Desa CD32M(-1)(-2), CD42M, CD36M(-1)(-2) Introduction, For Your Safety, Selecting Location

Page 3

FOR YOUR SAFETY

Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable materials on or near the appliance.

NEVER leave children unattended when a fire is burning in the fireplace.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage, or loss of life. Refer to this manual for assistance or additional information. Consult a qualified installer or local distributor.

CHECK LOCAL CODES BEFORE

INSTALLING THIS FIREPLACE.

INTRODUCTION

Models CD32M series, CD36M series and CD42M are heat circulating gravity direct vent gas fireplaces with sealed combustion chamber. These fireplaces use millivolt gas control valve and millivolt ignition system.

These fireplaces are convertible with the standard setup as natural gas. Conversion may be performed by the O.E.M. mobile home builder or by a qualified service person on-site. If you are uncertain as to what gas your unit is equipped for, pleas check the rating plate located in the interior of the appliance opening or consult your mobile home supplier or your local distributor of DESA/Coleman products.

BEFORE BEGINNING THE INSTALLATION OF THE FIREPLACE, READ THESE INSTRUCTIONS THROUGH, COMPLETELY.

This DESA/Coleman fireplace and its components are safe when installed according to this installation manual. Unless you use DESA/Coleman components, which has been designed and tested for the fireplace system, you may cause a fire hazard.

The DESA/Coleman warranty will be voided by and DESA/Coleman disclaims any responsibility for the following actions:

-2 -

a)Modification of the fireplace, components, doors, blower, fans, air inlet system and damper control.

b)Use of any component part not manufactured or approved by DESA/Coleman in combination with a DESA/Coleman fireplace system.

PROPER INSTALLATION is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces. This fireplace, when installed, must be electrically grounded in accordance with local codes, or in absence of local codes, with the National Electrical Code ANSI/NFPA 70 and CSA C22.2 Canadian electrical code for Canada.

The installation must conform to local codes, or in the absence of local codes, with the national Fuel Gas Code ANSI Z223.1

current installation code CAN/CGA-B149. This appliance complies with ANS Z21.88-2000/CSA 2.22-2000 VENTED GAS FIREPLACE HEATERS.

SELECTING LOCATION

To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines:

The location must allow for proper clearances (see figure 1).

Consider a location were the fireplace would not be affected by drafts, air conditioning ducts, windows or doors.

A location that avoids the cutting of joists or roof rafters will make installation easier.

Figure 1 COMMON FIREPLACE LOCATIONS

Flush installation is recommended where living space is limited.

Projected installation may be ideal for a new addition on an existing finished wall.

Corner installation makes use of a space that may not normally be used and provides a wider and more efficient range for radiant heat transfer.

For more information, visit www.desatech.com

Image 3
Contents REV D Desa InternationalSave this Book Industrial DriveContents Selecting Location For Your SafetyCheck Local Codes Before Installing this Fireplace IntroductionVent Clearances Minimum Clearances to CombustiblesMantel Clearances Vent Termination ClearancesVent Pipe and Termination Clearances Vent Installation Instructions Vent TerminationOffset Elbow Framing Framing DimensionCorner Installation Electrical HOOK-UP and Remote Receiver DiagramGAS Supply Testing GAS Line HOOK-UPGAS Control Valve Sediment Trap SpecificationsPilot Adjustment Pilot AssemblyFor Models CD32M and CD36M Series LOG InstallationGlass Panel Removal LouversDecorative Facing Burner Flame AdjustmentWiring Diagram Burner FlamePage Pilot Orifice Conversion KITFigure a Face Extension for Model CD32M onlyObserved Problem Possible Cause Remedy Illustrated Parts Breakdown Models CD32M and CD36M Series Illustrated Parts Breakdown Model CD42M Description QTY Illustrated Parts ListAccessory and Replacement Parts