42PA(1) embody a perfect balance of efficiency, technology, safety, and user-friendliness. They are ideal for homeowners looking for reliable heating solutions that adapt to their lifestyle while maintaining an eco-friendly approach. With these models, users benefit from enhanced comfort without compromising on cost-effectiveness or sustainability.