Desa VYGF33PRA, VYGF33NRA, FPVF33NR Actual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3

Page 10

10

INSTALLATION

Built-In Fireplace Installation

INSTALLATION

Continued

BUILT-IN FIREPLACE INSTALLATION FOR MODELS VYGF33PRA & VYGF33NRA

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 20, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

 

 

Framing

 

 

 

 

 

Height

32 3/8"

 

 

33"

Front Width

34

5/

16

"

 

35

1/ "

 

 

 

 

 

 

2

Depth

16

11/

16

"

17

3/ "

 

 

 

 

 

 

4

1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough opening.If installing in a corner, use dimensions shown in Figure 14 for the rough opening. The height is 33" which is the same as the wall opening above.

2.If using blower, install and properly ground GA3555, three- prong 120 volt electrical outlet, in fireplace. Follow instruc- tions included in kit (see Accessories, pages 34 and 35).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Plug electrical cord into electrical outlet installed in step 2.

6.Carefully insert fireplace into rough opening.

7.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, pages 13 and 14.

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).

9.Check all gas connections for leaks. See Checking Gas Con- nections, pages 14 and 15.

10.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).

39 3/8"

27 7/8"

35 1/2" 55 5/8"

Figure 14 - Rough Opening for Installing in Corner (for Models VYGF33NRA & VYGF33PRA only)

Nails or

Wood

Screws

Nailing Flanges

Figure 15 - Attaching Fireplace to Wall Studs (VYGF33PRA Shown)

BUILT-IN FIREPLACE INSTALLATION FOR MODELS FPVF33PR & FPVF33NR

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 20, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

32 3/ "

33"

 

8

 

Front Width

34 5/16"

35 1/2"

Depth

16 11/16"

17 3/4"

17 3/4"

33"

35 1/2"

Figure 13 - Rough Opening for Installing in Wall

WARNING: A qualified electrician must connect electrical wiring to duplex outlet for built-in installa- tion. Follow all local codes.

For..com

105270

Image 10
Contents Qqqq ¢¢¢¢ What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesUnpacking Product FeaturesLocal Codes AIR for Combustion and VentilationUnusually Tight Construction Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupIncluded with Mantel Accessory Installation ClearancesConventional Fireplace Installation Assembling and Attaching Optional Brass TrimPlacing Hearth Base Accessory Against Wall Actual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Gas ConnectionsFPVF33PR Installing Remote Receiver Unit Optional Wireless HAND-HELD RemoteInstalling 9-VOLT Batteries Installing 9-Volt Battery in ReceiverOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Ghrc Series OperationBurner Primary AIR Holes Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerSpecifications Wiring DiagramLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Illustrated Parts Breakdown VYGF33PRAParts List KEY Part Number VYGF33PRA VYGF33NRA Description QTYFirebox VYGF33PRA VYGF33NRA Firebox VYGF33PRA & VYGF33NRA KEY Part Number Description QTYFPVF33PR KEY Part Number FPVF33PR FPVF33NR Description QTY Firebox FPVF33PR FPVF33NR Firebox FPVF33PR & FPVF33NR Accessories WALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch GWMT1 Firebox Perimeter Brass Trim Accessory GA6090Service Hints Replacement PartsTechnical Service Parts Under WarrantyOwners Registration Form Postage Required 105270 Warranty Information

FPVF33NR, VYGF33NRA, VYGF33PRA specifications

Desa VYGF33PRA, VYGF33NRA, and FPVF33NR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. These models stand out due to their advanced features, modern technologies, and reliable characteristics.

The VYGF33PRA and VYGF33NRA variants are characterized by their versatile design, allowing them to seamlessly fit into a variety of settings. They are equipped with high-efficiency heating elements that ensure optimal heat distribution. These models utilize advanced heat exchanger technology, which not only improves efficiency but also minimizes energy consumption. This makes them an eco-friendly choice for those looking to reduce their carbon footprint without sacrificing comfort.

Safety is a top priority with these models, featuring built-in safety mechanisms like overheat protection, tip-over switches, and thermal cut-off features. This ensures that users have peace of mind while operating the units, particularly in child- or pet-friendly environments. Additionally, the user-friendly interface, complete with intuitive controls, allows for easy setting adjustments and temperature monitoring.

The FPVF33NR model also showcases remarkable features that appeal to modern consumers. It incorporates advanced digital technology, allowing for programmable settings and remote control capabilities. Users can easily adjust heating schedules, enhancing convenience and efficiency.

The energy efficiency rating is another highlight of these models. With features like smart thermostats and energy-saving modes, they are designed to minimize energy usage without compromising on performance. This not only helps in reducing utility bills but also aligns with sustainable living practices.

Moreover, these heaters are built to last, featuring durable materials that ensure longevity and reliability. The aesthetic design is appealing, allowing them to complement any interior décor effortlessly.

In conclusion, Desa VYGF33PRA, VYGF33NRA, and FPVF33NR deliver superior heating performance, user-friendly technology, and thoughtful safety features. Their combination of efficiency, durability, and modern design makes them an excellent choice for anyone in need of dependable heating solutions. Investing in these models will not only enhance comfort but also contribute to a more sustainable energy future.