VENT PIPE AND TERMINATION CLEARANCES
The final position of your appliance depends on the location of the termination in relation to the clearances that must be observed.
A= 12” (305mm) clearance above grade, veranda, porch, deck or balcony. ***
B= 9” (229mm) clearance in U.S. and 12” (305mm) clearance in Canada to window or door that may be closed.
C= 9” (229mm) clearance in U.S. and 12” (305mm) clearance in Canada to permanently closed window or door that maybe opened.
D= 18” (475mm) vertical clearance to ventilated and 12” (305mm) to unventilated soffit located above the terminal within a horizontal distance of 2 feet (610mm) from the centerline of the terminal.
E= 12” (305mm) clearance below eaves. F= 9” (229mm) clearance to outside corner.
G= 6” (15mm) clearance to inside corner.
H= not to be installed above a meter/regulator within 3 feet (914mm) horizontally from the centerline of the regulator. ***
I= 36” (914mm) clearance in U.S. and 72” (1829mm) in Canada to service regulator vent outlet. ***
J= 12” (305mm) clearance to
K= 36” (914mm) clearance to a mechanical air supply inlet. L= 84” (2134mm) clearance above paved sidewalk or paved driveway located on public property. *
M= 12” (305mm) clearance under veranda, veranda, porch, deck or balcony. **
*vent shall not terminate directly above a sidewalk or paved driveway that is located between two
both dwellings.
**only permitted if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
***as specified in
.