INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall fireplace. Follow all local codes.

WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited, to tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough openings to create the easiest installation. See Built-In Fireplace Installation, pages 10 and 11.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

IMPORTANT: Make sure the fireplace is level. If fireplace is not level, log set will not work properly.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your fireplace. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

ELECTRICAL HOOKUP

(Models GA3700 Series and GA3700T Series

Blower Accessories, and GA3555 Internal

Duplex Kit)

This fireplace accepts a blower assembly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace within reach of a 120 volt grounded electrical outlet. If not, you must install an electrical outlet within reach of fireplace power cord. The GA3555 outlet accessory is used for built-in applications with blower accessory installed.

INSTALLING HOOD

Install hood to top of firebox as shown in Figure 5. Use 3 Phillips screws provided.

Figure 5 - Installing Hood to Firebox

For morevisit www..com

105270

Image 7
Contents What to do if YOU Smell GAS Qqqq ¢¢¢¢Safety Information Table of ContentsOther gases Product IdentificationAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesConventional Fireplace Installation Included with Mantel AccessoryPlacing Hearth Base Accessory Against Wall Actual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Installing LogsFPVF33PR Installing 9-Volt Battery in Receiver Optional Wireless HAND-HELD RemoteInstalling 9-VOLT Batteries Installing Remote Receiver UnitOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureOptional Remote Operation Ghrc Series Operation Inspecting BurnersOptional Blower Operation Pilot Flame PatternMain Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesSpecifications Wiring DiagramLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VYGF33PRA Illustrated Parts BreakdownKEY Part Number VYGF33PRA VYGF33NRA Description QTY Parts ListFirebox VYGF33PRA VYGF33NRA KEY Part Number Description QTY Firebox VYGF33PRA & VYGF33NRAFPVF33PR KEY Part Number FPVF33PR FPVF33NR Description QTY Firebox FPVF33PR FPVF33NR Firebox FPVF33PR & FPVF33NR Accessories Firebox Perimeter Brass Trim Accessory GA6090 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Parts Under Warranty Replacement PartsTechnical Service Service HintsOwners Registration Form Postage Required 105270 Warranty Information

FPVF33NR, VYGF33NRA, VYGF33PRA specifications

Desa VYGF33PRA, VYGF33NRA, and FPVF33NR are innovative heating solutions designed to provide efficient and effective warmth for residential and commercial spaces. These models stand out due to their advanced features, modern technologies, and reliable characteristics.

The VYGF33PRA and VYGF33NRA variants are characterized by their versatile design, allowing them to seamlessly fit into a variety of settings. They are equipped with high-efficiency heating elements that ensure optimal heat distribution. These models utilize advanced heat exchanger technology, which not only improves efficiency but also minimizes energy consumption. This makes them an eco-friendly choice for those looking to reduce their carbon footprint without sacrificing comfort.

Safety is a top priority with these models, featuring built-in safety mechanisms like overheat protection, tip-over switches, and thermal cut-off features. This ensures that users have peace of mind while operating the units, particularly in child- or pet-friendly environments. Additionally, the user-friendly interface, complete with intuitive controls, allows for easy setting adjustments and temperature monitoring.

The FPVF33NR model also showcases remarkable features that appeal to modern consumers. It incorporates advanced digital technology, allowing for programmable settings and remote control capabilities. Users can easily adjust heating schedules, enhancing convenience and efficiency.

The energy efficiency rating is another highlight of these models. With features like smart thermostats and energy-saving modes, they are designed to minimize energy usage without compromising on performance. This not only helps in reducing utility bills but also aligns with sustainable living practices.

Moreover, these heaters are built to last, featuring durable materials that ensure longevity and reliability. The aesthetic design is appealing, allowing them to complement any interior décor effortlessly.

In conclusion, Desa VYGF33PRA, VYGF33NRA, and FPVF33NR deliver superior heating performance, user-friendly technology, and thoughtful safety features. Their combination of efficiency, durability, and modern design makes them an excellent choice for anyone in need of dependable heating solutions. Investing in these models will not only enhance comfort but also contribute to a more sustainable energy future.